Samwon ENG SU-503B User Manual

Advertisement

Quick Links

Model
Temperature & Humidity Range
SU-503B
Humidity(0~100%)
※ Thank you for purchasing Samwon ENG product. The User Manual is
provided for preventing the damage and trouble of product caused by
carelessness and to inform the precise usage. Please keep it in the safe place
and refer to it when you have any doubt during using this product.
1. Function & Name of Parts
1. Function & Name of Parts
1. Function & Name of Parts
1. Function & Name of Parts
uncun
Increase
Main Output
up up up up
dn dn dn dn
Decreas
Display
Current humidity / Setting humidity
Main Output ON/OFF Display
Main Output Display
Setting Button
set set set set
up up up up
Increase Button
dn dn dn dn
Decrease Button
2. Functions
2. Functions
2. Functions
2. Functions
▶ Only for humidity ON/OFF control.
Variation(dIF) 0.1~25.0%,0~300sec delay timer, forward/converse
Selection function
▶ Lock function for installer / Limit function of Set Value
˚ Limit the range of set humidity by users⇒ Set limit function
˚ Hysteresis, delay time, forward/converse selection⇒Lock function
3. 3. 3. 3. Main Output Set Value Change
Main Output Set Value Change
Main Output Set Value Change
Main Output Set Value Change
▶ Supply power to the controller
Display the current humidity.
▶ Press Set button once. Main output set
Hum value in the right picture flashing
▶To change them, press UP & Down Key.
If you press UP/DN longer than 1 sec
Increased or decrease quickly
※ ※ ※ ※ If set Hum limit function
If set Hum limit function
If set Hum limit function
If set Hum limit function
I I I I s working, the setting will be made
s working, the setting will be made
s working, the setting will be made
s working, the setting will be made
within the range. . . .
within the range
within the range
within the range
▶ If you press Set once again,
the set hum will be saved..
Even if switched-off, the set value
will not be deleted..
▶The current hum displayed and
Controller starts to control.
▶Main Output use terminal 4~5.
SAMWON
SAMWON
SAMWON
SAMWON ENG
ENG
ENG
ENG
VAL Automation
Address: No17, Demirchian St., Yerevan 0002, Armenia
Output
Main Relay(OUT1)
Set Button
set
set
set
set
Display
Hum, Installer Setting Button
Setting Value increase button
Setting Value decrease button
<Current Hum>
<Current Hum>
<Current Hum>
<Current Hum>
< < < < Terminals on Back >
Terminals on Back >
Terminals on Back >
Terminals on Back >
O O O O UT1
UT1
UT1
UT1
sensor
sensor
sensor
sensor
( ( ( ( Main
Main) ) ) )
Main
Main
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫
AC
220V
Coil terminal
Coil terminal
Coil terminal
Coil terminal
Devi
Devi
작동
작동
Devi
작동
Devi
작동
기계
기계
기계
기계
ce
ce
ce
ce
SU- - - - 503
SU
SU
SU
503B B B B Control
503
503
Tel: 00374-10-566720
Fax: 00374-10-543448
Terminal 6 is used for OFF terminal
Terminal 6 is used for OFF terminal
Terminal 6 is used for OFF terminal
Terminal 6 is used for OFF terminal
※ ※ ※ ※
S S S S hould not be used for Main Output.
hould not be used for Main Output.
hould not be used for Main Output.
hould not be used for Main Output.
※ ※ ※ ※ A A A A uxiliary output
uxiliary output
uxiliary output( ( ( ( alarm
uxiliary output
alarm
alarm/ / / / timer
alarm
and 10 10 10 10 cycle timer setting
and
cycle timer setting. . . .
and
and
cycle timer setting
cycle timer setting
4. Sensor Connection Method
4. Sensor Connection Method
4. Sensor Connection Method
4. Sensor Connection Method
sensor connection method
▶ Please connect as the right picture
If you connect with the changed
wired or use different type sensor
'Err' to be displayed.
senor wire extension method
▶ it is possible within 100m.
You should use the shield inside
cable, in order to prevent
input noise
▶The humidity sensor is electromagnetic
induction method. It should be
Installed in dry place because
The instruction value may be
changed because of moisture or a
drop of water inside the sensor.
▶The life time of the humidity
sensor is 2 years.
Sensor Input compensation (the current hum is different)
▶ If sensor cable is too long or sensor is old, there will be hum variation.
At that time, use current hum compensation function (rSt).
▶ At the current hum displayed, press set for 3 seconds.
If dIF displayed, release set. In order to move to rSt (hum
compensation), press set several times.
▶ Input the compensation hum by using up&dn.
If you press set for 3 seconds, it will be saved and the current hum
will be compensated.
For example,
Current Humidity
20 %
20 %
5. External & Panel Dimension
5. External & Panel Dimension
5. External & Panel Dimension
5. External & Panel Dimension
35
Power
AC
AC
AC
AC
100~
100~
100~
100~
6. Set Value Limit
6. Set Value Limit
6. Set Value Limit
6. Set Value Limit & Lock function
220V
220V
220V
220V
① It is possible that users cannot change the default setting, by using lock
function.
Item
Setting
LoC
Default
setting
Item
setting
StH
Main
Main
메인
메인
Main
Main
메인
메인
전원
Pow
Pow
Pow
Pow
전원
전원
전원
StL
Control
Control
Controller User Manual
ler User Manual
ler User Manual
ler User Manual
timer) ) ) ) use terminal 7, 8.
timer
timer
use terminal 7, 8.
use terminal 7, 8. R R R R efer to
use terminal 7, 8.
efer to 9 9 9 9 alarm output setting
efer to
efer to
< < < < Terminals on Back >
Terminals on Back >
Terminals on Back >
Terminals on Back >
sensor
sensor
sensor
sensor
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫
① ① ① ① Black
Black ② ② ② ② White
Black
Black
Terminal
Terminal
Terminal
Terminal
sensor
sensor
sensor
sensor
Hum. sensor
Hum. sensor
Hum. sensor
Hum. sensor
SU- - - - 503B
SU
SU
SU
503B
503B
503B
rSt humidity
+ + + +
-5 %
= = = =
+ + + +
10 %
= = = =
PANEL CUT OUT
73.2
77
& Lock function
& Lock function
& Lock function
Description
OFF
Locking off. All function setting possible.
Only locking and setting hum function
ON
possible.
Description
50
Settable high hum value 50
40
Settable low hum value 40
E-mail:
VAL@web.am
URL:
www.val-automation.am
alarm output setting
alarm output setting
alarm output setting
Power
O O O O UT1
UT1
AC
AC
UT1
UT1
AC
AC
( ( ( ( Main
Main
Main
Main) ) ) )
100~
100~
100~
100~
220V
220V
220V
220V
Humidity
Humidity
Humidity
Humidity
sensor
sensor
sensor
sensor
White ③ ③ ③ ③ Shield
White
White
Shield
Shield
Shield
① ① ① ①
② ② ② ②
③ ③ ③ ③
black
black
black
black
white
white
white
white
red
red
red
red
Displayed Hum
15 %
30 %
+0.6
70
0.6
28+
(unit: mm)
Page 1/2