quick guide
overview
A
B C D
2
1
E
F
G
H
specifications
Power supply
Pilot lights (LED)
Protections
Displayed information (4-digit LED display)
Pump output
High level alarm output
Pump alarm output
Maximum current setting
Minimum current setting
Timed dose setting
Limited run time setting
Maximum terminal cross-section
connection diagrams
Terminals
A.
Power supply 230/400V input.
B.
Pump supply output.
C.
High level alarm output.
D.
Pump alarm output.
3
E.
90dB alarm buzzer output.
F.
High level alarm float switch
4
input.
5
G.
Level control input (probes /
float switches).
H.
Current transformer input.
Pilot lights
6
1.
Pump running.
2.
High level alarm.
3.
Overload setting.
4.
Underload setting.
5.
Timer setting.
6.
Pump alarm.
230/400Vac - 50/60Hz
Pump running, High level alarm, Maximum current, Minimum current, Timer, Pump alarm
Overload, Underload, Phase loss, Jammed impeller
Pump consumption, Maximum current, Minimum current, Timer, Alarms, Settings
12A maximum (up to 40A with auxiliary contactor)
5A maximum
5A maximum
Auto - 0.6...40A (trip in 7 s)
OFF - 0.5...40A (trip in 4 s with 20 s starting delay)
OFF - 3 min...24 h
30 s...30 min
4mm² (power) / 2,5mm² (control)
Pump
12A
max.
dimensions
Pump
Pump
12A
12A
max.
max.
TPM6-DRAIN
single-phase basic diagram
(three-phase pump by contactor)
phase loss
active only
Imin > OFF
Pump
12A
max.
ed.1
Need help?
Do you have a question about the TPM6-DRAIN and is the answer not in the manual?
Questions and answers