User and Installation Instructions
SmartVent Range of Extraction Canopies
SV1212, SV1216, SV1220 & SV1224
– LH/LV/CH/CV/RH/RV
IS554 ECN3869

Advertisement

Table of Contents
loading

Summary of Contents for Lincat SV1212

  • Page 1 User and Installation Instructions SmartVent Range of Extraction Canopies SV1212, SV1216, SV1220 & SV1224 – LH/LV/CH/CV/RH/RV IS554 ECN3869...
  • Page 2 Please read the following carefully before using this appliance. Warnings and Precautions Please ensure that all commissioning checks and initial start-up procedures have taken place. This manual should be kept in a safe and accessible place for future reference. This appliance is designed for professional use and must only be operated by qualified personnel. Please ensure that the appliance is serviced regularly by a suitably qualified engineer.
  • Page 3: Section 1 - Technical Data

    SECTION 1 - TECHNICAL DATA SMARTVENT Description Product Code SV1212/16/20/24 Height of Hood (mm) 1200, 1600, 200 & 2400 Width (mm) 1200 Depth (mm) 63·5, 77·2, 91, 104·6 Weight (Kg) 1 ph 230VNAC Voltage Motor Impeller (rpm) 2160 Motor Max Flow Rate (m³/hr) Motor Starting Current (A) 2·33...
  • Page 4: Ductwork Connection

    Four mounting holes for M8 are provided, but additional fixings may be required, dependent on wall/partition structure. 1100 SV1224 SV1212 SV1216 SV1220 2.3.2 MOUNTING – LEFT AND RIGHT MOUNTED FANS If installing a hood with a left or right hand located fan motor, the installer will need to create bespoke fixing holes in the fan mounting panel.
  • Page 5: Electrical Supply And Connection

    Long duct runs (ground floor to second storey roof, for example) may need a second duct-mounted motor. 2.5. ELECTRICAL SUPPLY AND CONNECTION Connection of two electrical supplies is required. Necessary cable entries will be made by the installer. The lights are supplied connected in parallel. A connection to the premises lighting circuit will be required by simple connection into one of the end downlighting LED lamps.
  • Page 6: Operation

    2.6. COMMISSIONING 2.6.1. OPERATION Turn on the power supply at the fan speed control. Run the fan through the range of the controller. If operating over gas appliances, test for the lowest fan setting prior to interlock activation. Check the lights by operating the relevant light switch. These are not dimmable lights. Do not connect to a dimmer switch.
  • Page 7: Section 4 - Component Replacement

    SECTION 4 – COMPONENT REPLACEMENT 4.1. LIGHT REPLACEMENT 1. Disconnect the mains supply. 2. Pull the lamp away from the hood by gripping the edge of the bezel. 3. When the spring becomes exposed, push it back against the lamp body to allow it to come through the hole in the hood.
  • Page 8: Service Information

    • • Serial number Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00. GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights.