FOG FLOW DIRECTION ......................... 14 Nozzle Tamper ............................. 15 Installation, Exchange and Bag reset ....................15 Maintenance ............................16 Reset from Fault condition ........................17 Defects Possible solution ........................17 Warranty .............................. 19 Installation and use manual for OT-U250PP & OT-U500PP - 2 -...
(the choice of the conditions of use in case of robbery will be suggested by your security consultant). Never use different fog fluids or add any other substance into the bags. Do not use or keep charged Orion Technology machines in vehicles and do never transport Orion Technology before 24 hours since it has been shut off.
13. Orion Technology continues to be effective for up to 2 hours without 220V main power thanks to the insulation system which maintains the temperature in the heating system.
The screw in lower left part of bag compartment’s door is longer than the others and its removal activates the tamper output. Installation and use manual for OT-U250PP & OT-U500PP - 5 -...
For section and types of wires, fuses, suitability of materials to installation sites etc.. IF YOU NEED TO REPLACE THE FUSE, USE ONLY FUSE WITH THE FOLLOWING SPECIFICATIONS: CERAMIC BODY FILLED WITH QUARTZ, REF. STD. EN60127-2-3/DIN41660 3,15AH (EXAMPLE OMEGA GT520231) Installation and use manual for OT-U250PP & OT-U500PP - 6 -...
(except for the BLUE one, arm) will stop working. Until when the heating system allows (about 2.30 h) the machine may emit fog. After that time the PCB will switch off automatically. Installation and use manual for OT-U250PP & OT-U500PP - 7 -...
“negative security”, for this reason the disconnection of a wire does not cause activation. So it is necessary to check carefully the reliability of connections and protect the cables to the control panel to avoid the risk of accidental damages. Installation and use manual for OT-U250PP & OT-U500PP - 8 -...
10.1. Example of connection of inputs with outputs of a standard alarm system In the diagram above the control panel, as example, provides to Orion Fogging system power supply between 11 and 14V DC 250 mA max. The ON/OFF output of this alarm is an Open Collector NPN opened when the system is off and it is stably closed to negative as long as the system turned on.
In case of a fault, the FLT LED (FAULT) will switch on. By opening the cylinders door, besides the TPR (TAMPER) turning on, the relay will switch as well. Max power applicable on the outputs is 100mA Installation and use manual for OT-U250PP & OT-U500PP - 10 -...
Example of connection of outputs with balanced inputs of an antitheft In this diagram, by putting a resistance with a value required by the alarm control panel used, in Orion terminal with not used outputs the central will see the correct resistance. After the activation of an output, a pull-down will occur causing the alarm in the corresponding zone.
The symbol of empty bag, has the meaning of “RESERVE” It means that, since the last bag reset the machine consumed at least 85% of the estimated range of the bag. Installation and use manual for OT-U250PP & OT-U500PP - 12 -...
The following guide indicate the suggested fog emission in relation to the number of seconds of shooting set in average condition of temperature, air pressure and humidity. So these are the details for the OT-U250PP: Max. Shooting time per single Shoot: 30 seconds shooting speed: 8.5 cubic meters per second...
2.50 meters (we advise against the installation on the floor). WARNING! After the fog emission and for a few minutes the nozzle is very hot RISK OF BURNS IF TOUCHED by bare hands. Installation and use manual for OT-U250PP & OT-U500PP - 14 -...
Attention: Before opening the side doors, make sure that the alarm control panel is in “service” mode, so that the opening of the “anti-sabotage or tamper” circuit does not cause any alarm Installation and use manual for OT-U250PP & OT-U500PP - 15 -...
Maintenance Orion generators do not require special care however, it is recommended the support of qualified and authorized personnel for periodic annual monitoring, taking into account the following: • Annually verify the functioning of the pump. • Check the air tightness of the circuit and the switch functioning.
The heat exchanger has not yet reached but doesn’t shoot the minimum temperature of shooting, The front GREEN LED flashes wait for the led to stop flashing standard heating time: 60 min. Installation and use manual for OT-U250PP & OT-U500PP - 17 -...
Page 18
The jumper P3 stands in the See the setting mode of the shooting time buzzer does not sound and “RESET” position at paragraph 13 the LEDs do not flash Installation and use manual for OT-U250PP & OT-U500PP - 18 -...
Warranty The warranty of Orion Technology is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine. Not included in the warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin.