  • Page 1 Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Levalarm Gold ® ™ 16633 Foltz Parkway ● Strongsville, OH 44149 USA Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.clark-reliance.com ● sales@clark-reliance.com...
  • Page 2 All units should be inspected upon receipt to ensure that no damage has been incurred during transit. If there is a ® claim due to damage, it should be filed with the carrier immediately. Clark-Reliance Boiler Trim products should be stored in a dry and sheltered area prior to installation.
  • Page 3 4. After checking that all connections are tight and correct, replace the switch cover, as the unit is now ready to be put in operation. ® LEVALARM LAYOUT Boiler Steam Connection Low Water Cutout Level Boiler Water Connection 16633 Foltz Parkway ● Strongsville, OH 44149 USA Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.clark-reliance.com ● sales@clark-reliance.com...
  • Page 4 After performing the blow-down procedure, if the water level does not appear to return to normal promptly, the connecting piping may be partially restricted and need to be cleaned. 16633 Foltz Parkway ● Strongsville, OH 44149 USA Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.clark-reliance.com ● sales@clark-reliance.com...
  • Page 5 1. Any trip or alarm circuits that are actuated by the equipment being blown-down should be bypassed to prevent false ® alarms during the blow-down process. A Clark-Reliance Holding Switch model HS-0 or HS-1 can be used to by-pass the Low Water Cutout to prevent a false trip during the blow-down procedure.
  • Page 6 The meter should indicate an open circuit only when the switch is in the open position. ® 4. If the unit fails to test properly, contact Clark-Reliance for further instructions to adjust the switch mechanism or to obtain authorization to return the unit for factory inspection. If the switch tests OK, return unit to service.
  • Page 7 Teflon based sealant to both sides of the gasket. Lubricate the bolts with a Nickel based high temperature lubricant and torque to requirements in the Installation section. ® Warning: If this equipment is used in a manner not specified by Clark-Reliance , the protection provided by the equipment ®...
  • Page 8 16633 Foltz Parkway ● Strongsville, OH 44149 USA Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828 www.clark-reliance.com ● sales@clark-reliance.com...