Adherium SmartTouch Product Manual

For use only with bevespi aerosphere

Advertisement

Quick Links

SmartTouch
For use only with Bevespi Aerosphere
Product Manual
For customer support,
email support@smartinhaler.com
or call 1 833 3886 9688.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartTouch and is the answer not in the manual?

Questions and answers

Summary of Contents for Adherium SmartTouch

  • Page 1 SmartTouch ™ For use only with Bevespi Aerosphere ™ Product Manual For customer support, email support@smartinhaler.com or call 1 833 3886 9688.
  • Page 2: Table Of Contents

    ™ Terms and Abbreviations Installing or Removing an MDI Setting up Bluetooth Communications ® Delivering a Dose of Medication Reminders Reviewing SmartTouch Sensor Usage Data ™ Manually Uploading Stored Information Reviewing Battery Level Cleaning the SmartTouch Sensor and MDI ™...
  • Page 3 Storage Troubleshooting Servicing Disposal SmartTouch Sensor Intended Use ™ How the SmartTouch Sensor Works ™ Safety and Usage Information Symbols Warranty Specifications FCC Statement Declaration of Conformity...
  • Page 4: Compatible Mdi Devices

    For more information see www.smartinhaler.com. Warnings, Cautions, and Notes Warnings identify actions or situations that could lead to personal injury. Take note of all warnings before using the SmartTouch sensor. ™ Cautions identify actions or situations that could damage the SmartTouch sensor or other ™...
  • Page 5: Smarttouch

    SmartTouch Sensor Components ™ Key: 1. Door latch 2. Reminder LED  3. Reminder button   4. Pair LED   5. Pair button 6. Battery LED   7. Battery button 8. USB port (not used)  Terms and Abbreviations MDI Metered Dose Inhaler.
  • Page 6: Setting Up Bluetooth

      Installation To install the inhaler, open the door of the SmartTouch ™ sensor by pulling the Door Latch. Push the MDI into the SmartTouch™ sensor. Close the door so it clicks into place. Removal To remove the inhaler, pull the Door Latch to open the door of the SmartTouch™...
  • Page 7: Delivering A Dose Of Medication

    Carry out all steps required to use your inhaler according to the instructions. The SmartTouch™ sensor battery status LED will flash green, orange, or red depending on battery status. The flash will occur 3 seconds after the medication actuation is detected.
  • Page 8: Reminders

    24 minutes, until either the prescribed medication dose is taken or the reminder is cancelled. To cancel the reminder, hold down the Reminder Button on the SmartTouch sensor until you hear a ™ beeping sound and the LED flashes red.
  • Page 9 The SmartTouch sensor’s Bluetooth LED will ™ ® flash red if the upload is not successful. Check the SmartTouch™ sensor is within range of the paired smartphone or tablet computer, and ensure that Bluetooth communications enabled. ® Reviewing the Battery Level...
  • Page 10: Sensor And Mdi

    'The SmartTouch sensor is battery-powered ™ and electronic. Do not immerse the SmartTouch ™ sensor in water. Do not use the SmartTouch ™ sensor if it is not in good condition. Storage To help maintain battery capacity, store your SmartTouch sensor below 30°C (86°...
  • Page 11: Servicing

    Ensure that the inhaler is removed from the SmartTouch sensor prior to disposal. ™ EU only: Do not dispose of the SmartTouch sensor ™ as unsorted municipal waste. The SmartTouch ™...
  • Page 12: How The Smarttouch ™ Sensor Works

    Usage data can be uploaded via a wireless Bluetooth connection. ® Safety and Usage Information To ensure your inhaler functions correctly, do not use the SmartTouch sensor with any other MDI or ™ medication than that indicated on the SmartTouch ™ sensor label.
  • Page 13: Symbols

    For hygiene and data integrity reasons, do not use the SmartTouch sensor with more than ™ one patient. Take care to not spill liquids on the SmartTouch ™ sensor or immerse it in water. The SmartTouch sensor does not detect or record ™...
  • Page 14: Specifications

    This warranty maybe voided under the following circumstances: damage to the SmartTouch sensor ™ including dropping, water damage resulting from condensation or immersion, tampering, attempts to service, or other forms of abuse. The SmartTouch sensor warranty expires 4 years from ™...
  • Page 15: Fcc Statement

    Such modifications could void the user’s authority to operate the equipment Declaration of Conformity Adherium (NZ) Ltd declares that this SmartTouch ™ sensor is in compliance with the essential requirements and other relevant provisions of Directive 93/42/EEC.
  • Page 16 Part Number: ND0300 Version: 1 Issue Date: 7 February 2018 © 2018 Adherium (NZ) Ltd. All rights reserved. For patent and trade mark information, including third- party trademarks, refer to www.adherium.com/ip. Bevespi Aerosphere is a trade mark of AstraZeneca AB.