Product Description ® The GlobalSat LM-110H1 is a RF module that based on LoRa technology which provides long-range, low data rate IoT connectivity to sensors, electronic meter reading, geolocation devices, industrial monitoring and control, home and building automation, long range irrigation systems, and all kinds of IoT/ M2M equipments. It can work as the ™...
™ LoRaWAN Configuration Activation of an end-device can be achieved in two ways, either via Over-The-Air Activation (OTAA) when an end-device is deployed or reset, or via Activation By Personalization (ABP) in which the two steps of end-device personalization and activation are done as one step.
communication from the server shortly after the end-device has sent an uplink transmission. Downlink communications from the server at any other time will have to wait until the next scheduled uplink. Bi-directional end-devices with maximal receive slots (Class C): End-devices of Class C have nearly continuously open receive windows, only closed when transmitting.
Page 8
Read MOST-Link mode status Command Description Response: AAT3 P0=? 1-MOST-Link is enabled 0-MOST-Link is disabled Set Operation Mode of LM-130H1 Command Description [parameter]: Range: 1-3, Default=1 1: Mode 1, Normal mode 2: Mode 2, Wake up mode 3: Mode 3, Power saving mode Response: ok ﹣...
Page 9
® Read LoRa MAC of LM-130H1 Command Description ® Response: LoRa MAC of LM-130H1 AAT1 L0=? (16 Bytes) Example, 9B667C111B001B80 Read Model Name Command Description AAT1 L1=? Response: Model name (7 Bytes) Example, LM-130H1/LM-533 ® Read LoRa Firmware Version Command Description Response: Firmware version (16 Bytes) AAT1 L2=?
Page 10
® Set Rx/Tx Frequency of LoRa Channel Command Description [Parameter1]: Rx frequency in KHz from 865000 to 928000 [Parameter2]: Tx frequency in KHz from 865000 to 928000 AAT1 L4=[parameter1],[parameter2] Response: ok ﹣ parameters are valid invalid_param ﹣ one or both parameter are not valid Example, set Rx frequency as 915MHz and Tx frequency as 915MHz...
Page 11
® Set Wakeup Time of LoRa Channel Command Description [Parameter]: Wakeup time from 0 to 9 0=200ms, 1=400ms, 2=600ms, 3=1s, 4=1.5s, 5=2s, 6=2.5s, 7=3s, 8=4s, 9=5s Default=3 AAT1 L6=[parameter] Response: ok ﹣ parameter is valid invalid_param ﹣ parameter is not valid ®...
Page 12
Read LM-130H1’s Role Status Command Description Response: 0 ﹣ Node AAT1 MA=? 1 ﹣ Gateway Send Payload by M.O.S.T. protocol Command Description [Parameter]: Payload value in hexadecimal character (1-99 Bytes). Response: This command would get two responses. The first one responding if the command is valid or not.
Page 13
Send Payload by MOST-Link protocol (LM-130H1 is gateway, MA=1) Command Description [Parameter1]:1/0 1: ACK enable 0: ACK disable ® [Parameter2]:LoRa _MAC ® The LoRa MAC that assigned to get the payload [Parameter3]:payload Payload value in hexadecimal character (1-84 Bytes). Response: This command would get two responses. The first one responding if the command is valid or not.
Page 14
Send Payload by MOST-Link protocol (LM-130H1 is end node, MA=0) Command Description [Parameter1]:1/0 1: ACK enable 0: ACK disable [Parameter2]:payload Payload value in hexadecimal character (1-84 Bytes). Response: This command would get two responses. The first one responding if the command is valid or not.
Page 15
Enable/ disable AES128 Encryption Command Description [Parameter]:1/0 1: Enable AES128 Encryption 0: Disable AES128 Encryption AAT3 A0=[parameter] Response: ok ﹣ parameter is valid invalid_param ﹣ parameter is not valid Read AES128 Encryption Status Command Description Response AAT3 A0=? 1- Enable AES128 Encryption 0- Disable AES128 Encryption Set AES128 Encryption Command...
Page 16
Set Retries Number and Timeout of MOST-Link Command Description [Parameter1]: Retries number of MOST-Link while not getting ACK (0~9) 0=disable, Default=0 [Parameter2]: Timeout of getting ACK (1~255 seconds) Default=3 AAT3 P3=[parameter1],[parameter2] Response: ok ﹣ parameter are valid invalid_param ﹣ one or both parameter are not valid Read Retries Number and Timeout of MOST-Link Command...
Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.