Installation and Operating Data Installation and Operation Manual ® HHP, HHPU, MHP & MHPU Jandy Pumps WARNING FOR YOUR SAFETY - This product must be installed and serviced by authorized per- sonnel, qualified in pool/spa installation. Improper installation and/or operation can create an electrical hazard which can cause serious injury, property damage, or death.
TABLE OF CONTENTS SECTION 7 SECTION 1 Use and Maintenance General Maintenance......8 Safety Information Winterizing the Pump......9 Safety Instructions........4 SECTION 8 SECTION 2 Troubleshooting General Information Troubleshooting........9 Introduction..........5 Description..........5 SECTION 9 Speciality Service SECTION 3 Blocked Impeller........
Water Pik Technologies, Inc. Page 4 SECTION 1. Safety Information 1A. Safety Instructions READ AND FOLLOW THESE SAFETY INSTRUCTIONS! PLEASE SAVE THESE INSTRUCTIONS Do not start pump dry! Running the pump dry for any length of time will cause severe damage and will void the warranty.
Page 5 Jandy™ Pumps SECTION 2. Pool owners should use high speed for vacuuming the pool, quick filtering action, priming the General Information heating system, and to keep up with heavy bathing loads. Spa owners will want to use high speed for 2A.
Water Pik Technologies, Inc. Page 6 Provide access for future service by leaving a The Jandy™ Pump must be connected to at least clear area around the pump. Allow plenty of two separate suction points in the water. A drain space above the pump to remove the lid and and skimmer, two drains spaced apart, two basket for cleaning.
Page 7 Jandy™ Pumps SECTION 5. Caution Electrical Verification & Installation The pump must be permanently connected to a dedicated electrical circuit. No other 5A. Check for Correct Voltage equipment, lights, appliances or outlets may be on the pump circuit. The correct voltage, as specified on the pump nameplate is necessary for proper performance and long motor life.
Water Pik Technologies, Inc. Page 8 SECTION 6. The pump should prime. The time it takes to prime will depend on the elevation and length of Start-up pipe used on the suction supply pipe. See section 4 "Piping Design & Installation" for proper 6A.
Page 9 Jandy™ Pumps Prior to replacing the lid, check for debris loosened and the pump stored indoors. For around the lid o-ring seat, as this will cause air safety, and to prevent entry of contaminants, leaks into the system. Clean the lid o-ring and reinstall all conduit and terminal box covers.
Water Pik Technologies, Inc. Page 10 If there are still air leaks check the suction side The pump is leaking water between the motor piping union. and pump body. a. While the pump is running, try to tighten the a. This is caused by a damaged or failed union.
Page 11 Jandy™ Pumps 9B. Removing the Pump Body HHP Series Turn off the pump. Switch off the circuit breaker Locatings Locatings Pins (4) to the pump motor. Holes (4) Loosen the suction and discharge unions. This Mounting Diffuser Bracket will allow you to move the pump for easy opening.
Page 13 Jandy™ Pumps If the pump is located above water level of the Lubricate (water) the perimeter of the new seals pool, remove the lid and fill the basket with rubber gasket. water before starting the pump. Press the ceramic assembly onto the Impeller. Prior to replacing the lid, check for debris around the lid o-ring seat, as this will cause air Use Windex or alcohol to remove any...
Exploded Views & Replacement Kit properly disconnect the electrical wiring at the Part Numbers pump motor. To order or purchase parts for Jandy Pumps, contact your Follow steps 1-9 of "Removing the Pump nearest Water Pik Technologies Products dealer or distribu- Body."...
Page 16
Water Pik Technologies, Inc. Page 16 To order or purchase parts for Jandy™ Pumps, contact your nearest Water Pik Technologies Products dealer or distributor. If they cannot supply you with what you need, contact the Customer Service Manager at Water Pik Technologies, Inc. 10B.
Water Pik Technologies, Inc. Page 18 SECTION 11. Pump Curves 11A. Jandy™ HHP & HHPU Pump Curves 3.0H HP 2.0H HP/2.5HH PU 1.5H HP/2.0HH PU 1.0H HP/1.5HH PU .75H HP/1.0HH PU Feet Jandy H igh Head Pum ps Head Full Rated (HHP) & U p Rated (HHPU) Flow (GP M )
Page 24
LIMITED WARRANTY ® Thank you for purchasing Jandy pool and spa products. Waterpik Technologies (manufacturer of Jandy products, including Laars ® pool and spa heaters) warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions: •...