ATX TranScend Operation Manual

Hide thumbs Also See for TranScend:
Table of Contents

Advertisement

Quick Links

TranScend
TranScend Chassis
OPERATION MANUAL
www.atxnetworks.com
www.atxnetworks.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TranScend and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATX TranScend

  • Page 1 TranScend TranScend Chassis OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com...
  • Page 2 Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names in this manual are the property of their respective companies.
  • Page 3: Table Of Contents

    5.1.1 System Commands ..........5-1 TranScend Chassis – Operation Manual...
  • Page 4 Contact ATX Networks ........
  • Page 5: Scope

    SCOPE Scope This document describes the user interfaces for TranScend family chassis. The user interfaces include front panel LED, buttons operations, LCD display, Craft Line Interfaces and remote monitoring through SNMP. NOTE: An overcurrent protection device for permanent connection must be included at the site as a building installation requirement.
  • Page 6 CHAPTER 1: SCOPE This page intentionally left blank. TranScend Chassis – Operation Manual...
  • Page 7: Led Display

    1 are within major alarm range. The major alarm is triggered if the monitored level is beyond the high-high or low-low thresholds. Major/High-High Minor/High Amber Nominal Green Minor/Low Amber Major/Low-Low Figure 1: Generic Alarm & LED Table Plug-in LED Definitions TranScend Chassis – Operation Manual...
  • Page 8: High Sensitivity Quad Return Receiver

    Trigger Events Optical power Module temperature Bottom Synthesizer lock state Example #1: The module temperature is normal, but optical power is major low low. The top LED associated with the slot shall be observed as “red”. TranScend Chassis – Operation Manual...
  • Page 9: Stacker

    Example #1: The module temperature is normal, but primary optical power is major low low. The top LED associated with the slot shall be observed as “red”. 2.1.9 AGC EDFA NOTE: The AGC EDFA described in this document applies to the fi rmware release 1.21 or later. TranScend Chassis – Operation Manual...
  • Page 10: Transceiver

    Example #1: The optical input power is at a level that indicates a major alarm, but the rest of the attributes are normal. The top LED associated with the slot shall be observed as “red”. TranScend Chassis – Operation Manual...
  • Page 11: Opto-Stacker

    Example #1: The optical input power is at a level that indicates a major alarm, but the rest of the attributes are normal. The top LED associated with the slot shall be observed as “red”. TranScend Chassis – Operation Manual...
  • Page 12 CHAPTER 2: LED DISPLAY This page intentionally left blank. TranScend Chassis – Operation Manual...
  • Page 13: Pushbutton Operations

    Select to commit the option. Example #1: In the “Gain Setting Menu”, if the cursor is located on the “Sel Ch: 1” line, the channel #1 shall be used for gain adjustment after “Select” button is pressed. TranScend Chassis – Operation Manual...
  • Page 14: Combination Button Operations

    3.1.2 Combination Button Operations The combination button operations are unique to TranScend chassis. Each combination operation is defi ned strictly for their specifi c usage as the following defi nition. UP+DOWN: When pressing and holding the UP+DOWN button simultaneously when traversing the slot menu, the front panel displays current slot number.
  • Page 15: Front Panel Lcd Display

    Menu Tree Structure The TranScend chassis LCD menu is structured into bi-level trees. The top level is system related information and the second level is plug-in related information. The top level contains the menu for second level, but each has its own menu structure.
  • Page 16: Plug-In Menu Tree

    Displays all system related information. Model: Displays the chassis’ model name. HW Ver: Displays the hardware version information of TranScend chassis. SW Ver: Displays the software version information of TranScend chassis. Ser #: Displays the serial number of TranScend chassis.
  • Page 17 Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 2: TranScend High Sensitivity Quad Return Receiver Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications HS Quad Return Rcvr Press “Select” button to go into the plug-in menu.
  • Page 18: Pon Edfa

    Level 1 Level 2 Level 3 Level 4 Greeting Status Laser Temperature (C) Bias (mA) Optical Input (dBm) Optical Output (dBm) Prev Menu Alarm Laser Temperature Optical Input Optical Output Module Temperature Shutoff Prev Menu TranScend Chassis – Operation Manual...
  • Page 19 Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 3: TranScend Pon EDFA Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications PON EDFA Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select”...
  • Page 20: Quad Return Receiver

    Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 4: TranScend Quad Return Receiver Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications Quad Return Rcvr Press “Select” button to go into the plug-in menu.
  • Page 21 Model: Displays the model name of plug-in module. HW Ver: Displays the hardware version information of plug-in module. SW Ver: Displays the software version information of plug-in module. Ser #: Displays the serial number of plug-in module. TranScend Chassis – Operation Manual...
  • Page 22: Destacker Proxy

    Freq Chnl Prev Menu Chassis Temperature(C) Model Hardware Version Software Version Serial Number Prev Menu Proxy Prev Menu Prev Menu Table 5: TranScend Destacker Proxy Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications DeStacker TranScend Chassis – Operation Manual...
  • Page 23 Syn Lock: Displays the alarm state of synthesizer lock status. Press “Right” or “Left” button to cycle through available channels. Rcvr Power: Displays the alarm status of optical receiver power. Module Temp: Displays the alarm status of module temperature. TranScend Chassis – Operation Manual...
  • Page 24: I-Hub Proxy

    Greeting Message InnoTrans Communications iHub Proxy Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select” will bring back to the Destacker menu. The entries in plug-in menu are described as follows: 4-10 TranScend Chassis – Operation Manual...
  • Page 25: Stacker

    Level 4 Greeting Setup Test Point Menu Sel Channel Prev Menu Prev Menu Alarm Synthesizer Lock Optical Power Laser Temperature Module Temperature Prev Menu Optical Optical Power (dBm) Laser Temperature (C) Attn (dB) Prev Menu TranScend Chassis – Operation Manual 4-11...
  • Page 26 Model Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 7: TranScend Stacker Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications Stacker Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select” will bring back to the System menu.
  • Page 27: Optical Switch

    Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 8: TranScend Optical Switch Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications Optical Switch Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select”...
  • Page 28: Optical Switch Switching Criteria

    Forward Receiver Level 1 Level 2 Level 3 Greeting Setup Menu Attn(dB) Save Prev Menu Status Menu Opt Pwr(dBm) Attn (dB) RF Pwr (dBm) Prev Menu Alarm Menu Opt Power Module Temperature Prev Menu 4-14 TranScend Chassis – Operation Manual...
  • Page 29 Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 9: TranScend Optical Switch Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications Forward Rcvr Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select”...
  • Page 30: Rf Switch

    Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 10: TranScend Optical Switch Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications RF Switch Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select”...
  • Page 31: Rf Switch Switching Criteria

    NOTE: The AGC EDFA describes in this document applies to the fi rmware release 1.21 or later. Level 1 Level 2 Level 3 Level 4 Setup Mode Setting Mode Save Prev Menu Gain Setting Gain (steps) Save Prev Menu Attn Setting Attn Save Prev Menu Prev Menu TranScend Chassis – Operation Manual 4-17...
  • Page 32 Temperature(C) Model Hardware Version Software Version Serial Number Prev Menu Prev Menu Table 11: TranScend AGC-EDFA Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications AGC-EDFA Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select” will bring back to the System menu.
  • Page 33 HW Ver: Displays the hardware version information of plug-in module. SW Ver: Displays the software version information of plug-in module. Ser #: Displays the serial number of plug-in module. Prev Menu: Press “Select” will bring the plug-in’s greeting message screen back. TranScend Chassis – Operation Manual 4-19...
  • Page 34: Transceiver

    Laser Power OPin Pwr RF Level Module Temp Prev Menu Chassis Temperature(C) Model Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 12: TranScend Transceiver Front Panel Display Menu Overview 4-20 TranScend Chassis – Operation Manual...
  • Page 35 Save: Press “Right” or “Left” button to cycle between “Yes” or “No”. Press “Select” to commit the selection into NVRAM when “Yes” is selected. The display in bracket refl ects the current NVRAM storage reading. If user presses “Select” when display is “No”, no NVRAM change takes place. TranScend Chassis – Operation Manual 4-21...
  • Page 36 HW Ver: Displays the hardware version information of plug-in module. SW Ver: Displays the software version information of plug-in module. Ser #: Displays the serial number of plug-in module. Prev Menu: Press “Select” will bring the plug-in’s greeting message screen back. 4-22 TranScend Chassis – Operation Manual...
  • Page 37: High Sensitivity Opto-Stacker

    Laser Temp OPout Pwr Module Temp Prev Menu Chassis Temperature(C) Model Hardware Version Software Version Serial Number Prev Menu Prev Menu Prev Menu Table 13: TranScend High Sensitivity Opto-Stacker Front Panel Display Menu Overview TranScend Chassis – Operation Manual 4-23...
  • Page 38 Laser Temp(C): Displays the current reading of laser temperature in Centigrade. OPout Pwr(dBm): Displays the current reading of optical output power in dBm. Gain Resv (dB): Displays the current gain reserve reading in dB. Mode: Displays the current gain mode setting. 4-24 TranScend Chassis – Operation Manual...
  • Page 39: Direct Forward Transmitter (Dfb Tx)

    Tx Fiber Length Length(Km) Save Prev Menu Prev Menu Status Laser Temp(C) Laser Pwr(dBm) TxRF Lvl(dB) Lambda (nm) Tx Attn (dB) Volt (V) Prev Menu Alarm Laser Temp Laser Power TxRF Lvl Mod Temp Prev Menu TranScend Chassis – Operation Manual 4-25...
  • Page 40 Save: Press “Right” or “Left” button to cycle between “Yes” or “No”. Press “Select” to commit the selection into NVRAM when “Yes” is selected. The display in bracket refl ects the current NVRAM storage reading. If user presses “Select” when display is “No”, no NVRAM change takes place. 4-26 TranScend Chassis – Operation Manual...
  • Page 41: Opto-Stacker

    Press “Select” will bring the plug-in’s greeting message screen back. 4.3.14 Opto-Stacker Level 1 Level 2 Level 3 Level 4 Greeting Setup Sel Channel Mode Setting Mode Save Prev Menu Attn Setting Attn(dB) Save Prev Menu Prev Menu TranScend Chassis – Operation Manual 4-27...
  • Page 42 Model HW Ver SW Ver Ser # Prev Menu Prev Menu Prev Menu Table 7: TranScend Stacker Front Panel Display Menu Overview Greeting: Greeting Message InnoTrans Communications OptoStacker Press “Select” button to go into the plug-in menu. Prev Menu: Press “Select” will bring back to the System menu.
  • Page 43 HW Ver: Displays the hardware version information of plug-in module. SW Ver: Displays the software version information of plug-in module. Ser #: Displays the serial number of plug-in module. Prev Menu: Press “Select” will bring the plug-in’s greeting message screen back. TranScend Chassis – Operation Manual 4-29...
  • Page 44 CHAPTER 4: FRONT PANEL LCD DISPLAY This page intentionally left blank. 4-30 TranScend Chassis – Operation Manual...
  • Page 45: Craft Line Interface (Cli)

    Command Structure Similar to the LCD menu, the TranScend chassis Craft Line Interface (CLI) is structured into bi-level trees. The top level is system related information and the second level is plug-in related information. The top level contains the commands for second level, but each has its own command structure.
  • Page 46 Slot 1 (HS-QRRX) SwVer: 2.0-2.0 HwVer: ModelName: TSD-RRX4-HS-EP SerialNum: 25200111 logout: Logs the remote user off and close the current CLI session. This command has no effect on the CLI via front panel console port. TranScend Chassis – Operation Manual...
  • Page 47 Example #1: This example shows that the chassis contains an High Sensitivity Quad Return Receiver in slot 1 and slot 2, 3 and 4 are empty. Transcend[slot-1] >slot Slot 1 - HS-QRRX Slot 2 - Empty Slot 3 - Empty Slot 4 - Empty TranScend Chassis – Operation Manual...
  • Page 48 There is no response returned for this command. To see the download status, user shall use “downloadstatus” command instead. Transcend [slot-1] >download inno inno 192.168.1.137 /tftpboot/vmlinux-initrd.img Reboot: Displays the current reboot state or initiates a system reboot.
  • Page 49 CHAPTER 5: CRAFT LINE INTERFACE (CLI) NOTE: TranScend chassis is confi gured to factory time prior to shipment. It does not make local time adjustment (e.g. daylight saving time) automatically. Hostname: Displays or confi gure the system hostname. Example #1: In this example, user requested to confi gure the hostname “InnoTrans”. And the system indicates the command execution as “Successful”.
  • Page 50: Plug-In Commands

    Transcend [slot-1] >opticalpoweralarm 1 MajorLoLo ModuleTempAlarm: Displays the alarm status of module temperature. Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal. Transcend [slot-1] >ModuleTempAlarm Normal TranScend Chassis – Operation Manual...
  • Page 51: Pon Edfa

    OPinPowerAlarm: Displays the alarm status of optical input power. Example #1: In this example, the module in slot 1 reports the alarm status of optical input power as “MajorLoLo” (e.g. Major alarm with power reading below the low low threshold). TranScend Chassis – Operation Manual...
  • Page 52: Quad Return Receiver

    Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 dB on channel 1. Transcend [slot-1] >attenuation 1 0 (dB) OpticalPowerAlarm: Displays the alarm status of optical receiver power. TranScend Chassis – Operation Manual...
  • Page 53: Destacker Proxy

    Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 dB on channel 1. Transcend [slot-1] >attenuation 1 0.0 (dB) Mode: Displays the frequency channel plan mode. Example #1: In this example, the module in slot 1 reports its frequency channel mode is 2-channel mode. Transcend [slot-1] >mode TranScend Chassis – Operation Manual...
  • Page 54: Stacker

    LaserTempAlarm: Displays the alarm status of laser temperature. Example #1: In this example, the module in slot 1 reports the alarm status of laser temperature as “MajorLoLo” (e.g. Major alarm with power reading below the low low threshold). 5-10 TranScend Chassis – Operation Manual...
  • Page 55: Optical Switch

    +3.0 (dBm) Switch: Displays the optical switch position. Example #1: In this example, the module in slot 1 reports its optical switch position as on primary input. Transcend [slot-1] >switch primary thresholddBm: Display threshold setting. TranScend Chassis – Operation Manual 5-11...
  • Page 56: Forward Receiver

    OpticalPowerDbm: Displays the optical input power reading in dBm. Example #1: In this example, the module in slot 1 reports its optical input power reading on input #1 (p.s. primary optical input). Transcend [slot-1] >OpticalPwerDbm +3.0 (dBm) 5-12 TranScend Chassis – Operation Manual...
  • Page 57 The followings are example of composite command output for Forward Receiver. Info: System SwVer: 1.6-2.f HwVer: ModelName: TSD_SwCntlr SerialNum: 01420070901234 Slot 1 (FwdRcvr) SwVer: 2.f-2.f HwVer: ModelName: TSD-FWRX SerialNum: 01420070901234 Status: Transcend[slot-1] >status Slot 1 (FwdRcvr) ModuleTemp (deg C): TranScend Chassis – Operation Manual 5-13...
  • Page 58: Rf Switch

    Display threshold setting. Example #1: In this example, the module in slot 1 reports its RF switch threshold as 50 dBmV. Transcend [slot-1] > thresholddBmV +50.0 RFPowerAlarm: Displays the alarm status of RF input power. 5-14 TranScend Chassis – Operation Manual...
  • Page 59 The followings are example of composite command output for RF Switch. Info: System SwVer: 1.6-2.f HwVer: ModelName: TSD_SwCntlr SerialNum: 01420070901234 Slot 1 (RF-Switch) SwVer: 2.f-2.f HwVer: ModelName: TSD-RXFSW SerialNum: 01420070901234 Status: Transcend[slot-1] >status Slot 1 (RF-Switch) ModuleTemp (deg C): +25.0 TranScend Chassis – Operation Manual 5-15...
  • Page 60: Agc Edfa

    Example #1: In this example, the module in slot 1 reports its gain control mode. Transcend [slot-1] >gainControl Gain: Displays the gain reading in dB. Example #1: In this example, the module in slot 1 reports its gain reading. 5-16 TranScend Chassis – Operation Manual...
  • Page 61: Transceiver

    The commands in this section are Transceiver specific. ModuleTemp: Displays the module temperature reading in Centigrade. Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade. Transcend [slot-1] >ModuleTempAlarm +21.4 deg. C TranScend Chassis – Operation Manual 5-17...
  • Page 62 Example #1: In this example, the module in slot 1 reports its transmit attenuation reading. Transcend [slot-1] >attenuation +4.9 dB GainOffset: Displays the gain offset reading in steps. Example #1: In this example, the module in slot 1 reports its gain offset reading. Transcend [slot-1] >gainoffset -20 steps 5-18 TranScend Chassis – Operation Manual...
  • Page 63 (e.g. Major alarm with power reading below the low low threshold). Transcend [slot-1] >OPinPowerAlarm MajorLoLo ModuleTempAlarm: Displays the alarm status of module temperature. Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal. TranScend Chassis – Operation Manual 5-19...
  • Page 64: High Sensitivity Opto-Stacker

    OPoutPower: Displays the optical output power reading in dBm. Example #1: In this example, the module in slot 1 reports its optical output power reading. Transcend [slot-1] >OPoutPower -99.0 (dBm) OpticalPowerDbm: displays the optical receiver power in dBm. 5-20 TranScend Chassis – Operation Manual...
  • Page 65 Example #1: In this example, the module in slot 1 reports the alarm status of optical output power as “MajorLoLo” (e.g. Major alarm with power reading below the low low threshold). Transcend [slot-1] >OPoutPowerAlarm 1 MajorLoLo TranScend Chassis – Operation Manual 5-21...
  • Page 66: Direct Forward Transmitter (Dfb Tx)

    Example #1: In this example, the module in slot 1 reports its RF reading. Transcend[slot-1] >LaserRf +0.0 dB Wavelength: Displays the laser wavelength in nanometer. Example #1: In this example, the module in slot 1 reports its laser wavelength. 5-22 TranScend Chassis – Operation Manual...
  • Page 67 Example #1: In this example, the module in slot 1 reports the alarm status of laser power as “MajorLoLo” (e.g. Major alarm with reading below the low low threshold). Transcend [slot-1] >LaserPowerAlarm MajorLoLo LaserRfAlarm: Displays the alarm status of laser RF. TranScend Chassis – Operation Manual 5-23...
  • Page 68: Opto-Stacker

    Transcend [slot-1] >Mode 1 OpticalPowerdBm: Displays the optical input power reading in dBm. Example #1: In this example, the module in slot 1 reports its optical input power #1 reading. Transcend [slot-1] >OpticalPowerdBm 1 -99.0 dBm 5-24 TranScend Chassis – Operation Manual...
  • Page 69 Transcend [slot-1] >LockAlarm 1 Major ModuleTempAlarm: Displays the alarm status of the module temperature. Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal. Transcend [slot-1] >ModuleTempalarm Normal TranScend Chassis – Operation Manual 5-25...
  • Page 70 CHAPTER 5: CRAFT LINE INTERFACE (CLI) This page intentionally left blank. 5-26 TranScend Chassis – Operation Manual...
  • Page 71: Graphical User Interface

    CHAPTER 6: GRAPHICAL USER INTERFACE GRAPHICAL USER INTERFACE Graphical User Interface Starting system software release 4.0 and later, user can view TranScend chassis via popular browsers. The supported browsers are: • Internet Explorer : 11 ® • Mozilla Firefox : 20.0 ®...
  • Page 72: Chassis Alarm Page

    Module Status page. Please see 7.5 Module Status & Alarm and 7.6 Module Provision pages for detail. Chassis Alarm Page This page shows TranScend chassis alarms, available slots, module types, link to individual slot status and provision (only available to selected modules).
  • Page 73: Top Page

    CHAPTER 6: GRAPHICAL USER INTERFACE 6.4.1 Top Page Top half of the page shows module type, module’s Factory Information and Status. 6.4.2 Bottom Page Bottom half of this page shows module alarms TranScend Chassis – Operation Manual...
  • Page 74: System Command Page

    This page allows users to enter and execute system commands. 6.5.1 Configuration Example To configure the sysLocation, in the “sysLocation” input box, enter “Irvine, CA” then click on “Submit” button. Check the “response” session for command process status. TranScend Chassis – Operation Manual...
  • Page 75: Readback Example

    GRAPHICAL USER INTERFACE 6.5.2 Readback Example Click on “Readback” bottom to retrieve configuration status. In this example, click on the “Readback” bottom destined for “Hostname”, “Response” session shows “Thu Oct 23 22:44:02 2014 | Hostname | InnoTrans”. TranScend Chassis – Operation Manual...
  • Page 76 CHAPTER 6: GRAPHICAL USER INTERFACE This page intentionally left blank. TranScend Chassis – Operation Manual...
  • Page 77: User Interface Cross Reference

    .innoTransTranscendModuleLaserEntry.3 Temperature (C) Status: Bias (mA) LaserBias .innoTransTranscendModuleLaserEntry.13 Status: Optical OPinPower .innoTransTranscendModuleLaserEntry.11 Input (dBm) Status: Optical OPoutPower .innoTransTranscendModuleLaserEntry.12 Output (dBm) Alarm: Laser LaserTempAlarm .iTTrancendNotification.10 Temperature Alarm: Optical Input OPinPowerAlarm .iTTrancendNotification.15 Alarm: Optical OPoutPowerAlarm .iTTrancendNotification.16 Output TranScend Chassis – Operation Manual...
  • Page 78: Quad Return Receiver Attributes

    .innoTransTranscendModuleLaserEntry.21 Chassis: ModuleTemp .innoTransTranscendModuleEntry.6 Temperature(C) Stacker Attributes Front Panel SNMP OID SNMP Trap ID Display Alarm: Synthesizer LockAlarm .iTTrancendNotification.20 Lock Alarm: Optical OpticalPowerAlarm .iTTrancendNotification.19 Power Alarm: Laser LaserTempAlarm .iTTrancendNotification.10 Temperature Alarm: Module ModuleTempAlarm .iTTrancendNotification.30 Temperature TranScend Chassis – Operation Manual...
  • Page 79: Optical Switch Attributes

    SNMP Trap ID Display Status: RF RFPower .innoTransTranscendModuleLaserEntry.14 Pwr(dBmV) Status: Switch Switch .innoTransTranscendModuleLaserEntry.20 Setup: ThresholddBmV .innoTransTranscendModuleLaserEntry.23 Threshold(dBmV) Alarm: RF Pwr RFPowerAlarm .iTTrancendNotification.22 Alarm: Module ModuleTempAlarm .iTTrancendNotification.30 Temperature Alarm: Switch SwitchAlarm .iTTrancendNotification.21 Chassis: ModuleTemp .innoTransTranscendModuleEntry.6 Temperature(C) TranScend Chassis – Operation Manual...
  • Page 80: Agc Edfa Attributes

    Status: Fiber FiberLength .innoTransTranscendModuleLaserEntry.25 Length (km) Alarm: Laser LaserTempAlarm .iTTrancendNotification.10 Temperature Alarm: Laser Power LaserPowerAlarm .iTTrancendNotification.11 Alarm: Laser RF LaserRfAlarm .iTTrancendNotification.12 Alarm: Optical Input OPinPowerAlarm .iTTrancendNotification.15 Alarm: Module ModuleTempAlarm .iTTrancendNotification.30 Temperature Chassis: ModuleTemp .innoTransTranscendModuleEntry.6 Temperature(C) TranScend Chassis – Operation Manual...
  • Page 81: High Sensitivity Opto-Stacker

    Status: Gain Control GainControl .innoTransTranscendModuleLaserEntry.8 Mode Status: Attn (dB) Attenuation .innoTransTranscendModuleLaserEntry.19 Status: Fiber Length FiberLength .innoTransTranscendModuleLaserEntry.25 (km) Alarm: Laser LaserTempAlarm .iTTrancendNotification.10 Temperature Alarm: Laser Power LaserPowerAlarm .iTTrancendNotification.11 Alarm: Laser RF LaserRfAlarm .iTTrancendNotification.12 Alarm: Module ModuleTempAlarm .iTTrancendNotification.30 Temperature TranScend Chassis – Operation Manual...
  • Page 82: Opto-Stacker Attributes

    .innoTransTranscendModuleLaserEntry.15 (dBm) Status: Attn (dB) Attenuation .innoTransTranscendModuleLaserEntry.19 Status: Mode Mode .innoTransTranscendModuleLaserEntry.8 Alarm: Laser Temp LaserTempAlarm .iTTrancendNotification.10 Alarm: OptPwr OpticalPowerAlarm .iTTrancendNotification.19 Alarm: OPout Pwr OPoutPowerAlarm .iTTrancendNotification.16 Alarm: Syn Lock LockAlarm .iTTrancendNotification.20 Alarm: Module ModuleTempAlarm .iTTrancendNotification.30 Temp TranScend Chassis – Operation Manual...
  • Page 83: Snmp Enterprise Attributes

    SNMP ENTERPRISE ATTRIBUTES SNMP Enterprise Attributes The following is a list of all the SNMP Enterprise MIB attributes for TranScend chassis. This list is provided as a reference only, please contact ATX Networks for the latest MIB. INNO-TRANS-TRANSCEND-MIB DEFINITIONS ::= BEGIN...
  • Page 84 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “The model name for the device.” ::= { innoTransTranscendSystem 2 } innoTransTranscendSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “The serial number for the device.” TranScend Chassis – Operation Manual...
  • Page 85 “Download image to the target system. The syntax of the parameters is: download username password ftp-server-IP-address filename-includes-full- path If there is no parameters, the download status will be retrieved.” ::= { innoTransTranscendSystem 8 } innoTransTranscendDownloadImageStatus OBJECT-TYPE TranScend Chassis – Operation Manual...
  • Page 86 - mode : MDC/AGC -- Amp - PumpLaserPower - Laser Output Power innoTransTranscendModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF InnoTransTranscendModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION “Transcend module table” ::= { innoTransTranscendEquip 1 } innoTransTranscendModuleEntry OBJECT-TYPE SYNTAX InnoTransTranscendModuleEntry MAX-ACCESS not-accessible TranScend Chassis – Operation Manual...
  • Page 87 STATUS current DESCRIPTION “The software version(s) of the module.” ::= { innoTransTranscendModuleEntry 3 } innoTransTranscendModuleModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “The model name for the module.” ::= { innoTransTranscendModuleEntry 4 } TranScend Chassis – Operation Manual...
  • Page 88 SYNTAX SEQUENCE OF InnoTransTranscendModuleLaserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION “This table contains a set of data for laser elements in the module.” ::= { innoTransTranscendEquip 2 } innoTransTranscendModuleLaserEntry OBJECT-TYPE SYNTAX InnoTransTranscendModuleLaserEntry MAX-ACCESS not-accessible STATUS current TranScend Chassis – Operation Manual...
  • Page 89 “The laser index refering to each laser in the module. The first laser has index of 1.” ::= { innoTransTranscendModuleLaserEntry 1 } itModuleLaserRFdB OBJECT-TYPE SYNTAX HeTenthdB MAX-ACCESS read-only STATUS current DESCRIPTION “RF level for the laser in tenth of dB.” TranScend Chassis – Operation Manual...
  • Page 90 Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION “Gain offset in steps.” ::= { innoTransTranscendModuleLaserEntry 7 } itModuleLaserGainControl OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “Module gain control mode.” ::= { innoTransTranscendModuleLaserEntry 8 } itModuleAmpPumpPower OBJECT-TYPE TranScend Chassis – Operation Manual...
  • Page 91 DESCRIPTION “Laser bias current in mA.” ::= { innoTransTranscendModuleLaserEntry 13 } itModuleRFPower OBJECT-TYPE SYNTAX HeTenthdBmV MAX-ACCESS read-only STATUS current DESCRIPTION “RF power in dBmV.” ::= { innoTransTranscendModuleLaserEntry 14 } itModuleOpticalPowerdBm OBJECT-TYPE SYNTAX HeTenthdBm MAX-ACCESS read-only TranScend Chassis – Operation Manual...
  • Page 92 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “Switch position.” ::= { innoTransTranscendModuleLaserEntry 20 } itModuleMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “Module mode - switch control mode, frequency channel mode, etc.” 8-10 TranScend Chassis – Operation Manual...
  • Page 93 SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION “Frequency channel mode.” ::= { innoTransTranscendModuleLaserEntry 26 } itModuleGainSet OBJECT-TYPE SYNTAX HeTenthdB MAX-ACCESS read-write STATUS current DESCRIPTION “User gain setting in dB.” ::= { innoTransTranscendModuleLaserEntry 27 } TranScend Chassis – Operation Manual 8-11...
  • Page 94 INTEGER { heCommonNominal(1), heCommonHIHI(2), heCommonHI(3), heCommonLO(4), heCommonLOLO(5), heCommonDiscreteMajor(6), heCommonDiscreteMinor(7) notifyAlarmState OBJECT-TYPE SYNTAX HeCommonLogState MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION “The integer object reports the alarm severity of a notification.” ::= { iTTranscendNotificationObjects 3 } notifyModuleIndex OBJECT-TYPE 8-12 TranScend Chassis – Operation Manual...
  • Page 95 ::= { iTTranscendNotification 33 } -- Notification: Module notifLaserTemp NOTIFICATION-TYPE OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState, notifyModuleIndex } STATUS current DESCRIPTION “The notification of laser temperature alarm. There are 4 lasers in the system. The notifyObjectIndex is TranScend Chassis – Operation Manual 8-13...
  • Page 96 The notifyAlarmState indicates the alarm state.” ::= { iTTranscendNotification 14 } notifOPinPower NOTIFICATION-TYPE OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState, notifyModuleIndex } STATUS current DESCRIPTION “The notification of optical input power alarm. The notifyAlarmState indicates the alarm state.” 8-14 TranScend Chassis – Operation Manual...
  • Page 97 “The notification of synthesizer lock alarm” ::= { iTTranscendNotification 20 } notifSwitch NOTIFICATION-TYPE OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState, notifyModuleIndex } STATUS current DESCRIPTION “The notification of switch status alarm” ::= { iTTranscendNotification 21 } notifRFPower NOTIFICATION-TYPE TranScend Chassis – Operation Manual 8-15...
  • Page 98 DESCRIPTION “The compliance statement for SNMP entities for InnoTrans Transcend products.” MODULE -- this module MANDATORY-GROUPS { innoTransTranscendSystemGroup, innoTransTranscendModuleGroup, innoTransTranscendModuleLaserGroup, innoTransTranscendNotificationObjectGroup, innoTransTranscendNotificationGroup ::= { innoTransTranscendMibCompliances 1 } -- Units of Conformance innoTransTranscendSystemGroup OBJECT-GROUP OBJECTS { innoTransTranscendSwVer, 8-16 TranScend Chassis – Operation Manual...
  • Page 99 STATUS current DESCRIPTION “This group consists of objects in InnoTrans Transcend system group.” ::= { innoTransTranscendMibGroups 1 } innoTransTranscendNotificationObjectGroup OBJECT-GROUP OBJECTS { notifyObjectIndex, notifyObjectValue, notifyAlarmState, notifyModuleIndex STATUS current DESCRIPTION “This group consists of objects in InnoTransce Transcend notification objects group.”...
  • Page 100 OBJECT-GROUP OBJECTS { innoTransTranscendSlotState, innoTransTranscendModuleSwVer, innoTransTranscendModuleModel, innoTransTranscendModuleSerial, innoTransTranscendModuleTemp, innoTransTranscendModuleHwVer, innoTransTranscendModuleDisplayName STATUS current DESCRIPTION “This group consists of objects in InnoTrans Transcend module group.” ::= { innoTransTranscendMibGroups 5 } innoTransTranscendModuleLaserGroup OBJECT-GROUP OBJECTS { itModuleLaserRFdB, itModuleLaserTemp, itModuleLaserPowerWt, itModuleLaserPowerdBm, itModuleLaserWavelength, itModuleLaserGainOffset, itModuleLaserGainControl,...
  • Page 101: Service & Support

    San Jose, CA 95138 USA Tel: (408) 227-3400 – press 3 Fax: (408) 227-3403 Email: opticalsales@atxnetworks.com Web: www.atxnetworks.com Warranty Information All of ATX Networks’ products have a 1-year warranty that covers manufacturer’s defects or failures. TranScend Chassis – Operation Manual...
  • Page 102 9001:15 REGISTERED ATX Networks © 2018 ATX Networks 1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Information in this document is subject to change without notice. Tel: 905.428.6068 | Toll Free: 800.565.7488 | support@atxnetworks.com Rev. 08/18 (ANW1202) www.atxnetworks.com...