Air Flow Settings (Xcell 400 Qvi Model Only); Factory Speed Settings (All Xcell 400 Models); Technical Data - Xpelair Xcell 400 QV Installation And Operating Instructions Manual

Mechanical ventilation unit with heat recovery
Table of Contents

Advertisement

6.3 Air flow settings (Xcell 400 QVI model only)

Air flow rates can be changed by a qualified service technician using the control panel shown below. The supply air
Fan speed can be modified independently from the exhaust air Fan speed, between 150-400 m³/h in the „Customer
Settings‟ menu. See the Service Manual for further details.

6.4 Factory speed settings (All Xcell 400 models)

Speed 1: 150 m³/h - Low speed - preferably at night or during periods of absence
Speed 2: 240 m³/h - Normal daytime operation
Speed 3: 400 m³/h - Boost setting for increased air exchange
Note:
When the MVHR is being used with a Manual 2-Speed Switch (Xcell 400 QV model only); only speeds 2 and 3 will
apply.

6.5 Technical data

Voltage / Frequency
Max. current consumption
Power consumption - Speeds 1, 2, 3
Air flow rate - Speeds 1, 2, 3
Air flow rate at 100 Pa Static Pressure
Protection category
Max. ambient temperature
Dimensions (without ducting) - W x H x D
Weight of MVHR
Duct connections
Condensate drain tube connections
Filter class
Efficiency of Heat Exchanger
Sound pressure level (measured at a distance of 3m) - Speeds 1, 2, 3
13
Technical data
Units
Specification
V / Hz
~ 220-240V / 50-60 Hz
A
2.0
W
35/85/190
m³/h
150/250/350
m³/h
410
IP
20
°C
50
mm
750 x 725 x 469
Kg
34
mm
150
mm
20
-
G4
%
Up to 91%
dB (A)
29/34/44

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xcell 400 qvwXcell 400 qvi