Mini Heki S
7

Installing the Mini Heki S

Supplementary to fig. 4
The scope of delivery contains a mounting frame, which is suitable for roof
thicknesses of 23–42 mm or 43–60 mm:
 Roof thicknesses 23–42 mm: Item no. 9104100289
 Roof thicknesses 43–60 mm: Item no. 9104100290
➤ Measure your roof thickness W.
➤ Shorten the sleeves to size H (see table).
➤ Use the screws with appropriate lengths (see table).
See fig. 5
➤ Check that the roof light has sufficient space around (approx. 1 to 2 mm)
it in the roof opening.
See fig. 6
➤ Clean the roof opening in the mounting area.
See fig. 7
NOTICE!
A
Observe the instructions of the sealant manufacturer.
➤ Seal the mounting frame with a flexible non-hardening sealing compound
(e.g. Sika - Lastomer-710).
See fig. 8
➤ Observe the direction of travel when installing.
➤ Place the outer frame in the middle of the roof opening.
See fig. 9
➤ Install the mounting frame.
➤ Tighten the screws 10 minutes after installation.
See fig. 0
➤ Install the fastening clips on the inner frame at the specified distances.