Advantor ADVANTAGE PLUS Installation Instructions Manual

Base module

Advertisement

Grade A and B Central Station Burglary, Grade A Proprietary Burglary,
Grade A Local Burglary, Grade A Police Station Connected Burglary,
Central Station Fire, Household Fire, Household Burglary, and
Combination Household Fire & Burglary Systems
See the Advantage plus Service Manual (P/N 09820460) for operational theory and service procedures.
See the SONICS Database Management Manual (P/N 09820426) for options programming procedures.
GLOSSARY OF ADVANTAG E plus TERMS
Access Module - Access Modules are Base Module add-on units that
provide facility access control. Each Access Module controls up to
four facility doors, provides ten general purpose alarm loops and six
auxiliary outputs. The Advantage plus Base Module can interface and
control up to seven Access Modules.
Advantor Audio Sensor - An audio sensing device capable of
receiving audio and reporting sounds to an audio detection circuit for
audio detection alarm monitoring. The AudioSensor also supplies the
central station operator with verification audio to help identify the
cause of an alarm loop violation.
Advantor Glass Break - The Advantor Glass Break is a versatile,
dual-function, audio verification sensor and glass break detector. It
contains an adjustable glass breakage detector and verification audio
capability in a single unit.
Audio Detection - Audio detection describes the proven method of
using AudioSensors in combination with SmartAudio Modules for
volumetric detection of intrusions. An unrecognized sound triggers an
AUDIO Activation and alerts the central monitoring central station.
Audio Verification - Audio verification is live audio sent to the
central monitoring station console when a violation occurs. The
monitoring operator uses this audio to assist in identifying the cause
of an alarm loop violation.
Base Module - The primary control unit for Advantage plus systems.
The Base Module directs and controls all other optional modules and
devices and provides communication with the SONICS central
monitoring console.
The Base Module provides sixteen programmable alarm loops, up to
eight separate zones, a Wiegand card reader input, and four balanced
audio inputs for verification audio. The Base Module's RS-485
communication port can interface and control the following:
• any combination of 16 LCD plus and LED plus keypads
• eight alarm loop Expansion Modules
• any combination of up to eight SmartAudio Modules or
ListenIn Modules
• one Wireless Module*
• seven Access Modules
*NOTE: This module has not been investigated and installation is
not permitted in UL Listed systems.
Downloaded from - http://www.guardianalarms.net
Installation Instructions for:
___________________________________________________________
Copyright © 1997 by Advantor Corporation. All rights reserved.
No part of this document may be reproduced or distributed in any form or by any means, or stored
in a database or retrieval system, without the prior written permission of Advantor Corporation.
(P/N: AVR PLUS)
P/N 09820450
Revision A
Expansion Module - The Expansion Module is a Base Module add-
on unit that provides the system with an additional sixteen supervised,
programmable alarm loops and four additional auxiliary outputs. The
Advantage plus Base Module can interface and control up to eight
Expansion Modules.
LCD plus Keypad - The LCD plus keypad is a fifteen button wall-
mounted keypad in its own enclosure. The keypad contains a four
line, twenty character per line Liquid Crystal Display (LCD) that
displays the Advantage plus' status in plain English.
ListenIn Module- The ListenIn is an optional unit that when added
to the Advantage plus Base Module gives the system the ability to
support sixteen additional audio verification sensors (AudioSensors or
GlassBreaks). The Advantage plus Base Module can interface and
control any combination of up to eight ListenIn Modules and/or
SmartAudio Modules.
SmartAudio Module - An optional add-on module that gives the
Advantage plus system audio detection capability. The SmartAudio
Module supplies eight audio detection circuits and connections for up
to sixteen audio sensors (Advantor Audio Sensors). The Advantage
plus Base Module can interface and control any combination of up to
eight SmartAudio Modules and/or ListenIn Modules.
TelPlus - The TelPlus is an optional add-on unit that, when added to
the Advantage plus Base Module, provides a second telephone line
interface with the SONICS central station monitoring console.
You can configure the TelPlus for either a second dial telephone
interface, or as the primary dedicated telephone line and use the
Base Module's telephone interface for a backup dial communication.
NOTE:
You can configure the Base Module's telephone line
connection for either dial line or dedicated line connec-
tion (but not both). Only use the TelPlus to provide a
second telephone line interface.
Wireless Module - An optional add-on module that interfaces the
Base Module with up to 63 spread spectrum (long range) wireless
transmitters with individual detector identification. The Base Module
can control one Wireless Module.
NOTE:
This module has not been investigated and installation is
not permitted in UL Listed systems.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANTAGE PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Advantor ADVANTAGE PLUS

  • Page 1 (P/N: AVR PLUS) P/N 09820450 Revision A See the Advantage plus Service Manual (P/N 09820460) for operational theory and service procedures. See the SONICS Database Management Manual (P/N 09820426) for options programming procedures. ___________________________________________________________ Copyright © 1997 by Advantor Corporation. All rights reserved.
  • Page 2 Each of the listed add on devices and modules can be located up to disarm as a group with associated auxiliary outputs and audio 2,000* feet from the Base Module giving the Advantage plus the verification or audio detection AudioSensors.
  • Page 3 • Program the Bell Ring Length option for 15 minutes or longer. The Advantage plus Base Module must be connected to a • The current drawn by the equipment and devices powered from compatible Listed sounding device suitable for the applica-...
  • Page 4 Normal Standby current cannot exceed 0.58 Amps s u l e l u To properly calculate the Advantage plus system’s battery t s i e l u capacity you MUST evaluate the Normal Standby and Alarm l e r...
  • Page 5: System Grounding

    To Dial ALL WIRING IS COMPLETE. Telephone Line SYSTEM GROUNDING Optional Ditek NOTE: All Advantage plus modules isolate earth ground Data Protector from signal ground. This is done to meet UL (P/N 08060085) requirements, and also allows all the interconnect...
  • Page 6: Battery Wiring

    ON A BASE MODULE 12 VOLT LINE CAN BLOW THE Table 2 lists audible and visual devices that are compatible with TRANSFORMER. ALWAYS USE BATTERY POWER Advantage plus. TO PERFORM THE PRE-INSTALLATION TEST. Table 2. Compatible Audible/Visual Devices If the Base Module cannot pass this test, replace it and test the new...
  • Page 7 Do not connect a ground wire to a +AS terminal, which is +12VDC. NOTE: When installing SmartAudio or ListenIn Modules in the Advantage plus system we strongly recommend that you DAT1 & DAT2 (J4 Pins 1 through 4) not connect AudioSensors to the Base Module audio Base Module J4 pins 1 through 4 are the RS-485 communication port inputs.
  • Page 8 Table 3 lists smoke detectors and other devices compatible with To provide the required alarm circuit supervision, you must install Advantage plus Fire systems. When installing 4-wire smoke one of the supplied 1KEOL end-of-line resistors in series with alarm- detectors you must also install Power Supervision Unit(s). Recom-...
  • Page 9 Advantage plus Installation Diagram NOTE : All UL Fire and Burglary installations Dial Telephone Line must use the fused RJ31X jack included Connection in the ULB and ULF Installation Kits. 11/10/97 To House Recommended Fire Initiating Telephone WARNING! Loop Connection...
  • Page 10 Fire - Strobe + (Optional) Figure 7. Advantage plus Installation Diagram (Sheet 2 of 2) C. A combination of A and B works nicely. Door Unlocked from Connect the card reader to Base Module J5 pins 16 through 19 using...
  • Page 11: Setting System Time

    Only LCD plus keypad #1 operates before the system is previous options) or equipment with failed options: downloaded. Place an Advantage plus system with no options into the Test Mode Base Module Calls Monitoring Station Method by powering it up with the TEST/OPER switch (S1) in the TEST 1.
  • Page 12 Pressing the Loops or Call With the phone line LOOP STATUS REPLAY SAM AUDIO buttons displays the status disconnected, pressing the Loop # 16 shorted TEST of system alarm loops Store button forces the tested (open, shorted, normal). panel to store the next 5 Prior Quit Replay...
  • Page 13: Communication Loss

    If the system contains SmartAu- returns you to the Call Figure 23. Download Mode Screen dio Modules, use the Advantor Calibrator set to AUDSEN and Mode screen (Figure 22). TRIP to trigger audio activations. Use this screen to enter the...
  • Page 14: Fcc Regulations

    ADVANTOR CORPORATION HARDWARE LIMITED WARRANTY STATEMENT Advantor Corporation warrants each new product of its manufacture, to be free from defects in material and workmanship. It will repair or replace defective parts for a period of 24 months from the date of manufacture, providing the equipment has not been subjected to abnormal conditions such as misuse, abuse, misapplication, alteration, lightning damage or damage by an Act of God.