Verilux EasyFlex Deluxe Natural Spectrum VF02 Instructions Manual

Floor lamp
Hide thumbs Also See for EasyFlex Deluxe Natural Spectrum VF02:

Advertisement

Quick Links

Model: VF02
VF02_MAN_Rev14.indd 1
12/29/11 4:24 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EasyFlex Deluxe Natural Spectrum VF02 and is the answer not in the manual?

Questions and answers

Summary of Contents for Verilux EasyFlex Deluxe Natural Spectrum VF02

  • Page 1 Model: VF02 VF02_MAN_Rev14.indd 1 12/29/11 4:24 PM...
  • Page 2 Many other healthy lighting products are available through our catalog and online. Visit us on the web at www.verilux.com to request a free catalog and learn more about all our quality Verilux products, or call us toll-free at 1-800-454-4408. Have a bright day! Nicholas Harmon President, Verilux, Inc.
  • Page 3: Important Safeguards

    READ ALL INSTRUCTIONS BEFORE USING Important Safeguards DANGER: • Do not operate this lamp near a water source to avoid electrocution. WARNING: • Do NOT dismantle. • Do not use with power supply voltage other than 120 VAC. • Do not operate lamp in close proximity to flammable or combustible vapors, such as aerosol spray products, or where oxygen is being administered. • Do not cut or shorten the power cord. • The bulb in this product contains a trace amount of mercury, a chemical known to the state of California to cause birth defects or other reproductive harm.
  • Page 4: Mesures De Sécurité Importantes

    VEUILLEZ LIRE L’INTÉGRALITÉ DES INSTRUCTIONS AVANT TOUTE UTILISATION Mesures de sécurité importantes DANGER : • N’utilisez pas cet appareil à proximité d’une arrivée d’eau pour éviter tout risque d’électrocution. AVERTISSEMENT : • Ne pas démonter. • Avant de brancher la lampe, vérifier que la tension de la prise murale ne dépasse pas 120 volts. • Ne pas faire fonctionner la lampe à proximité de vapeurs inflammables ou combustibles, tels que les produits aérosol, ou lorsque l’oxygène est administré. • Ne pas couper ou raccourcir le cordon d’alimentation. • Ce produit contient du mercure dans son ampoule suivre les reglements locaux pour la mise au rebut de l’ampoule. MISE EN GARDE : • Pour usage intérieur seulement. • Ne pas utiliser avec des gradateurs de lumière, des minuteries, des détecteurs de mouvement ou des rallonges.
  • Page 5: Getting Started

    Getting Started Main Parts & Controls A. Ergonomic Handle B. Lamp Head C. High/Off/Low Switch D. Gooseneck E. Shaft F. Ergonomic Height Adjustment Lever G. Lamp Base H. Power Cord I. Tray J. Bulb K. Parabolic Light Diffuser Close-up of Lamp Head CAUTION: CAUTION: DO NOT LIFT THE LAMP BY THE GOOSENECK. THE LAMP SHOULD BE LIFTED BY THE SHAFT.
  • Page 6 Getting Started — continued Please Read Instructions Carefully Before Using the EasyFlex ® 1. Unpack lamp carefully, removing all packaging material, and confirm you have all parts shown in the diagram. For your convenience, the bulb has been inserted into the socket. 2. Remove all pieces from box being careful with the wiring that runs through the base and shafts. 3.
  • Page 7 Assembly Instructions 1. Attach the lamp head gooseneck to the shaft until the screw holes line up as shown in Fig. 1. Use care when tucking the wire into the shaft. Insert the screw using the tightening tool and turn clockwise to tighten. Close-up of screw hole in the lamp head Fig.
  • Page 8 Assembly Instructions — continued 3. Set the lamp base on the floor and insert the lamp shaft over the base support unit until the screw holes line up as shown in Fig. 3. Insert the screw using the tightening tool and turn clockwise to tighten. Close-up of screw hole in the lamp base Fig.
  • Page 9: Bulb Replacement

    Bulb Replacement Removal 1. Unplug the lamp from the power source and allow bulb to cool. 2. To access the bulb, remove light diffuser by depressing the tab and lifting it out (Fig. 7). 3. Firmly hold the bulb base (B) and pull bulb (C) from the socket (A) in an outward motion (Fig. 8). Fig.
  • Page 10: Troubleshooting

    Troubleshooting Before requesting service on your Verilux lamp, please read the ® following: • Make sure all power connectors, cords and plugs are inserted fully and securely. • Be sure the bulb is securely seated into the socket (see page 9). • Make sure there is power to the wall outlet or try another outlet. Be sure the bulb is securely seated into the socket, repeat the bulb installation process. ALWAYS UNPLUG LAMP BEFORE CAUTION: PERFORMING BULB REPLACEMENT OR INSTALLATION.
  • Page 11: Care And Cleaning

    Care & Cleaning Your lamp is made from high quality materials that will last for many years with minimum care. You may want to periodically clean the lamp, using a mild non-abrasive cleaner and soft cloth. When cleaning, make sure you have turned off and unplugged the unit, and allowed sufficient time for the unit to cool.
  • Page 12: One Year Limited Warranty

    Many questions may be answered by visiting www.verilux.com, or you may call our Customer Service Department at 800-786-6850 during normal business hours. This limited warranty is provided by: Verilux, Inc., 340 Mad River Park, Waitsfield, VT 05673 Verilux warrants this product to be free from defects in material and workmanship for a period of one year from the date of the original retail purchase from Verilux or an authorized Verilux distributor. Proof of purchase is required for all warranty claims. During the limited warranty period, Verilux, Inc.

Table of Contents