Summary of Contents for REnex Technology ZcoRE3-2400 series

  • Page 1 REnex Technology Ltd ZcoRE3-2400 (ZcoRE3-2400/ZcoRE3(20)-2400) OEM Serial Wireless Transceiver Module User Manual Version 1.0 May, 2007...
  • Page 2 This manual is produced for users of the ZcoRE3-2400 OEM wireless transceiver module from REnex Technology Limited. It covers the operating principles and capabilities of the ZcoRE3-2400 module. It is recommended that you read this document before using the ZcoRE3-2400 module in order to operate it correctly and optimize its performance.
  • Page 3 This manual contains information of proprietary interest to REnex Technology Limited. It has been supplied in confidence to purchasers and other authorized users of the ZcoRE3-2400 module, and by accepting this material, the recipient agrees that no part of the document shall be reproduced or transmitted in any form or by any means, without prior written consent of REnex Technology Limited.
  • Page 4 ZcoRE3-2400_User_Manual_V1.0 Document Version History: Version Release Date Comment V1.0 Feb 28,2007 Initial Release V1.1 May 18 2007 Updating for Approval...
  • Page 5: Table Of Contents

    ZcoRE3-2400_User_Manual_V1.0 Table of Content Introduction..........................1 Technical Parameters ........................2 Module Interface ........................3 1.27 mm Pin Header Interface..................3 RF Interface........................6 RMCI interface......................7 Wakeup..........................8 Power Supply ..........................8 Module Configuration.......................8 RAEMESH Module Command Interface (RMCI)..............11 6.1.1 Serial port setting .................... 11 6.1.2 Package format....................11 6.1.3 Quick review of RMCI..................12 Mechanical Drawing .......................17...
  • Page 6 ZcoRE3-2400_User_Manual_V1.0 Terms: Coordinator: A FFD used for gateway. Only one coordinator per network. FFD: Full Function Device. Sensor node with routing ability. FFD requires line power all time. RFD: Reduce Function Device. A Sleeping node can only talk to a FFD or Coordinator. Can not relay the message.
  • Page 7: Introduction

    ZcoRE3-2400_User_Manual_V1.0 Introduction The ZcoRE3-2400 serial OEM transceiver module is a small size, high performance wireless module, which is designed to provide a cost efficient solution for reliable data transmission and low power consumption. It is ideal for low data rate wireless applications, including sensor monitoring, building automation, security systems and any other application requiring low power consumption.
  • Page 8: Technical Parameters

    ZcoRE3-2400_User_Manual_V1.0 Technical Parameters Table 2.1 Technical Parameters of ZcoRE3-2400/ZcoRE3(20)-2400 Radio Characteristics RF Frequency Band 2.4 ~ 2.4835GHz Number of Channels 16 channels Channel Spacing 5 MHz RF Data Rate 250 kbps Modulation OQPSK Duplex 1 (0 dBm) ~ 60 mW (18 dBm) Maximum E.R.P.
  • Page 9: Module Interface

    ZcoRE3-2400_User_Manual_V1.0 Module Interface The module interface includes the power input (3.3 V), power output (3.3 V), configuration button signal, serial ports (CMOS 3.3 V), A/D, I C, test signal, JTAG and digital I/O, etc. These are integrated on a dual row, 20 pins per row, 1.27 mm pitch connector (J1). Refer to Table 3.1 for a detailed pin definition.
  • Page 10 ZcoRE3-2400_User_Manual_V1.0 The pin definition of the header interface is shown on Table 3.1; the input and output description is based on module side. The main serial port is port 1 which includes TxD1 (pin 5) and RxD1 (pin 7). It will be set as the default port in the factory. There are three UART ports which can be used on the module.
  • Page 11 ZcoRE3-2400_User_Manual_V1.0 Table 3.1: Pin Definition of J1 Function IN/OUT Description Remark COMM Ground COMM Ground Reset signal input External reset, active low COMM Ground TxD1 UART1, transmit data Default serial port TxD0 UART0, transmit data RxD1 UART1, receive data Default serial port RxD0 UART0, receive data GPIO0...
  • Page 12: Rf Interface

    ZcoRE3-2400_User_Manual_V1.0 RF Interface Different RF interfaces are provided on the ZcoRE3-2400 module. For the ZcoRE3-2400 module, only a chip antenna can be soldered on when the modem ship out. Refer to diagram below for detail information of chip antenna. For the ZcoRE3(20)-2400 module, only the external antenna is available. P1 (refer to mechanical drawing) is designed on PCB board for the reversed SMA antenna connection via a special RF cable.
  • Page 13: Rmci Interface

    Polarization Vertical V.S.W.R Less than 2.0 Peak gain 1.5 dBi Mechanical Item Specifications Remarks Element RG-316 cable Sleeve Urethane Black Base Nylon 66 Black Connector SMA male Ni plate 168 ± 3 mm Antenna total length RMCI interface The module is pre-loaded with the EmberZnet bootloader (version:1005), which supports both over-the-air bootloading and serial bootloading of firmware update.
  • Page 14: Wakeup

    ZcoRE3-2400_User_Manual_V1.0 Wakeup If the radio is set to RFD mode, the Wakeup pin Pin19 is used to make the radio asleep and wakeup. A constant high on this pin will make the radio go to the sleep mode and a low level signal on this pin will wake-up the radio.
  • Page 15 When the sensor node sends data to gateway, the gateway will receive the data plus the last four digits of sensor node ID in the {}. When the gateway sends data to sensor node, the sensor node radio will only receive data in the {}. For RAEWATCH_RCS The data in the {} will be untouched by either gateway or sensor node.
  • Page 16 ZcoRE3-2400_User_Manual_V1.0 Base on correct setting and connection, you will see following display on your screen when power is applied. Coordinator: EVENT: emberInit passed INIT: sink app 000D6F0000002DF8 chan:0x1A, pwr:FF, panID:0x30FF EVENT: stack Status now EMBER_NETWORK_UP EVENT: setting multicast binding, status is 0x00 FFD: EVENT: emberInit passed FFD SENSOR APP: joined to network...
  • Page 17: Raemesh Module Command Interface (Rmci)

    ZcoRE3-2400_User_Manual_V1.0 RAEMESH Module Command Interface (RMCI) 6.1.1 Serial port setting Between RDTE and RRCM: 38400 bps, 8N1 Between SDTE and SRCM: 19200 bps, 8N1 6.1.2 Package format Packet format as listed below: Length Command Code Command Data Byte The minimum length for one packet is 4 bytes long. The Length is 0x20 based. E.g. the total length of a packet without command data is 4, the Length byte is 0x20 + 4 = 0x24.
  • Page 18: Quick Review Of Rmci

    ZcoRE3-2400_User_Manual_V1.0 Check the Network Status of the RFD before sending the data at the first time. Command: 5B24205D. It is recommend 1s interval between two data packets for RFD. Check [] for sending acknowledge in Unicast mode. There is no ACK for multicast mode. For RFD, if there is no network, the RCM will automatically wake up every 1 minute to search for a new network.
  • Page 19 Table 5.2.1: Detailed information of RMCI package CMD Data Response Response CMD Command Name Code (bytes) CMD Code Data (Bytes) Description NETWORK_STATUS 0x20 None 0x21 STATUS(1) Return the radio’s network status 0x00: NO NETWORK Use on: 0x01: JOINING NETWORK Coordinator 0x02: JOINED NETWORK 0x03: JOINED_NETWORK_NO_PARENT 0x04: LEAVING NETWORK...
  • Page 20 Table 5.2.2: Detailed information of RMCI package CMD Data Response Response CMD Command Name Code (bytes) CMD Code Data (Bytes) Description FFD_ENABLE 0x32 None 0x33 None Set radio to FFD. Always on and has router function. Use on: Coordinator/RFD CHG_RRCM_CHAN 0x34 Channel 0x35...
  • Page 21 Table 5.2.3: Detailed information of RMCI package CMD Data Response Response CMD Command Name Code (bytes) CMD Code Data (Bytes) Description PRINT_TOKEN 0x4E None 0x4F Print radio’s Token information in ASCII. Use on: Coordinator/FFD/RFD For PC debug JION_FORM_NETWORK 0x50 None 0x51 None Coordinator:...
  • Page 22 Table 5.2.4: Detailed information of RMCI package CMD Data Response Response CMD Command Name Code (bytes) CMD Code Data (Bytes) Description GET_PARENT_ID 0x68 None 0x69 Parent radio Get the parent ID for RFD ID(8) Return: 5B 2C 69 00 0D 6F 00 00 00 2E CB 5D Use on: if no parent, return 5B 2C 69 00 00 00 00 00 00 00 00 5D...
  • Page 23: Mechanical Drawing

    ZcoRE3-2400_User_Manual_V1.0 Mechanical Drawing Top View Units: mm Note: 1: E1 is for the chip antenna and available only in ZcoRE3-2400. The length of the chip antenna is less than 7.3mm 2: P1 is the MMCX connector for SMA antenna (connect via an MMCX-SMA RF cable) and available only in ZcoRE3(20)-2400.
  • Page 24: Bottom (Top Perspective)

    ZcoRE3-2400_User_Manual_V1.0 Bottom (top perspective) Units: mil Note: J1 is the application and power supply interface (1.27mm pin header) which can be used for board-to-board connection. Pay attention to the direction of socket. There are two holes on board revered for modem fixing.
  • Page 25: Order Information

    Worldwide REmesh-2400* 18 dBm Standalone Europe 18 dBm Standalone REmesh-868* 18 dBm Standalone REmesh-915* *Available in 2007 Product Ordering Information for the ZcoRE3-2400 series: Products Part Number of REnex ZcoRE3 -2400 R-001-0003-410 ZcoRE3(20) -2400 R-001-0003-400 Reference: Ember: www.ember.com Atmel: www.atmel.com FCC: www.gcc.gov...