Shyam RF/DBR Series Operation & Installation Manual

Dual band six sub-band repeaters for in-door applications
Hide thumbs Also See for RF/DBR Series:

Advertisement

Quick Links

O
O
Six Sub-Band Repeaters for In-Door Applications
5920 0060 200
The information contained herein is proprietary to
Unauthorized access, copy and replication are prohibited. This document must not
be copied in whole or part by any means or it shall not be disclosed or divulged to
any third Party without the prior written consent of
All Rights Reserved
P
E
R
A
T
I
O
N
&
I
N
P
E
R
A
T
I
O
N
&
I
N
D
B
6
M
R
2
0
D
B
6
M
R
2
0
FCC ID:S3CDB6MR20 IC: 5751A-DB6MR20
Proprietary Information
Shyam Telecom Limited
RF / DBR Series
S
T
A
L
L
A
T
I
O
N
M
S
T
A
L
L
A
T
I
O
N
M
( Dual Band)
(
Shyam Telecom
Shyam Telecom
Next Generation
Signal Enhancement
A
N
U
A
L
A
N
U
A
L
December 2008
Limited.
Limited.
Page
1/43

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RF/DBR Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Shyam RF/DBR Series

  • Page 1 Unauthorized access, copy and replication are prohibited. This document must not be copied in whole or part by any means or it shall not be disclosed or divulged to any third Party without the prior written consent of Shyam Telecom Limited. Page All Rights Reserved Shyam Telecom Limited 1/43...
  • Page 2: Table Of Contents

    7.6. Contents of Delivery ................27 8. Installation ....................28 8.1. Preparation Sheet-Pre Installation............28 8.2. Engineering Consideration ..............29 8.3. Installation Tools..................31 8.4. Installation Procedure ................32 8.5. Gain Settings ..................33 8.6. Commissioning ..................34 8.7. Checklist – Post Installation..............35 Page All Rights Reserved Shyam Telecom Limited 2/43...
  • Page 3 Next Generation Signal Enhancement 8.8. Dos & Don’t Dos ..................36 8.9. Display Details of DB6MR20 ..............37 9. System Maintenance................... 38 9.1. General....................38 9.2. Preventative Maintenance ..............38 9.3. In-Building Coverage Problems .............38 Page All Rights Reserved Shyam Telecom Limited 3/43...
  • Page 4: Document History

    Next Generation Signal Enhancement 1. Document History Document Document Date Compiled Approved by Revision Number Name 5920 0060 200 DB6MR20 December Inderjit Ramvir Singh Repeater 2008 Revision Revised Section Date Intentionally Left Blank Page All Rights Reserved Shyam Telecom Limited 4/43...
  • Page 5: Disclaimer

    Shyam Telecom Limited assumes no liability for the customer's failure to comply with these precautions.
  • Page 6: Electrostatic Sensitivity

    RF input connector, and through the AC connector pins. When unpacking and otherwise handling the Repeater, follow ESD precautionary procedures including the use of grounded wrist straps, grounded workbench surfaces, and grounded floor mats. Page All Rights Reserved Shyam Telecom Limited 6/43...
  • Page 7: Introduction

    The purpose of this document is to describe the electrical and mechanical specifications, operation and maintenance of the DB6MR20 Repeater. 4.2. Scope This document is the product description of the Shyam DB6MR20 Repeater for indoor applications. 4.3. Definitions Automatic Gain Control...
  • Page 8: References

    • Area to be provided with coverage. • Indoor/outdoor coverage. • Availability of BTSs in the vicinity. • Antenna isolation to be achieved. Page All Rights Reserved Shyam Telecom Limited 8/43...
  • Page 9: Functional Description Of Db6Mr20 Repeater

    Management System (RMS). It enables status monitoring, remote configuration & speedy maintenance. • The system is modular in nature & can be customized to meet requirement of user in terms of number of sub bands with the desired Page All Rights Reserved Shyam Telecom Limited 9/43...
  • Page 10 The choice of suitable metal as the case material gives a lightweight design with good heat conduction. It is not waterproof and therefore, should be installed at indoor locations only. Ceiling Antenna Page All Rights Reserved Shyam Telecom Limited 10/43...
  • Page 11: Typical In-Building Coverage

    Indoor coverage varies greatly due to the nature of various building construction techniques materials. Approximations signal level/coverage can be determined with the following assumptions: • 10dBi to12dBi-donor antenna. Max. 9dBi indoor omni/directional antenna. Page All Rights Reserved Shyam Telecom Limited 11/43...
  • Page 12 • Isolation between the donor and server antennas should be 15 dB more than the gain of the repeater. DB6R20 Repeate Figure 2: Application of DB6MR20 in a multi-storey building Page All Rights Reserved Shyam Telecom Limited 12/43...
  • Page 13 Next Generation Signal Enhancement Ceiling Antenna DB6MR20 Figure 3: Typical Indoor Coverage Application in Train Page All Rights Reserved Shyam Telecom Limited 13/43...
  • Page 14: To Get Started-Basic Software Control Of The System

    There are two types of users viz. ADMINISTRATOR and SUPERVISOR. If user logged in as an ADMINISTRATOR, all the operation through the CMC can be carried out. The password by default is “SHYAM”. SUPERVISOR is allowed to perform monitoring of the status & alarms but no change in configuration is permitted.
  • Page 15 Figure 4: Log-in Repeater II) Configuration Configuration means setting different repeater parameters for proper operation. Configuration of Shyam repeaters can be performed locally with a laptop / PC connected to the repeater by means of local USB serial interface cable.
  • Page 16 Next Generation Signal Enhancement Figure 5: Repeater ID/Location Settings Figure 6: Frequency Settings in sub bands Page All Rights Reserved Shyam Telecom Limited 16/43...
  • Page 17 Through this setting, the attenuation is inserted in both the bands in UL & DL paths as per the requirement of RF power. It is carried out when the system is set in manual mode. In automatic mode whatever attenuation is inserted, is displayed. Page All Rights Reserved Shyam Telecom Limited 17/43...
  • Page 18 Next Generation Signal Enhancement Figure 8: PA ON/OFF Settings Figure 9: Threshold Settings Page All Rights Reserved Shyam Telecom Limited 18/43...
  • Page 19 Displays the temperature of PAs in DL & UL in both the bands System Temperature Displays the temperature of the system Alarms Displays if there is any alarm viz. critical, major or minor. Details can be viewed by clicking at “DETAIL ALARM”. Page All Rights Reserved Shyam Telecom Limited 19/43...
  • Page 20 Monitoring interval is 3 seconds i.e. after every 3 seconds data on the monitoring window will be refreshed. A red indication is for Alarm present. A green indication is for No alarm. Page All Rights Reserved Shyam Telecom Limited 20/43...
  • Page 21 In this type of connection, User communicates from/to remote location with the repeater using wireless Modem / Cell phone. To connect: • Click the “COMM.” on the command bar to display the COMMUNICATION window. Page All Rights Reserved Shyam Telecom Limited 21/43...
  • Page 22 It is through a Password, which can be set/reset. Click the Password on the command bar to display Password Setting window where administrator can change password. Page All Rights Reserved Shyam Telecom Limited 22/43...
  • Page 23 Next Generation Signal Enhancement Figure 13: Communication Setting Figure 14: Password Settings Page All Rights Reserved Shyam Telecom Limited 23/43...
  • Page 24: Block Diagram Description

    Refer to Figure 15 c. Low Noise Amplifier (LNA) This module is provided after each quad-plexer in the repeater before the converter. The LNA provides compensation for the losses suffered by the Page All Rights Reserved Shyam Telecom Limited 24/43...
  • Page 25 Based on the coverage area, a set of select omni/directional antenna(s) having proper gains ( less than 9dBi) with connecters may be installed at pre-planned spots. Page All Rights Reserved Shyam Telecom Limited 25/43...
  • Page 26: Db6Mr20 Repeater Specifications

    10 dB 7.2. Electrical Specification Power Requirement Parameters Specified/Limits Input AC Voltage Range 100-240 V, 47/63 Hz Power Consumption Approx. 80 watts (Shall vary depending on the number of sub bands equipped) Page All Rights Reserved Shyam Telecom Limited 26/43...
  • Page 27: External Electrical Interface

    Repeater unit DB6MR20 – Model as per requirement PC interface cable for USB port Power cable with 3 pin plug Operation & Installation manual CD containing the application software Wireless Modem (Optional) Page All Rights Reserved Shyam Telecom Limited 27/43...
  • Page 28: Installation

    ERP at server antenna Desired RF Power in UL Proposed gain settings in UL path Proposed Attenuator to be inserted in UL path 3. Proposed site Address: --------------------------- 4. User’s Address & other particulars: --------------------------------- Page All Rights Reserved Shyam Telecom Limited 28/43...
  • Page 29: Engineering Consideration

    • The antennas should have proper frequency band of operation. • Adequate separation is to be ensured from the power lines to avoid damage to the equipment and humans. Page All Rights Reserved Shyam Telecom Limited 29/43...
  • Page 30 However, when desired isolation cannot be met due to insufficient separation, external shielding can help; for example, mounting the antennas on either side of a rooftop penthouse or Page All Rights Reserved Shyam Telecom Limited 30/43...
  • Page 31: Installation Tools

    8.3. Installation Tools You will need the following basic tools for installation: a. Standard wrenches/screwdrivers/cable stripper/cable cutter/pliers set for installing the DB6MR20 Unit and antennas. (Refer to the manufacturer’s recommendations for installing the antennas). Page All Rights Reserved Shyam Telecom Limited 31/43...
  • Page 32: Installation Procedure

    2. Fix the supplied connectors to the RF cable and verify the following: • The center conductor to outer shield of RF coaxial cable indicates “Open Circuit” condition. • Check for any short circuit between center conductor and outer shield. Page All Rights Reserved Shyam Telecom Limited 32/43...
  • Page 33: Gain Settings

    Local USB serial interface mode (GUI based) b. Remote through (optional) wireless modem. Reverse Gain Setting For reverse gain setting, 31dB variable attenuator is inserted in accordance with the attenuation inserted in the DL. Page All Rights Reserved Shyam Telecom Limited 33/43...
  • Page 34: Commissioning

    Measure & monitor signal level at various points within and around the perimeter of the coverage area with a mobile handset loaded with NET engineering software and the SIM card of cellular operator. Page All Rights Reserved Shyam Telecom Limited 34/43...
  • Page 35: Checklist - Post Installation

    Repeater switched ON Any error (alarms) observed Gain set Power level in DL Attenuation in DL Power level in UL Attenuation in UL Observation on CMC software & GUI Page All Rights Reserved Shyam Telecom Limited 35/43...
  • Page 36: Dos & Don't Dos

    RF power in the DL RF power in the UL Antenna Isolation Gain settings in DL & UL 13. Feedback regarding performance of the system may be sent to Shyam Telecom by the user. Page All Rights Reserved Shyam Telecom Limited...
  • Page 37: Display Details Of Db6Mr20

    Alarm LED will Glow when the system goes to the shut down mode due to input power going/out put power going high (beyond ALC) in DL path. • Downlink RSSI is continuously monitored and level is displayed through 8 LED’s. Page All Rights Reserved Shyam Telecom Limited 37/43...
  • Page 38: System Maintenance

    Soldering or local repair of the modules should be avoided. Faulty module/unit should be replaced with genuine spares from Shyam Telecom Limited only. However, the power supply of the faulty unit should be isolated from AC mains and DC power before any module is replaced.
  • Page 39 Technical support team. The unit serial number must be available to establish a return authorization. If replacing any part, Shyam authorized service dealer should replace it and no soldering/ repairing of PCBs should be carried out in the field for reliable service thereafter.
  • Page 40 TYPICAL PRODUCT APPLICATION Celling Antenna DB6R20 Figure 20: Indoor Application of DB6MR20 in a room Page All Rights Reserved Shyam Telecom Limited 40/43...
  • Page 41 Next Generation Signal Enhancement DB-6R-20 Ceiling Antenna Figure 21: Indoor Application DBR6R20 in a Corridor Page All Rights Reserved Shyam Telecom Limited 41/43...
  • Page 42 (2) this device must accept any interference received, including interference that may cause undesired operation. IC Statement: Trade Name: SHYAM Dual Band Inddor Repeater Model No.: DB6MR20 IC: 5751A-DB6MR20 This device complies with RSS-131, RSS-102 of the IC Rules.
  • Page 43 Next Generation Signal Enhancement For Technical Support, please contact at any of the following addresses: For Americas Shyam Telecom Inc. 6, KILMER ROAD, SUIT D, EDISON, New Jersy-08817 (USA) For Europe Shyam Telecom GmbH. Frohsinnstrasse 16, 63739 Aschaffenburg, Germany Tel: + 49-6021-45901-0 Fax: + 49-6021-45901-29 For Asia Pacific Shyam Telecom Ltd.