Page 1
VESTEL WATER HEATER SERVICE MANUAL VESTEL WATER HEATER SERVICE MANUAL COVERS ALL BATH STOVES IN THE FIELD MANUFACTURED IN VESTEL FACTORIES...
Page 2
VESTEL WATER HEATER SERVICE MANUAL VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 1...
Page 3
2-7 Limit thermostat. Hot water heaters are equipped with "maximum temperature" thermostat. This safety device deactivates the main thermostat and heating coils in case of a failure. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 2...
Page 4
E2 error code is displayed. After the voltage is restored to desired level E2 error will disappear and the water heater will commence its normal operation. “This safety system is only available in electronically controlled models.” VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 3...
Page 8
SOIL GREY BLUE C : KLEMENS LT : LIMIT THERMOSTAT T : THERMOSTAT R: HEATING COIL L : SIGNAL LAMP F : FLANGE 20850064 – ELECTRICAL DIAGRAM ANALOG TYPE VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 7...
(3) Lower dome (4) Drum flange (5) Cold water inlet pipe (6) Input diffuser. Prevents turbulence and provides cold water inlet from the bottom of the tank. (7) Drum VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 8...
Contact one of the probes to one of the ends and other probe to flange gasket. If the value is shown, it is defective, if not it is intact. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 9...
Page 11
Thermocouple must be installed in the steel pipe such a way that it is secured to the bottom part. Signal lamp is lit red while water is heated to temperature that thermostat is set. Signal lamp lights up green when water reaches the desired temperature. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 10...
Page 12
The protective lexan film tag in front of the display must be replaced when it is deformed. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 11...
Page 13
(2) Hot water ready indicator lamp (1) On-Off ButTon (4) Higher Temperature Setting Button (3) Heating Coil Activation (5) Lower Temperature Setting Button Lamp (7) Bacteria Prevention Lamp Electronic thermostat. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 12...
4- When limit thermostat cuts the circuit, water temperature in the drum is decreased to 60°C for reactivation by pressing the red button. 5- Minimum 30 minutes must pass for limit thermostat to be reactivated. 6- Limit thermostat has a lifespan of 10 trippings. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 13...
Page 15
Move the level of your measurement device to Ω (ohm) position and measure the resistance. 1- Limit thermostat is constantly active if it is not tripped. 2- If limit thermostat is tripped, red button comes out and breaks the circuit. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 14...
Page 16
Drain latch safety valve. 2- Protection 2: It is activated when drum pressure exceeds 8 bar. It discharges the water inside through drain hose to reduce drum pressure. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 15...
Page 17
Thus, it is the magnesium that becomes a solution. At this point, magnesium leaves anode and combines with oxygen atoms. Corrosion ends, in other words, while thermostat stays the same magnesium anode is abraded. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 16...
Tank is always filled with pressurized water. When desired temperature is reached, the control thermostat turns off the electrical resistance. When hot water is used, cold water intake starts to tank through cold water intake pipe. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 17...
Water connection hose sleeves have flexible gaskets. Sleeves must be sufficiently tightened to prevent water leakage. If extremely tightened, sleeves and gaskets may be damaged. If hose length is not sufficient, different sizes of hoses recommended by Vestel Service Center must be used. ...
Page 20
7. Remove the screws that holds the flange (that heating coil is connected). 8. Remove the flange. 9. Clean the scale manually or using a tool (depending on appliance type) carefully. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 19...
Page 21
10. The magnesium anode stick must be replaced every 2 years. 11. Flange gasket must be replaced every time heating coil is removed from the drum. FLANGE GASKET FLANGE VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 20...
Remove sensor and electronic card and measure resistance values. Is Replace Sensor. there open or short circuit? Replace electronic card. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 21...
Page 23
Heating coil is excessively scaled or sensor slot is very close to the source of heat. Replace the scaled heating coil or move the sensor slot away from heating coil. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 22...
Page 24
Cool the water in the drum Is limit thermostat tripped? and reinstall limit thermostat. Check temperature Check the thermostat. Is output heating coil and provided to heating coil? replace if defective. Replace thermostat VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 23...
Page 25
Remove sensor from control card Replace and perform measurements. Is there Sensor. Replace limit any deviation in sensor values? thermostat. Thermostat is faulty, replace it. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 24...
Page 26
Check heating coil resistance values. Are there any broken Replace heating coil. cables or short circuit? Hot water pipe is not mounted or fell inside the appliance. Fix and start the appliance. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 25...
* Replace the thermostat. enabled/disabled * Heating coil may be covered * Clean heating coil. frequently. with scale. * Check the supply voltage. * There may be faulty power input. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 26...
Page 28
NOTE: Temperature control is electronic in certain models of water heaters. For this reason, thermostat used for heat control is digital. It detects heat through a sensor. VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department) Page 27...
Need help?
Do you have a question about the TRV 50 and is the answer not in the manual?
Questions and answers