SATIE
mains
replacement
The following work should only be carried
out by a qualified technician in accordance
to highest electrical safety standards. Risk of
electric shock.
Replacing the fuse
The fuse must be replaced by a 0.63AT type
(5x20mm). Never attempt to short the fuse
holder. Normally the fuse should never blow – if
it has, it is a sign of a serious fault condition.
Further investigation is needed.
Mains voltage
Altering the mains input voltage range from
115V to 230V or vice versa is done by changing
the fuses. You will need 1x 0,63AT for 230 V
operation and 2x 0,63AT for 115V operation.
Never
attempt
configuration or a short circuit condition will
occur.
voltage
selection
to
apply
18
/
any
other
fuse
!
fuse

Advertisement