Technical Data - Whirlpool ACCESS AWM 9100-B Service Manual

Table of Contents

Advertisement

01.09.2006 / Page 2
Doc. No: 4812 722 25971

Technical data

Dimensions
Height
Width
Depth
Weight
Without noise protection 111
With noise protection
Main connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Wash spin
Ramp spin
Speed spinning max.
Capacity of dry laundry
Sanitary
Whitest Whites
Heavy Duty
Normal/Casual
Express Wash
Delicate
Silk/Wool/Ultra Handwash 2.0
Pressostat for washing-machine
Level1
Switching point
Reset
Level2
Switching point
Reset
Overflow
Switching point
Water column drum
(measured inside of the drum, rear position)
Level1
Foamlevel by water run in not measurable
Level2
Switching point
Overflow
Switching point
AWM 9100-B
8570 083 72001
96.5
cm
68.6
cm
78.5
cm
kg
112
kg
230
V
50 ± 3
Hz
2.3
kW
10
A
87
l
35/40
rpm
100
rpm
1000
rpm
9
kg
9
kg
9
kg
3.5
kg
2.0
kg
2.5
kg
kg
55 ± 5
mmWc
35 ± 5
mmWc
80 ± 5
mmWc
60 ± 5
mmWc
280 ± 20
mmWc
69 - 78
mm
250 - 292
mm
Whirlpool Europe
Customer Service
Nominal current
Contacts:
11 - 14
21 - 22
21 - 24
21 - 26
Contactsystem:
11 - 12/14
21 - 22/24
21 - 26
Damping system
Door lock
Nominal current:
contacts
4 - 5
6 - 7
8 - 9
Coil 1 - 2 and 2 - 3:
Nominal voltage
Frequency
Resistance 1 - 2 (lock)
Resistance 2 - 3 (unlock)
Locking time
Unlocking time
(max.6 cyles)
Heating element
Kind of heating
Nominal voltage
Nominal power
Heat conductor
resistance R25
Resistance NTC:
0 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
95 ˚C
S E R V I C E
~3 mA
24 V DC
~3 mA
24 V DC
~3 mA
24 V DC
~3 mA
24 V DC
jump contacts
jump contacts
slow action contacts
no
16 A
230 V
16 A
230 V
0.1 A
230 V
230
V
45 - 65
Hz
Ω ± 10%
133
Ω ± 10%
140
40 ± 10
ms
1
s
Tubular heating element
with NTC- Sensor
230
V
2050
W
22 - 28
35.9
kΩ
9.8
kΩ
6.6
kΩ
4.6
kΩ
3.2
kΩ
2.3
kΩ
1.1
kΩ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents