Pole Barn Construction Guide 
 
How to use this guide: This guide can be used for buildings which are a maximum of 2,400 
square foot.  (max width 40' and max length of 60')  Larger buildings must be engineered. 
Complete the Residential Detached Accessory Building application, provide a plot plan and a full 
set of building plans.  Stamped engineered truss plans are required to be on site for inspections.
Building plans: The following pages are approved methods for pole barn construction in 
Laramie County without the need for additional engineering.  Pole barns that do not meet the 
minimum standards of these guidelines will be required to be designed by a Wyoming 
licensed engineer. 
Building Codes:
Be advised that the governing building codes for Laramie County are the 2015 
 
International codes and the 2014 National Electrical Code.  
Fees:
 There is a $100 base fee for the structure.  Additional fees are calculated for bonus rooms using 
the square footage of the rooms.   
 
Bonus rooms are defined (but not limited to) bathrooms, utility rooms, non‐dwelling spaces, offices, 
libraries, enclosed storage spaces.
 
Description 
Accessory only 
Bonus Room 
 
 
 
 
 
 
 
 
X:\BUILDING DIVISION\BUILDING APPLICATIONS_FORMS\APPLICATIONS AND FORMS‐2017‐APPROVED\P1_POLE 
BARN CONSTRUCTION GUIDE.docx 
3966 Archer Pkwy  Cheyenne, WY 82009 
Building department phone #: (307) 633‐4512 
 
Price per 
Square 
 
square 
Footage 
foot 
NA 
NA 
 
$ 43.00 
 
 
 
revised 04/06/2017
Valuation 
NA 
Total Fees Owed:  $ 
 
4:23 pm by rm
 
 
Fees 
*see fee schedule 
$ 100.00 

Advertisement

loading

Summary of Contents for Laramie County Pole Barn

  • Page 1 Laramie County Planning & Development Office  3966 Archer Pkwy  Cheyenne, WY 82009  Building department phone #: (307) 633‐4512  www.laramiecounty.com     building@laramiecounty.com       Pole Barn Construction Guide    How to use this guide: This guide can be used for buildings which are a maximum of 2,400  square foot.  (max width 40’ and max length of 60’)  Larger buildings must be engineered.  Complete the Residential Detached Accessory Building application, provide a plot plan and a full  set of building plans.  Stamped engineered truss plans are required to be on site for inspections.     Building plans: The following pages are approved methods for pole barn construction in  Laramie County without the need for additional engineering.  Pole barns that do not meet the  minimum standards of these guidelines will be required to be designed by a Wyoming  licensed engineer.  Building Codes: Be advised that the governing building codes for Laramie County are the 2015    International codes and the 2014 National Electrical Code.   Fees:  There is a $100 base fee for the structure.  Additional fees are calculated for bonus rooms using  the square footage of the rooms.      Bonus rooms are defined (but not limited to) bathrooms, utility rooms, non‐dwelling spaces, offices,    libraries, enclosed storage spaces.   Price per  Square  Fees  Description    square  Valuation  Footage  *see fee schedule  foot  Accessory only  NA ...
  • Page 2 Laramie County Planning & Development    POLE BARN CONSTRUCTION  PURLINS MAX 24” OC (ON CENTER)  TRUSSES BY WYOMING  LICENSED ENGINEER  SEE PAGE #4  BRACING PER  TRUSS DETAIL  MIN 29 GA STEEL  6” X 6” OR (3) 2” X 6”  MAX 8’ OC TREATED  BELOW GROUND  WALL GIRT MIN  2”X6” MAX 30” OC  MAX WALL HEIGHT 14’  TREATED GRADE BOARD  MIN 2”x 6”  CAISSON MIN 18”W X 48” DEPTH UP TO 32’ WIDTH OF  BUILDING 24”W X 48” DEPTH FOR 32’‐40’ WIDTH OF BUILDING.   CONCRETE OR COMPACTED EARTH        MIN 6” CONCRETE 1  2                                                                                                                        ...
  • Page 3: Floor Plan

    Laramie County Planning & Development     FLOOR PLAN       POST 8' O.C. MAX SPACING  HEADERS SHALL BE IN ACCORDANCE WITH  IRC TABLE R602.7 (1)  MAX  LENGTH  SEE PAGE 2 FOR FOOTER SIZE    IDENTIFY ALL DOORS       MAX WIDTH 40'   3       X:\BUILDING DIVISION\BUILDING APPLICATIONS_FORMS\APPLICATIONS AND FORMS‐2017‐APPROVED\P3_FLOORPLAN POLE BARN.docx                                         3/15/2017 4:29 PM...
  • Page 4 Laramie County Planning & Development   Approved Truss Connection      Truss between bearing posts Truss Supports       Stub post structurally  fastened to truss extends to    bottom of supports +/‐  Structural  fasteners each    support to stub    Minimum 2” x 12”                Bolts 4   ...
  • Page 5 PURLIN DETAILS  Laramie County Planning & Development   PURLIN SIZE AND SPACING PER TRUSS SPACING    FOR 4’ O.C. TRUSSES- 2”X4” PURLINS FLAT @ 24” O.C. FASTEN WITH 3-16d OR 2-20d NAILS FOR 6’ O.C. TRUSSES- 2”X4” PURLINS ON EDGE @ 24” O.C 2‐16d EACH SIDE OF LAP  FOR 8’ O.C. TRUSSES- 2”X6” ON HANGERS @ 24” O.C. 5 ...
  • Page 6 PURLIN DETAILS  FOR 8’ ON CENTER TRUSSES 2”X6” PURLINS ON LISTED HANGERS 6  3/15/2017 2:53:01 PM     ...
  • Page 7 Laramie County Planning & Development      CORNER BRACING                 END FRAME BOTTOM CHORD  END FRAME TOP CHORD                                                     ...
  • Page 8 Laramie County Planning & Development Office  3966 Archer Pkwy  Cheyenne, WY 82009  Building department phone #: (307) 633‐4512  www.laramiecounty.com     building@laramiecounty.com           Pole Barn /Accessory Building Restrictions    It is important for home owners to understand that pole barns are generally NOT designed for  residential family dwellings.  Problems occur when homeowners attempt to build or remodel  a pole barn for a residential occupancy.  Issues with the foundation system, fire separation,  plumbing and roof design may occur.  These issues can require costly alterations to bring the  structure into compliance with the current building codes adopted by Laramie County.    In addition, there may be Land Use regulations that prohibit a second residence or a residence  created for a rental unit.  If the pole barn is built to be occupied as a residential dwelling it  shall meet the requirements of the 2015 International Residential Code, shall be permitted  with a residential permit and meet the requirements of the Laramie County Land Use  Regulations.  If you have any questions regarding permitting and the use of the pole barn structure please  ask!  I have read and understand that this application for an accessory structure does not meet the  requirements of a family dwelling and will not be inhabited as a family dwelling.     __________________________________________________      _________________  Land Owner Signature              Date  __________________________________________________        Printed Name ...