To delete a pipe, use the arrow keys to highlight the relevant pipe to remove and press 6.
To delete all pipe data press 0.
To use a manual velocity the user has calculated, press 4 and type in the new velocity value,
this will automatically update the default value for the current correlation only.
To enter and store extra user defined velocity's and diameters, press 2 Materials, then press
1 Edit materials, then press 1 Edit table, then press 3 Add entry. To restore to factory set
values see Test and Service menu.