Start-Frequency Switch Settings - Andrew MR803D User Manual

Minirepeaters
Table of Contents

Advertisement

10.

Start-Frequency Switch Settings

As described in chapter 4 Functional Description, the
miniRepeaters utilise a high rejection filter to allow
only the desired frequency band to be repeated. The
miniRepeaters are available in different bandwidths
with field adjustable start frequencies to support the
desired frequency band of the user.
Two rotary switches, located on the side of the
miniRepeater, are provided for setting the start
frequency (SF) of the high rejection filter. The SF of
the high rejection filter may be adjusted in either 200
or 250 kHz steps, dependent upon the miniRepeater
model.
miniRepeater Model: MR803D
Start Frequency
miniRepeater Model: MR853D
Start Frequency
M0041AMB.doc
Start Frequency
Setting 1
Setting 2
0
0
0
1
0
2
...
...
F
0
1
0
1
1
...
...
F
1
...
...
F
0
F
1
...
...
F
F
Start-frequency setting MR803D
Start Frequency
Setting 1
Setting 2
0
0
0
1
0
2
...
...
F
0
1
0
1
1
...
...
F
1
...
...
F
0
F
1
...
...
F
F
Start-frequency setting MR853D
Following are tables that show the filter band-pass
start frequencies corresponding to the switch settings.
The following section will show tables of standard
user settings.
SF setting 1
(positions 0 - F)
Rotary switches for start-frequency setting
Frequency Step Size: 200 kHz
Start Frequency
Start Frequency
UL (MHz)
DL (MHz)
796.00
796.20
796.40
...
799.00
799.20
799.40
...
802.20
...
844.00
844.20
...
847.00
Frequency Step Size: 200 kHz
Start Frequency
Start Frequency
UL (MHz)
DL (MHz)
814.00
814.20
814.40
...
817.00
817.20
817.40
...
820.20
...
862.00
862.20
...
865.00
SF setting 2
(positions 0 - F)
841.00
841.20
841.40
...
844.00
844.20
844.40
...
847.20
...
889.00
889.20
...
892.00
859.00
859.20
859.40
...
862.00
862.20
862.40
...
865.20
...
907.00
907.20
...
910.00
ID No 7164468