Dok PPC-1000 Technical Description And Operations Manual

Wireless 1 gigabit bridge

Advertisement

Quick Links

РРС-1000
Technical Description and Operation Manual
St. Petersburg, Russia, 2006
Rev. 1.0
Feb, 2006
PPC-1000
Rev.1.0
© DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
DOK Ltd
(Mm-wave Division of ELVA-1 ltd)
2 Voroshilova str,
193318 St. Petersburg, Russia
T: +7-812-326-5924,
F: +7-812-326-1060
Wireless 1 Gigabit Bridge
1 of 29
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PPC-1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dok PPC-1000

  • Page 1 T: +7-812-326-5924, F: +7-812-326-1060 РРС-1000 Wireless 1 Gigabit Bridge Technical Description and Operation Manual St. Petersburg, Russia, 2006 Rev. 1.0 Feb, 2006 1 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 2: Table Of Contents

    Installation ......................10 Connections......................16 Station alignment ....................20 Installing and using SNMP software................ 24 Maintenance and Troubleshooting ................28 Specifications ..................... 29 2 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 3 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 3 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 4 Elva-1 Millimeter Wave Division unless expressly reduced to writing and approved by an officer of Elva-1 Millimeter Wave Division. 4 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 5 For installations in the USA, refer to Articles 810830 of the National Electrical Code, ANSI/NFPA #70, for information with respect to proper grounding and applicable lightning protection for DC cables. 5 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 6 This product should be operated only from the type of power source indicated on the unit or in manual. 6 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 7: Introduction

    ELVA-1 Millimeter Wave Division 2 Voroshilova str Ohta Business Centre St.Petersburg, 193318 Russia Tel: +7 (812) 326-5924 Fax: +7 (812) 326-1060 Email: support@elva-1.com 7 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 8: Product Description

    As both Radios operates in a full duplex mode, they should be connected to an equipment, operating in a full duplex mode. 8 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 9: Site Planning

    1,2 m 5 km 3,2 m 2,5 m 2,3 m 1,9 m 10 km 4,5 m 3,5 m 3,1 m 2,7 m 9 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 10: Installation

    The paper boxes with accessories are fastened to a bottom of the shipping box. Remove their shipping straps and take out the boxes with accessories. 10 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 11 Wrench 8 mm & 17 mm * Media converter (optional, to convert STM-1 to Fast Ethernet) *) The item is supplied on demand only 11 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 12 Replace the rest 5 shipping bolts with bolts, nuts, washers and tightening washers (set #14). The exact number of the bolts used for shipping purpose may differ. 12 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 13 Click Network Connection – Properties - IP protocol – Properties on your stand-alone computer to set up a temporal IP address for this computer from the same subnet as radio default IP address. 13 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 14 Run PPC Monitor application your computer. Then click START and GET buttons. • You have to get a reply from the transceiver, similar to the following one. 14 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 15 Use the hose clip #8 to prevent the Radio from shipping down when run the alignment of the radio. 15 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 16: Connections

    Normally it is convenient to place it near the network termination equipment and the main. Fix Indoor cross-box. • Install the stationary DC power cable from the Outdoor Cross-box to Indoor one. 16 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 17 The grounding cable at radio side has to be connected to earth connector, marked with the earth symbol (bolt M5, see photo on page 12). 17 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 18 This product is not designed to withstand direct thunderbolt. It should be operated only under protection of external lightning rod. 4.11 Power connection indoor • Connect stationary DC cable to Indoor cross-box with terminal block 18 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 19 Ethernet connection. With the link power switched on, and installed SNMP software you can use link SNMP administration from one of the office PC. 19 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 20: Station Alignment

    • Using the bolt “Vertical” (top), direct the Radio to the other end of the link in vertical plane 20 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 21 Passport are provided for mainlobe. You need to know exact distance between two radios of the link. Use GPS navigator or range-finder to calculate exact distance of the link path. 21 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 22 Try to stop the antenna horizontally at center of the virtual arc between two AGC voltage minimums, then slowly scan the antenna vertically to find mainlobe. 22 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 23 In such a case you advised to change the location of the radios. 23 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 24: Installing And Using Snmp Software

    4. Click to Search button in main window of NE SDK Manager (most left button at toolbar). The NE SDK Manager will find MOXA switch, which is build-in to transceiver. 24 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 25 8. Click again to Search button in main window of NE SDK Manager. When MOXA switch will found, sure that IP-address just entered. 9. Repeat steps changing IP-address second transceiver. 10. Close NE SDK Manager. 25 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 26 30 Seconds only. After 30 sec the transceiver will return to internal automatic microprocessor control. This is to prevent damage of the equipment. 26 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 27 SET button – to make active changes which made for power on/off, heater and fan on/off. START – starts PPC Monitor application. STOP - stops PPC Monitor application 27 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 28: Maintenance And Troubleshooting

    Passport for actual distance. If it is not so, discover and remove the cause. Possible causes: • Precipitation along the signal propagation line. Wait until the good weather and repeat the measurements. 28 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.
  • Page 29: Specifications

    Diameter, cm Gain, dB Beam angle, deg Diameter/Band 28.3 34.0 35.7 34.6 39.7 41.7 38.5 42.4 45.0 42.9 45.4 44.9 47.5 29 of 29 PPC-1000 Rev.1.0 User Manual © DOK Ltd (Mm-wave Division of ELVA-1 ltd), 2005-2006. All rights reserved.