Download Print this page

Optex OA-AXIS T Original Instructions page 2

Advertisement

ADJUSTMENTS
1
Area depth angle adjustment
Depth angle
adjustment screw
When adjusting the 1st row close to the door,
see 3-11 Installation mode for the easier adjustment.
Make sure that the detection area does not overlap with the door/header, and there is no highly reflecting
NOTE
object near the detection area otherwise ghosting/signal saturation may occur.
1-1.Independent adjustment
1st to 3rd rows
Shallow
Deep
Depth angle adjustment screw
for the 1st to 3rd rows
Red
Use the area adjustment tool (A) as shown above to
change the area depth angle for the 1st to 3rd rows.
4th and 5th rows
Shallow
Deep
Depth angle adjustment screw
for the 4th and 5th rows
Blue
Use the area adjustment tool (B) as shown above to
change the area depth angle for the 4th and 5th rows.
1-2.Simultaneous adjustment
For the simultaneous adjustment of the 1st to 5th rows, use the adjustment tool (C).
REFERENCE
Area depth adjustment with INFRARED FINDER (Separately available)
1. Turn the depth angle adjustment screw to the right (Deep) to place the detection area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (High) and place it on the floor as shown below.
Detection area
Detection area
3. Turn the depth angle adjustment screw to the left (Shallow) until the emitting area is placed at the position where
INFRARED FINDER is in the low detection status (Slow Red Blinking).
2
Area width adjustment
1st to 3rd rows
4th and 5th rows
1 2 3
10 11 12
1 2 3
Eliminated
Eliminated
Eliminated
Eliminated
Eliminated
Eliminated
Narrow
Wide
Width adjustment
Width adjustment
screws (Left)
screws (Right)
NOTE
When adjusting the width adjustment screws, make sure to turn until it clicks otherwise the proper operation may not
be obtained.
cannot be eliminated separately, neither can
1 2 3
3
Dipswitch settings
After changing the dipswitch settings, make sure to push the function
switch for 2 seconds.
3-1.Setting the sensitivity
Refer to the chart below for the suitable sensitivity to your installation environment.
2.0 (6'7")
Low reflection
Middle
Middle reflection
Low
High reflection
Low
Special attention to the setting is required when the door is used often by the elderly or children.
NOTE
Please adjust the sensitivity and the presence detection timer according to your risk assessment.
3-2.Setting the presence timer
The 1st and 2nd rows have the presence detection function.
NOTE
To enable the presence detection, do not enter the detection area for 10 seconds after setting the timer.
3-3.Setting the frequency
When using more than two sensors close to each other, set the different
frequency for each sensor by dipswitches 5 and 6.
3-4.Setting the row adjustment
Set the depth rows with dipswitches 7 and 8.
When "2rows" are selected, the activation output
NOTE
is disabled.
3-5.Setting the immunity
Set dipswitch 9 to "ON" when the sensor operates by itself (Ghosting).
NOTE
When dipswitch 9 is set to "ON", the actual detection area may become smaller.
3-6.Setting the self monitoring
When the door remains open and the LED indicator shows fast or slow green
blinking, please refer to the TROUBLESHOOTING.
If the door still remains open, set dipswitch 10 to "Disable".
NOTE
To comply with EN 16005, dipswitch 10 must be set to "Enable".
Area adjustment tool
A
C
Deep
Shallow
2.0 (6'7")
3.0 (9'10")
2.0
1.0
2.0
0
-1.0
(6'7")
(3'3")
(6'7")
(3'3")
Deep
Shallow
2.0 (6'7")
3.0 (9'10")
3.0
2.0
1.0
0
3.0
2.0
(9'10")
(6'7")
(3'3")
(9'10")
(6'7")
INFRARED FINDER
Front view
0
10 11 12
Eliminated
Eliminated
Narrow
2.0
(6'7")
Wide
1 2 3
4 5 6
7 8 9
3.0
(9'10")
2.0
1.0
0
(6'7")
(3'3")
.
10 11 12
push 2 seconds
Low
Middle
1
2
1
2
Mounting height [ m (feet,inch) ]
2.2 (7'3")
2.5 (8'2")
3.0 (9'10")
For example
-Carpet
Middle
High
S-High
-Dark color floor
Middle
Middle
S-High
-Concrete
-Tile
Low
Middle
High
-Marble
30sec.
60sec.
180sec.
3
4
3
4
Setting1
Setting2
Setting3
5
6
5
6
5rows
4rows
3rows
7
8
7
8
7
8
Enable
3-7.Setting the Safety output (to door controller)
Dipswitch11 is for the Safety output (to door controller).
B
3-8.Setting the Safety input (from door controller)
Dipswitch12 is for the Safety input (from door controller).
NOTE
The delay time between Safety input and Safety output is 10msec..
3-9.Settings the direction recognition
When Dipswitch13 is set to "Uni", uni-directional function is activated.
This function enables the door to close faster if a person walks away from the door.
[m(feet,inch)]
Uni-directional function is disabled in case the detection at 1st and/or 2nd row continues
NOTE
for more than 5sec..
3-10.Setting the Activation output
Dipswitch14 is for the Activation output to door controller.
1.0
0
-1.0
(3'3")
(3'3")
3-11.Installation mode
[m(feet,inch)]
Set dipswitch 16 to "ON" to adjust the 1st row.
During the Installation mode only the 1st row remains active and the operation indicator shows yellow.
After setting the row set dipswitch 16 "OFF".
CHECKING
0
1.0
(3'3")
Check the operation in the operation mode according to the chart below.
Entry
Status
Operation indicator
14
N.O.
Activation
output
14
N.C.
11
High
Safety
output
11
Low
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
[m(feet,inch)]
WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator blinks Green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
NOTE
10 11 12
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
1.0
2.0
(3'3")
(6'7")
TROUBLESHOOTING
Door operation Operation
indicator
None
Door does not
open when a
person enters
Unstable
the detection
area.
Proper
Door opens
Unstable
when no one
is in the
detection area.
High
S-High
(Ghosting)
1
2
1
2
Proper
Door remains
Proper
open
Yellow
Fast
Green
600sec.
Blinking
3
4
3
4
Slow
Green
Blinking
Setting4
Red &
5
6
5
6
Green
Blinking
2rows
Proper
Slow
operation
Green
Blinking
7
8
* After changing the dipswitch settings, make sure to push the function switch for 2 seconds.
OFF
ON
Manufacturer
OPTEX Co.,LTD.
9
9
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77 579 8700
FAX.: +81(0)77 579 7030
WEBSITE: www.optex.co.jp/as/eng/index.html
Disable
North and South American Subsidiary
OPTEX Technologies Inc.
10
10
Corporate Headquarters
18730 S. Wilmington Ave. Suite 100 Rancho Dominguez,
CA 90220 U.S.A.
TOLL-FREE: 800 877 6656
WEBSITE: www.optextechnologies.com
Outside of
Entry into
Entry into
Power OFF
detection
3rd to 5th row
area
Motion
-
Stand-by
detection active
Green
Orange
None
OFF
ON
OFF
OFF
Possible cause
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure.
Check the wires and connector.
Wrong detection area positioning.
Check ADJUSTMENTS 1, 2, 3. (*)
Sensitivity is too low.
Set the sensitivity higher.(*)
Short presence timer.
Set the presence timer longer. (*)
Dirty detection window.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Wrong wiring or connection failure.
Check the wires and connector.
Remove the objects.
Objects that move or
emit light in the detection area.
The detection area overlaps
Check ADJUSTMENTS 3-3.(*)
with that of another sensor.
Waterdrops on the detection window.
Use the rain-cover. (Separately available)
Or wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Or install in a place keeping the waterdrops off.
The detection area overlaps with
Adjust the detection area to "Deep" (Outside).
the door/header.
Sensitivity is too high.
Set the sensitivity lower.(*)
Others
Set dipswitch 9 to "ON".(*)
Check ADJUSTMENTS 3-7, 3-8, 3-10.(*)
Wrong setting of dipswitches .
Check ADJUSTMENTS 3-1, 3-2.(*)
Sudden change in the detection area.
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again.)
Wrong wiring or connection failure.
Check the wires and connector.
Installation mode is set to " ON ".
Set dipswitch 16 to " OFF ".(*)
Sensitivity is too low.
Set the sensitivity higher.(*)
Dirty detection window.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Contact your installer or service engineer.
Sensor failure.
Signal saturation. (1st or 2nd row)
Remove highly reflecting objects from the
detection area. Or lower the sensitivity.(*)
Or change the area depth angle for 1st to 3rd rows.
The detection area overlaps with
Adjust the detection area to "Deep" (Outside).
the door/header.
Setting error.
After changing the dipswitch settings, make
sure to push the function switch for 2 seconds.
Signal saturation. (3rd, 4th or 5th row)
Remove highly reflecting objects from the
detection area. Or lower the sensitivity.(*)
Or change the area depth angle.
European Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague,The Netherlands
TEL.: +31(0)70-419-4100
E-MAIL: info@optex.eu
East Coast Office
8510 McAlpines Park Drive, Suite 108 Charlotte,
NC 28211 U.S.A.
FAX.: +1 310 214 8655
TOLL-FREE: 800 877 6656
WEBSITE: www.optextechnologies.com
High
Low
11
11
High
Low
12
12
Bi
Uni
13
13
N.O.
N.C.
14
14
OFF
ON
16
16
Outside of
Entry into
detection
2nd row
1st row
area
Motion / Presence
Stand-by
detection active
Red
Blinking Red
Green
OFF
ON
ON
OFF
Possible countermeasures
FAX.: +31(0)70-317-7321
WEBSITE: www.optex.eu
FAX.: +1 704 365 0818

Advertisement

loading

This manual is also suitable for:

I-twoOp-08cwOp-08cblI-one