ACURT2 and ACURT4
Information Packet
Description:
Device Name:
Polling Address:
Serial Port Number:
Dial-Up Phone Number:
IP Address:
IP Router Address:
This information packet is for reference only.
See the TOPAZ Hardware Installation Guide
for complete instructions.
DO NOT REMOVE FROM CABINET
UTC Fire & Security
9 Farm Springs Road,
Farmington, CT 06034-4065
(888) 437-3287
www.UTCFireandSecurity.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Topaz ACURT2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Interlogix Topaz ACURT2

  • Page 1 ACURT2 and ACURT4 Information Packet Description: Device Name: Polling Address: Serial Port Number: Dial-Up Phone Number: IP Address: IP Router Address: This information packet is for reference only. See the TOPAZ Hardware Installation Guide for complete instructions. UTC Fire & Security 9 Farm Springs Road, Farmington, CT 06034-4065 (888) 437-3287...
  • Page 2 Copyright Copyright © 2010, UTC Fire & Security Inc. All rights reserved. This document may not be copied or otherwise reproduced, in whole or in part, except as specifically permitted under US and international copyright law, without the prior written consent from UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034- 4065.
  • Page 3: Table Of Contents

    Table of contents This packet includes information about: DIP Switch SW1 Settings ......1 DIP Switch SW2 Settings .
  • Page 4 ACURT2 and ACURT4 Information Packet...
  • Page 5: Dip Switch Sw1 Settings

    DIP Switch SW1 Settings Note: See page 11 for switch location. Switch ON Position = Terminated – OFF Position = Not Terminated Host TX Line Terminated Host RX Line Terminated Expansion Module Port TX Line Terminated Expansion Module Port RX Line Terminated Current Switch Setting SW 1 Circle the current setting...
  • Page 6: Dip Switch Sw2 Settings

    ACURT2 and ACURT4 Information Packet DIP Switch SW2 Settings Note: See page 11 for switch location. Switch Switch Setting Function Host Communication Baud Rate OFF OFF 19200 OFF OFF 38400 57600 1200 115200 through 2400 4800 9600 Host Encryption disabled Host Encryption enabled Dial-up Host Communications Dedicated Host Communications...
  • Page 7 Current Switch Setting SW 2 Circle the current settings...
  • Page 8: Dip Switch Sw3 Settings

    ACURT2 and ACURT4 Information Packet DIP Switch SW3 Settings Note: See page 11 for switch location Switch Description OFF = LAN Disabled ON = LAN Enabled OFF = Do Not Allow LAN IP Parameters to be Updated ON = Allow LAN IP Parameters to be Updated OFF = Do Not Use LAN default IP Parameters ON = Set IP Address To 192.168.0.132 OFF = Triple DES Disabled...
  • Page 9: Rotary Switch Sw4 Setting

    Rotary Switch SW4 Setting Note: See page 11 for switch location Function - Sets the ACURT polling (rotary) address Current Setting 0 - F Address 0-F DIP Switch SW5 Settings Note: See page 11 for switch location ON POSITION = terminated – No Input Device Off Position = Not Terminated –...
  • Page 10: Dip Switch Sw6 (Acurt4 Only)

    ACURT2 and ACURT4 Information Packet DIP Switch SW6 (ACURT4 Only) Note: See page 11 for switch location ON POSITION = terminated – No Input Device Current Off Position = Not Terminated – Zone In Use Setting Terminates Zone Input Reader 2 Zone 0 Terminates Zone Input Reader 2 Zone 1 Terminates Zone Input Reader 2 Zone 2 Terminates Zone Input Reader 3 Zone 0...
  • Page 11: Clearing The Memory On The Acurt

    Clearing the Memory on the ACURT CAUTION: Before clearing memory you should record all switch settings. This will assist you in setting them back to their original locations after clearing the memory. Note: See page 11 for switch and LED locations. To clear memory: 1.
  • Page 12: Power-Up Self-Test

    ACURT2 and ACURT4 Information Packet Power-Up Self-Test The Controller should always be tested after installing any module. The power-up self-test indicators are LEDs on the printed circuit board assembly. At power up, all of the LEDs will light, then all turn off. The LEDs will light as follows (at power- up): all ON at hardware reset, then all OFF.
  • Page 13: On-Line Led Definitions

    Note: See page 11 for LED locations Description ON if zone monitor voltage reference is ever out of range LED 4 (indicates board or power supply failure). On-Line LED Definitions LAN Status LEDs Description ON When transmitting. ON When receiving. ON When collision occurs.
  • Page 14: Battery Replacement

    ACURT2 and ACURT4 Information Packet Battery Replacement Replace RAM back-up battery every five years using 3 AAA Nickel-Cadmium. Replace the clock/calendar battery every five years with 1 CR2023 Lithium or the equivalent. Replace the UPS batteries as needed. Always replace both batteries: 12 volt, 1.2 amp hour (Ah) Gel Cell.
  • Page 15: Acurt2 And Acurt4 Component Layout

    ACURT2 and ACURT4 Component Layout Attach to Grounding Stud in Panel LAN Status Optional dial-up LEDs Modem Card LAN Port TB10 POWER SWITCH LINK EXP. MODULE COMMUNICATION TRANSMIT DATA LED +5VDC LEDS +3.3VDC HOST PORT LED1 TB11 RECEIVE DATA LED +12VDC LED3 AC ON...
  • Page 16: Terminal Block Tb1 Connection Information

    ACURT2 and ACURT4 Information Packet...
  • Page 18: Terminal Block Tb3 Connection

    ACURT2 and ACURT4 Information Packet...
  • Page 19: Terminal Block Tb5 Connection

    ACURT2 and ACURT4 Information Packet...
  • Page 20: Terminal Block Tb6 Connection

    ACURT2 and ACURT4 Information Packet...
  • Page 22: Terminal Block Tb9 Connection (Acurt4 Only)

    ACURT2 and ACURT4 Information Packet...
  • Page 24: Terminal Block Tb12 Connection (Acurt4 Only)

    ACURT2 and ACURT4 Information Packet...
  • Page 27: Terminal Block Tb16 Connection (Acurt4 Only)

    ACURT2 and ACURT4 Information Packet...
  • Page 28: Terminal Block Tb18 Connection (Acurt4 Only)

    ACURT2 and ACURT4 Information Packet...