  • Page 1 Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach        OMS Bayonet Mount P‐Valve   Instruction Manual          oms pvalve manual 110216.docxoms pvalve manual 110216.docx   ...
  • Page 2 Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach    Dear Customer,    Your OMS® Team appreciates your confidence in choosing our product.  Our products are designed to offer comfort, reliability and safety and are manufactured with  only high‐quality materials and the utmost care. In addition, each product is thoroughly tested  before delivery to ensure reliability.  At OMS® we are continuously working to improve our products. For this reason, we would  appreciate it if you would pass on any thoughts or comments on the use or design of our  products to Support@OMSDive.com.   The OMS® Bayonet Mount P‐Valve incorporates three unique innovative benefits.   • The bayonet mount system allows the valve to be quickly and easily removed from the  suit for routine maintenance. The bayonet mount allows the valve to be removed and a  blanking plug installed for dives when a P‐Valve is not needed.   • The valve’s balanced design uses a traditional Protective Vacuum Breaker Valve backed  with a semipermeable membrane, an OMS® original feature. The membrane prevents  debris from entering the valve and fluid from entering the suit in the event of a valve  failure.    • The Fast Lock Cap opens and closes with a simple quick 1/3 turn when a quick response  is needed, versus the common two or more full turns.  Before installation and use of this product, please take the time to read this manual in detail.  With the contents of this manual, you are equipped for proper operation and long term  performance.  You can contact us with any questions about our products at any time       Your OMS® Team      oms pvalve manual 110216.docxoms pvalve manual 110216.docx   ...
  • Page 3 Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach    Bayonet Valve Overview (What is in the box)                         oms pvalve manual 110216.docxoms pvalve manual 110216.docx   ...
  • Page 4 Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach    Installation  Materials Needed  The installation of the P‐Valve must be carried out only by  authorized persons.   You will need the following:     • OMS® P‐valve  • Aquaseal® (Aquaseal® Cotol‐240™ Combo pack  contains Aquaseal®, Cotol‐240™ and application  brush) (Aquasure® is a replacement in Europe)  • OMS® P‐Valve body wrenches  • Marker: Wax, Crayon, Chalk  • Punch 38 mm or 1‐1/2 inch  • Punch block or piece of wood   • Hammer  • 60 to 80 grit sandpaper    Installation Process  Disassemble P‐Valve (from the out of box assembly)  1. Rotate the Fast Lock Cap fully clockwise to the fully  closed position and you will feel a solid stop, then  rotate cap 1/3 of a turn counter‐clockwise, till you  feel a stop. Then press down and rotate the cap an  additional 1/3 counter‐clockwise. The cap should  become loose. Pull the cap up and it will come free.  Only a little force is needed to do this.  2. Remove P‐Valve body from the bayonet mount ring ...
  • Page 5 41199 Mönchengladbach    thigh to mount the valve on, either the left or right. For men it is simply how do you wear your  pants “dressed left” or “dressed right”? For women it is more a question of personal preference  and divewear features. This preference dictates the preferred thigh for valve placement and  once this decision has been made there are two additional factors to consider. The first is the  position of the valve on the thigh and the second is the planned routing of the connection tube  between the valve and the external catheter.  Is the routing straight up, so that the connection  hose passes though the base of the undergarment’s zipper or if routed at an angle so that it can  pass though the P‐Valve connection tube ports built into the undergarments. Sometimes these  ports are up by the base and/or the side of the zipper and other times they are located on the  thigh of the undergarment.     To optimize these decisions, it is best to start by dressing out in your undergarment and any  other items to be worn under the undergarment so that the routing of the connection tube can  be established. It is critical that the connecting tube does not make any sharp turns which could  kink, which could restrict or block flow.   After the routing placement and connecting hose angle has been determined, don the drysuit  and mark the P‐Valve position with chalk or a wax marking pen. An additional factor to consider  is that a “good" position is always away from and not on a seam.  Cut the hole in the drysuit  The marked hole can be cut with scissors or punched with a punch and hammer. A sharp punch  produces the best results. The ideal hole diameter should be 1‐1/2 inches (38 mm). When  punching the hole, it is very important to have a stable punching block on the underside of the  layer being punched through to ensure that the underlying suit material is not punched through  or damaged in the process.  Some suit materials are quite resilient, therefore it is recommended to hit the punch with  several blows, without lifting the punch between strikes. Lifting the punch can lead to more  than one hole and partially punched holes developing.   Installation of Bayonet Base  Items needed: Bayonet Base, Retaining Ring and Tools  Turn the drysuit inside out before proceeding with the installation of the valve base. You want  the suit laying out in such a manner that you have access to both sides of the punched hole.  This needs to be done so that a proper connection hose angle can be controlled.  Before finally mounting the bayonet system, the drysuit and the parts to be assembled should  be cleaned and free of grease for better applying Aquaseal®. Cotol 240™ is ideal for cleaning  these surfaces. The sealing surfaces of the bayonet base can be lightly sanded to improve the  bond. Remember to clean after sanding.  oms pvalve manual 110216.docxoms pvalve manual 110216.docx   ...
  • Page 6 Thread the locking ring in place on the  outside of the suit and thread on till hand  tight, all the while taking care that the two   parallel surfaces on the bayonet lockin g  ring stay aligned. Once finger tight, use the supplied wrenches to snug the rings in place, always  paying attention to the alignment of the bayonet locking ring. Wipe up any excess adhesive  that  extrudes from under the bayonet locking ring. It is a good idea to wait a few hours before  proceeding to the next step. If the adhesives have not been allowed to cure the alignment of  the bayonet locking ring could shift.  Installing the P‐Valve Body and Fast Lock Cap  The Fast Lock Cap should be removed if you have replaced it. From the  inside of the suit, align the two straight parallel sides with valve body  with the parallel straight sides of the bayonet mount. Press in place  then rotate clockwise to 90 degrees. Once you start rotating, release  the downward tension and valve body will lock in place once it reaches  90 degrees. Once locked in place the valve body will not rotate unless  you apply downward pressure.  Turn the suit right side out to install the Fast Lock Cap. Before installing  the cap make sure the spring is still in place. Align the three guide pins  with the three guide channels in the valve body. While maintaining  downward pressure, rotate the cap 1/6 of a turn clockwise. Once a stop   has been reached, stop pressing down. The cap spring will push the ca p  up which is the normal open position. To move to the closed position  continue to rotate the valve 1/3 clockwise.    Valve Operation  When the Fast Lock Cap is turned fully clockwise and snug against stop,  the valve is completely closed and inoperable. No fluids can be  discharged or enter the suit. When the cap is turned counterclockwise  approximately 1/3 of a turn, the valve is operational and in fully  automatic dive mode. In dive mode, fluids can be discharged at will, but   water cannot re‐enter the valve due to the one‐way check valve. The  oms pvalve manual 110216.docxoms pvalve manual 110216.docx   ...
  • Page 7 Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach    Fast Lock Cap is only closed in the event of one‐way check valve failure. It is best to check the  function of the P‐Valve system before fully gearing up and entering the water by simply  urinating.    Failure Modes  Inability to pass fluids through valve    • Cap is closed    • Connection Hose Kinked: The use of the norprene tubing has drastically reduced the  likelihood of a kinked hose. The valve is best positioned to avoid sharp bends in the hose  routing to further reduce the risk of kinking. Use only OMS® P‐Valve hose for any  replacements.    • Kink or twist in Condom Catheter: This may occur in the event that the catheter was not  properly/completely installed. Blockages in flow may be due to a sharp bend at the end  of the catheter, or a restriction created by the adhesive within the catheter. Be sure to  follow the catheter instructions carefully.    • Check Valve Failure: Debris or deposits can build up on the check valve over time and  interfere with their function. Following a periodic maintenance and cleaning schedule is  recommended.    Sea Water Entering the System    • Close Fast Lock Cap    Catheter Squeeze  • Failure of Vacuum Breaker Check valve, abort dive and/or service or replace Vacuum  Breaker Check Valve ...
  • Page 8: Warranty Information

    Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach    To inspect or replace the main umbrella valve, remove the cap.  Lift the edges of the umbrella  valve to expose the center stem. Grasp the stem firmly, and gently work it free with a side‐to‐ side rocking motion. To install a new umbrella valve, slip the center stem into the retaining hole  in the middle of the valve face. Apply gentle pressure to the center of the umbrella valve, until  it becomes fully seated. To inspect or replace the balanced check valve within the internal valve  body, use a coin to unscrew the retainer. The duckbill valve can then be removed for  inspection/replacement. When reinstalling the retainer, be sure not to over‐tighten the fitting.    Warranty Information  All warranty requests must be accompanied by proof of original purchase from an Authorized  OMS® Dealer. Be sure to save your sales receipt, and present it whenever returning your OMS®  gear for warranty service.     OMS® warrants, to the original purchaser only, that the OMS® P‐Valve will be free of defects in  materials and/or craftsmanship under normal diving use for two years from the date of  purchase, provided proper care is performed on all materials as described within this manual.  Should your P‐Valve prove to be defective for any reason it will be repaired or replaced (at  OMS® discretion) free of charge excluding shipping and handling charges.    OMS® P‐Valvespares parts  1  20918002  Valve body  2  20918003  Duckbill check valve  3  20918004  Washer (duckbill check valve) Nylon FG black 4 ...
  • Page 9 Ocean Management Systems GmbH  Klosterhofweg 96  41199 Mönchengladbach      Accessory Kit      OMS® Catheters   20916902 OMS® Catheters Med 29 mm Silicon  oms pvalve manual 110216.docxoms pvalve manual 110216.docx   ...