  • Page 1 Directions for use AeroPro ™ Cordless Prophy System Please read carefully and completely before operating unit.
  • Page 2: Table Of Contents

    6.4 Frequently Asked Questions ..... .22 6.5 Disposal of AeroPro™ Components ....23 Section 3 Your AeroPro™...
  • Page 3: General Information

    We suggest that you keep the manual available for future reference. Please take a few minutes to register your Premier AeroPro cordless handpiece as instructed in the warranty section of this manual (Section 9). By registering the unit, you ensure prompt and accurate service and support should your unit need to be repaired or replaced during the warranty period.
  • Page 4: Cautions For Handling And Operating

    Charge the cordless handpiece using only the AeroPro charging station and the supplied AC adapter. Failure to use the supplied AeroPro AC adapter might cause a malfunction and result in a void of your warranty.
  • Page 5: Precautions For Handling And Operations

    The risks of reuse of a DPA are damage to equipment and patient cross-contamination. Install a new DPA between each patient. Dispose of Premier’s 2pro (or other brand) prophy angles after each patient according to CDC Guidelines for Infectious Waste and Federal, State and Local regulations.
  • Page 6: Adverse Events

    This Class A digital apparatus complies with Canadian ICES-003. FCC ID: 2AQ77-2018-AP IC: 24334 - AEROPRO Model # AP-18-PDPC* Product Marketing Name: AeroPro System Adverse Events There are no known adverse reactions. *Refer to Section 8 for Item Numbers for Product Ordering...
  • Page 7: Your Aeropro™ Cordless Prophy System

    Your AeroPro ™ Cordless Prophy System Your System Components Confirm the AeroPro Cordless Prophy System by the REF# on the packaging and verify the following components and accessories are included. If an item is missing, call Premier Customer Experience at 888-670-6100 or 610-239-6000.
  • Page 8: Component Description

    The motor component houses the motor, gear box, power supply (lithium-ion battery) and five indicator Disinfect lights. The motor component of AeroPro is not sterilizable and is to be used only with AeroPro disposable barriers. Charging Station The charging station uses an induction charge...
  • Page 9: Assembled Handpiece Features

    Assembled Handpiece Features Special Friction Grip Nose Cone Design Positioning pin is not required allowing prophy angle to swivel. Dimpled Silicone Grip Improves tactile feel while preventing slippage. ON/OFF/SPEED MODE One Quick Touch button provides total control Easy-to-Read Indicator Lights •...
  • Page 10: Using Aeropro™ Cordless Prophy System

    5) After fully charged, follow instructions for unlocking your AeroPro handpiece Unlocking the Handpiece 4.2.1 Your AeroPro handpiece is factory shipped in a “Locked” position to prevent damage while in transit. The handpiece must be “Unlocked” prior to initial use. 4.2.2...
  • Page 11: Pre-Operational Checks

    (See images below.) PRECAUTION: Check the AeroPro™ disposable barrier for integrity before use; DO NOT use the barrier if it is damaged. Do not insert the covered motor component into the outer sheath without ensuring the AeroPro™...
  • Page 12: Operating Your Aeropro™ Handpiece

    Premier Dental Customer Experience at 888-670-6100 or 610-239-6000. Operating your AeroPro™ Handpiece 4.4.1 Before turning on the AeroPro Cordless Handpiece, make sure it is fully charged and unlocked. 4.4.2 The AeroPro Cordless Handpiece can operate at three different speeds and has two (2) optional...
  • Page 13: Changing Speed Modes

    Disassemble the handpiece for infection prevention procedure. (See Section 4.8 for instructions) 4.4.8.1 Remove outer sheath for sterilization by steam autoclaving. 4.4.8.2 Remove the AeroPro barrier from the motor component and discard it as medical waste. 4.4.8.3 Disinfect the motor component and charging station. (See Section 4.8) 4.4.9 Place disinfected motor component back into the charging station.
  • Page 14 NOTE: A smart charging management system, ChargeSMART™, allows for multiple charging throughout the day without the danger of premature battery decay. ChargeSMART™ senses when the unit is at 100% capacity and will stop the charging process to prolong battery life. RECOMMENDATION: For maximum battery life avoid running battery to empty.
  • Page 15: Locking The Handpiece

    Locking the Handpiece In the event the AeroPro cordless handpiece needs to be transported, it must first be set into the “Locked” position. The handpiece should only be locked when the indicator lights show 4 indicator lights or less Important: To lock the handpiece;...
  • Page 16 “Instructions For Disinfecting” (Section 4.8.2) The outer sheath and the stand in the AeroPro™ Cordless Prophy System are not sterile upon receipt and must be steam autoclave sterilized prior to use in accordance with the following instructions.
  • Page 17 Storage To maintain sterility, Outer Sheath/Stand should remain bagged until ready for use. In the United States, contact Premier Dental Customer Experience at 1- 888-670-6100. For Manufacturer Contact areas outside the United States call 1-610-239-6000, contact your local Premier Dental...
  • Page 18 Temperature range: -10°C to 50°C/14°F to 122°F Storage Relative humidity range: 45 - 95% (non-condensing) In the United States, contact the Premier Dental Customer Experience Team Manufacturer Contact at 888-670-6100. For areas outside the United States call 1-610-239-6000 or contact your local Premier Dental representative.
  • Page 19: System Information

    Section 5 System Information Specifications Adapter Power Supply Manufacturer: Shenzhen Ri Hua Da Electronic Co., Ltd Power Supply Model Number: RHD20W12010000U AC Input Voltage Continuous (100-240V) AC Input Current Less than 0.35A AC Input Phases Single AC Input Frequency 50-60 Hz DC Output Power DC Output Voltage and Current 12VDC at 1A...
  • Page 20: Classifications

    Charging Station, or AC Adapter) 13 5 ° Sterilize up to temperature specified Date of Manufacturing Do not reuse (for DPAs) and AeroPro Year - Month disposable barriers This product meets UL safety standard Dispose of in accordance with the Waste requirements.
  • Page 21: Maintenance, Safety Features, Troubleshooting And Frequently Asked Questions (Faq)

    Replacing O-ring on the Motor Component Replacing O-rings on the Outer Sheath Safety Features of AeroPro™ Cordless Prophy System Auto turn off of the handpiece will occur for the following reasons: 6.2.1 Overcurrent Protection: Yellow light will flash and the handpiece will automatically turn off to provide over-current protection.
  • Page 22: Troubleshooting

    During Operation 4. Check motor component. 5. Check for damaged, worn or broken components. 6. Call Premier Dental Customer Experience at 888-670-6100 or 610-239-6000 1. Check the components for gross debris. Difficulty Removing Outer Sheath 2. Hold the cordless handpiece outer sheath securely and give a slight twist to the cordless handpiece motor component.
  • Page 23 3. Verify that the cordless handpiece is able to properly sit inside the charging station for the cordless handpiece, and that there are no foreign obstructions. 4. If still not charging, call Premier Dental Customer Experience at 888-670-6100 or 610-239-6000.
  • Page 24: Frequently Asked Questions

    Frequently Asked Questions Question Answer How Long Will it Take to Fully Charge AeroPro At least 2 hours for a full charge Cordless Handpiece? How Many Prophy Polishes Can be Performed Up to 10 polishes on a Single Full Charge Without Recharging?
  • Page 25: Disposal Of Aeropro™ Components

    Disposal of AeroPro™ Components Dispose of the system components in accordance with state and local laws. Dispose of the stand, charging station and AC adapter as industrial waste according to local laws and regulations. Dispose of the outer sheath, motor component and barrier as medical waste according to local laws and regulations.
  • Page 26: Electromagnetic Compatibility Information

    Electromagnetic Compatibility Information Guidance And Manufacturer’s Declaration - Electromagnetic Emissions The AeroPro™ is intended for use in the electromagnetic environment specified below. The customer or the user of the AeroPro™ should assure that it is used in such an environment.
  • Page 27 Electromagnetic Immunity Guidance And Manufacturer’s Declaration – Electromagnetic Immunity The AeroPro™ is intended for use in the electromagnetic environment specified below. The customer or the end user of the AeroPro™ should assure that it is used in such an environment.
  • Page 28 Electromagnetic Emissions Power Line Conducted Emission Test, IEC 60601-1-2 Measuring Limits Quasi-peak Level Average Level (Group 1, Class A) (dBµv) (dBµv) Compliance level Compliance level (max Frequency (MHz) IEC60601 test level limit IEC60601 test level limit (max measured) measured) 0.15 ~ 0.50 0.50 ~ 5.00 5.00 ~ 30.00 NOTE 1: The lower limit shall apply at the transition frequencies...
  • Page 29 Guidance And Manufacturer’s Declaration - Electromagnetic Emission The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the product, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
  • Page 30: Part Numbers

    Section 8 Part Numbers Description Premier Ref Number AeroPro™ Autoclavable Outer Sheath 5500520 AeroPro™ Disposable Barriers (Box of 500) 5500530 AeroPro™ Charging Station 5500540 AeroPro™ AC Adapter 5500541 AeroPro™ Motor Component 5500550 AeroPro™ Stand 5500560 AeroPro™ O-ring Replacement Set 5500561...
  • Page 31: Limited Warranty

    Premier warrants all components of the AeroPro Cordless Prophy System against defects arising from faulty materials and workmanship for three (3) years from the date of purchase, with the exception of (i) the AeroPro Disposable Barriers and the 2pro® Disposable Prophy Angles, which are single use only items and not subject to any warranty, and (ii) the lithium-ion battery.
  • Page 32 Be your Product Concierge – for knowledge and service Make it right if we fall short Manufacturer: Premier® Dental Products Company • 1710 Romano Drive, Plymouth Meeting, PA 19462, USA Phone 888-670-6100 • 610-239-6000 • Fax 610-239-6171 • premierdentalco.com • info@premierdentalco.com Made in PRC...