Download Print this page

National Railway Supply NRS-24 Installing, Operating And Service Instructions page 3

Solid state charger

Advertisement

diagram showing the proper jumper connections for
the different AC voltages.
WARNING:
CONNECTION MAY CAUSE SEVERE DAMAGE
TO THE CHARGER AND THE BATTERY.
WARNING:
FAILURE
CONNECT THE AC VOLTAGE CONDUCTORS
COULD CAUSE SERIOUS DAMAGE TO THE
CHARGER.
IMPROPER
RESULT IN THE RISK OF AN ELECTRIC SHOCK.
DO NOT OPERATE THE CHARGER WITHOUT
PROPER GROUNDING.
6. DC OUTPUT
The DC output wires 8 AWG or larger, are
connected on the two right-most binding posts as
labeled on the panel behind the binding posts
(positive on the left and negative on the right). The
DC cables should have quarter-inch (¼") ring
terminals for connecting them to the binding posts.
Check to make sure the polarity of the DC output
wires is the same as those connected to the battery.
The charger will not operate in a reversed polarity
condition. WHEN CONNECTING THE DC WIRES
TO THE CHARGER WITH THE AC POWER
DISCONNECTED, A SPARK MAY OCCUR. This is
caused by the output capacitors being charged by
the batteries. If the DC polarity is reversed, a circuit
breaker will protect the charger from internal
damage. Correct the reversed wires and push the
circuit breaker button back in.
cover on the front of the charger after tightening all
of the binding post nuts.
WARNING:
DO
CHARGER'S TERMINALS OR AN ELECTRICAL
SHOCK COULD OCCUR.
PRESENT ON THE DC TERMINALS EVEN AFTER
THE AC IS DISCONNECTED BECAUSE OF THE
ENERGY STORED IN THE CAPACITOR.
www.nationalrailwaysupply.com
1-800-357-3572
IMPROPER
JUMPER
TO
PROPERLY
GROUNDING
CAN
Replace the door
NOT
TOUCH
THE
A VOLTAGE IS
Configure the jumpers for your AC voltage source
(refer to the jumper diagram). Place the AC ring
terminals on the binding posts and tighten the post
nuts.
7. TEMPERATURE PROBE
The external temperature probe is an optional way
of extending battery life by using temperature
compensation. One end of the temperature probe
cable has a three-pin plug, which plugs into a
receptacle labeled TEMP PROBE on the front of the
charger.
The other end of the cable has the
temperature sensor sealed either in a terminal or
small metal box.
WARNING:
IT IS IMPORTANT TO MOUNT
THE
TEMPERATURE
BATTERIES
FOR
COMPENSATION. IF THIS CANNOT BE DONE,
LOCATE THE PROBE AS LOW AS POSSIBLE IN
THE BUNGALOW OR CABINET.
Terminal-Type Probe
The terminal-type probe should be attached to the
negative (-) battery post near the center of the
battery pack. If the threaded stud is long enough
above the battery jumper nut, attach the probe with
another nut.
Torque this nut to proper specifi-
cations. If the stud is too short, the nut holding the
jumper wire will need to be removed.
remove the load and charging circuits to the
batteries. Remove the nut holding the jumper and
add the probe, then torque the nut to the proper
specifications. Then close or connect the load and
charging circuits back to the batteries.
Box-Type Probe
The metal box has a high performance contact
adhesive tape for attaching it to the battery.
attach, clean a spot for the probe on the middle
3
PROBE
ON
PROPER
TEMPERATURE
Open or
01546G
THE
To

Advertisement