  • Page 1 9292 Jeronimo Road Irvine, CA 92618-1905 HID® FlexSmart™ 609X Series Euro Readers INSTALLATION GUIDE © 2007 HID Global Corporation. All rights reserved. March 12, 2006 Document Number 6090A-901 Document Version A.1...
  • Page 2: Table Of Contents

    Wiring..........................6 Wiegand Output Timing ......................8 ABA Track 2 Magnetic Stripe Output Timing ................8 Regulatory ........................... 8 Models ............................9 Contact ............................9 Page 2 of 9 March 12, 2007 © 2007 HID Global Corporation. All rights reserved.
  • Page 3: Overview

    -40°F (-40°C) to 158°F (70°C) Operating Humidity 5% to 95% condensing Finish Black Dimensions 3.39” x 3.39” x 1.18” (86 x 86 x 30 mm) Weight 9 oz (250g) March 12, 2007 Page 3 of 9 © 2007 HID Global Corporation. All rights reserved.
  • Page 4: Mounting

    FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, A.1 Mounting Figure 2-1 – Overall Dimensions Figure 2-2 – Back Plate Dimensions Page 4 of 9 March 12, 2007 © 2007 HID Global Corporation. All rights reserved.
  • Page 5 FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, Rev A.1 Figure 2-3 – Attaching Backplate Figure 2-4 Install Reader March 12, 2007 Page 5 of 9 © 2007 HID Global Corporation. All rights reserved.
  • Page 6: Wiring

    22 AWG (0.64mm), overall foil shield, Alpha Wire 5192C series or equivalent. 500’ (152 m) 18 AWG (1.02mm), overall foil shield, Alpha Wire 5382C series or equivalent. Page 6 of 9 March 12, 2007 © 2007 HID Global Corporation. All rights reserved.
  • Page 7 Note: The shield/drain should be connected at the power supply. Connection of the shield/drain to an earth ground will provide greater ESD protection of the reader. March 12, 2007 Page 7 of 9 © 2007 HID Global Corporation. All rights reserved.
  • Page 8: Wiegand Output Timing

    This Proximity Reader is intended to be powered from a limited power source output of a previously certified power supply. This Reader is intended to be used with UL 294 Listed Control Equipment. Page 8 of 9 March 12, 2007 © 2007 HID Global Corporation. All rights reserved.
  • Page 9: Models

    +44 (0) 1440 714 840 Asia-Pacific HID Asia Pacific Ltd. (Hong Kong) support: asiasupport@hidcorp.com main: (852) 3160 9800 support: (852) 3160 9802 fax number: (852) 3160 4809 March 12, 2007 Page 9 of 9 © 2007 HID Global Corporation. All rights reserved.