The Easikey 1000 controls one or two doors, each of which may be up to 300ft/100m away from the controller. You may install the following types of readers with the EK1000. See Radionics Product Catalog (L100) for a list of components and accessories suitable for use with the Radionics Easikey 1000.
Door Monitoring Alarms (Easikey 1000 Plus Only) Easikey 1000 Plus systems can monitor door contact switches. This enables Easikey 1000 Plus systems to generate the following types of alarms: Unauthorized Access Alarms The EK1000 creates this alarm when someone opens a door without using a valid key/card, or without activating the Request to Exit device.
Identifying which version of EK1000 door controller you are installing: You can identify the difference between the Easikey 1000 or the Easikey 1000 Plus by the front keypad label. The label is marked Easikey 1000 Plus. Easikey 1000/1000 Plus The Easikey 1000 requires an enclosure and a power source.
A 12 VDC 3 Amp power supply. A 24 VDC 1.5 Amp power supply. A 16.5V AC power source at a minimum 40VA rating. Radionics offers the D1640 transformer that supplies 16.5 VAC @ 40VA. AC Power LED OFF in Editor Mode: When the AC power supply is providing power to the controller, the red LED on the controller illuminates, except when the controller is in the Editor's Mode.
No parity Hardware handshake using DTR/CTS. When the printer is busy, then it should force DTR low. Radionics has used the EPSON LX series and the OKI Microline printers with their serial board in the past. 74-07579-000-A 2/96 Page 5...
Readers You may install the following types of readers with the EK1000. See the Radionics Product Catalog (L100) for a full list of compatible readers and their part number. You may install the following types of readers with the EK1000.
Supply: 0 volts. Table 2: Terminal connections for readers Use unshielded cable: For Easikey/Readykey proximity readers, Radionics recommends that you use unshielded cable to connect the readers to the EK1000. Consider voltage drop on wire run: It is essential that on long cable runs, at least the minimum voltage is maintained at the reader.
Request to Exit device goes back to an open condition (normal) then closes again. Alarm Event Monitoring (Easikey 1000 Plus Only) If you are installing the Easikey 1000 Plus system, as an option, you can add these additional features: Door Monitoring This allows you to monitor each door by using a door contact switch.
Unauthorized Access or a Door Left Open event. Door Contact Monitoring (Easikey 1000 Plus Only) The Easikey 1000 Plus can monitor door contacts and can generate the following events: If someone forces a door open, the door controller can create an Unauthorized Access alarm.
When someone operates the break-glass switch, the power to the lock is removed causing the door to unlock without intervention from the EK1000. Alarm Output Relay (Easikey 1000 Plus Only) The Easikey 1000 Plus provides a relay on each door...
Automatic Unlock Note: The remaining displays described in this section are only applicable to the Easikey 1000 Plus version of the door controller. Door Left Open Warning (Easikey 1000 Plus Only) The EK1000 Plus door controller only gives this warning if you are using door monitoring.
12/06/95 13:37 Alarm Cleared Cable or Reader Tamper Alarm (Easikey 1000 Plus Only) The EK1000 Plus only gives this alarm if the reader has been wired to detect this condition. This alarm gives exactly the same displays and sounds as an Unauthorized Access condition.
Each door is given a Lock Release Time of five seconds. Each lock is set to fail-secure (power to unlock). If this is a new installation, Radionics recommends that the readers and locks should be tested now. If you were replacing the Maser Editor Key/Card and have preserved the existing database, the new Master Editor Key/Card is the only change.
Each Time Profile consists of up to three Time Periods, which contain the start and stop times along with the active days of the week. Separate Doors and Users: Radionics recommends that you use different Time Profiles for doors and users even if they are identical. This means that if...
Door Open Time (Easikey 1000 Plus Systems Only) This is the amount of time that the EK1000 Plus allows at the end of the Lock Release Time before the controller activates a Door Left Open warning.