Easikey
Easikey
1000 / 1000 Plus
Installation and Programming Manual
74-07579-000-A 2/96
© 1996 Radionics, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Radionics Easikey 1000 Plus

  • Page 1 Easikey Easikey 1000 / 1000 Plus Installation and Programming Manual 74-07579-000-A 2/96 © 1996 Radionics, Inc.
  • Page 2: Notices

    It is our goal at Radionics to always supply accurate and reliable documentation. If a discrepancy is found in this documentation, please mail a photocopy of the corrected material to: Radionics, Inc.
  • Page 3: Table Of Contents

    VERVIEW ............................. 1 YSTEM EATURES Access Points ............................... 1 Lock Outputs..............................1 Personnel..............................1 Time Profiles..............................1 Door Monitoring Alarms (Easikey 1000 Plus Only)..................2 Printer Facilities............................2 ............................2 YSTEM PERATION INSTALLING THE SYSTEM........................... 3 1000/1000 P ..........................3 ASIKEY EK1000 ....................
  • Page 4 ) ................16 ARNING ASIKEY Unauthorized Access Alarm (Easikey 1000 Plus Only) ................16 Cable or Reader Tamper Alarm (Easikey 1000 Plus Only) ............... 17 Alarm Relay Response (Easikey 1000 Plus Only) ..................17 PROGRAMMING THE SYSTEM........................18 ............................18...
  • Page 5 ............................... 49 OWER UTPUT ............................. 49 NVIRONMENTAL ................................49 OORS ................................49 SERS ............................. 49 RANSACTION UFFER ............................. 49 RINTER UTPUT ..............................49 ROFILES ..............................49 NCLOSURES EK1000 P ..............................49 NOTES................................50 74-07579-000-A 2/96 Page iv © 1996 Radionics, Inc.
  • Page 6: The Easikey 1000/1000 Plus

    The Easikey 1000 controls one or two doors, each of which may be up to 300ft/100m away from the controller. You may install the following types of readers with the EK1000. See Radionics Product Catalog (L100) for a list of components and accessories suitable for use with the Radionics Easikey 1000.
  • Page 7: Door Monitoring Alarms (Easikey 1000 Plus Only)

    Door Monitoring Alarms (Easikey 1000 Plus Only) Easikey 1000 Plus systems can monitor door contact switches. This enables Easikey 1000 Plus systems to generate the following types of alarms: Unauthorized Access Alarms The EK1000 creates this alarm when someone opens a door without using a valid key/card, or without activating the Request to Exit device.
  • Page 8: Installing The System

    Identifying which version of EK1000 door controller you are installing: You can identify the difference between the Easikey 1000 or the Easikey 1000 Plus by the front keypad label. The label is marked Easikey 1000 Plus. Easikey 1000/1000 Plus The Easikey 1000 requires an enclosure and a power source.
  • Page 9: Choosing The Best Location For The Ek1000

    A 12 VDC 3 Amp power supply. A 24 VDC 1.5 Amp power supply. A 16.5V AC power source at a minimum 40VA rating. Radionics offers the D1640 transformer that supplies 16.5 VAC @ 40VA. AC Power LED OFF in Editor Mode: When the AC power supply is providing power to the controller, the red LED on the controller illuminates, except when the controller is in the Editor's Mode.
  • Page 10: Installing An Optional Printer

    No parity Hardware handshake using DTR/CTS. When the printer is busy, then it should force DTR low. Radionics has used the EPSON LX series and the OKI Microline printers with their serial board in the past. 74-07579-000-A 2/96 Page 5...
  • Page 11: Printer Cable

    If you use the EK12 Wiegand Interface, connect it to the EK1000 at the terminal connectors 23-26 located on the bottom left edge of the EK1000. Figure 4: Connecting the EK12 Wiegand Interface to the EK1000 74-07579-000-A 2/96 Page 6 © 1996 Radionics, Inc.
  • Page 12: Using Wiegand Device Readers

    Readers You may install the following types of readers with the EK1000. See the Radionics Product Catalog (L100) for a full list of compatible readers and their part number. You may install the following types of readers with the EK1000.
  • Page 13: Wiegand Reader Wiring

    Supply: 0 volts. Table 2: Terminal connections for readers Use unshielded cable: For Easikey/Readykey proximity readers, Radionics recommends that you use unshielded cable to connect the readers to the EK1000. Consider voltage drop on wire run: It is essential that on long cable runs, at least the minimum voltage is maintained at the reader.
  • Page 14: Mounting The Reader

    Request to Exit device goes back to an open condition (normal) then closes again. Alarm Event Monitoring (Easikey 1000 Plus Only) If you are installing the Easikey 1000 Plus system, as an option, you can add these additional features: Door Monitoring This allows you to monitor each door by using a door contact switch.
  • Page 15: Door Contact Monitoring (Easikey 1000 Plus Only)

    Unauthorized Access or a Door Left Open event. Door Contact Monitoring (Easikey 1000 Plus Only) The Easikey 1000 Plus can monitor door contacts and can generate the following events: If someone forces a door open, the door controller can create an Unauthorized Access alarm.
  • Page 16: Fire Escape Safety

    When someone operates the break-glass switch, the power to the lock is removed causing the door to unlock without intervention from the EK1000. Alarm Output Relay (Easikey 1000 Plus Only) The Easikey 1000 Plus provides a relay on each door...
  • Page 17: Free Exit And Emergency Override Option

    Think "Fire Safety": You should not use Emergency Override as the sole means of escape. Even if this feature is being used it is still necessary to provide a manual means of exit. 74-07579-000-A 2/96 Page 12 © 1996 Radionics, Inc.
  • Page 18: Operating The System

    Editor Time-out If after entering the Editor, no one presses any keys on the keypad or presents a key/card to the EK1000's internal reader for three minutes, the Editor will 'time- 74-07579-000-A 2/96 Page 13 © 1996 Radionics, Inc.
  • Page 19: How To Use The Ek1000 Keypad And Editor Mode

    Whenever you add or change any data item you must press SEL/SAVE to confirm and accept the changes. You can press ESC to leave the data unaltered. 74-07579-000-A 2/96 Page 14 © 1996 Radionics, Inc.
  • Page 20: System Displays And Alarms

    Whenever a door is opened normally or automatically, either with a key/card or by using a request-to-exit button, the display will look as shown here in Figure 10 Door 1 Open Door 2 Open Both Doors Open Figure 10: Normal displays 74-07579-000-A 2/96 Page 15 © 1996 Radionics, Inc.
  • Page 21: Door Left Open Warning (Easikey 1000 Plus Only)

    Automatic Unlock Note: The remaining displays described in this section are only applicable to the Easikey 1000 Plus version of the door controller. Door Left Open Warning (Easikey 1000 Plus Only) The EK1000 Plus door controller only gives this warning if you are using door monitoring.
  • Page 22: Cable Or Reader Tamper Alarm (Easikey 1000 Plus Only)

    12/06/95 13:37 Alarm Cleared Cable or Reader Tamper Alarm (Easikey 1000 Plus Only) The EK1000 Plus only gives this alarm if the reader has been wired to detect this condition. This alarm gives exactly the same displays and sounds as an Unauthorized Access condition.
  • Page 23: Programming The System

    If this is an existing installation and you do not want to erase the database, then just press ESC. Use this step if you are just replacing the Master Editor Key/Card. The display clears and the EK1000 replaces the Master Editor Key/Card. 74-07579-000-A 2/96 Page 18 © 1996 Radionics, Inc.
  • Page 24: Testing The Master Editor Key/Card And System

    Each door is given a Lock Release Time of five seconds. Each lock is set to fail-secure (power to unlock). If this is a new installation, Radionics recommends that the readers and locks should be tested now. If you were replacing the Maser Editor Key/Card and have preserved the existing database, the new Master Editor Key/Card is the only change.
  • Page 25: Installing And Voiding Additional Sub Editor Key/Cards

    Sub Editor number will flash. You may add more Sub Editors now if you wish by repeating Steps 5-7. Press ESC if you are finished programming Sub Editors. Press ESC to leave Editor. SEL? 74-07579-000-A 2/96 Page 20 © 1996 Radionics, Inc.
  • Page 26: Voiding An Sub Editor Key/Card

    Sub Editor Key/Card. There will be a short beep and the display will return to "SEL?". Return to Step 2 above to delete more Sub Editor SEL? Key/Cards or press ESC to leave the Editor. 74-07579-000-A 2/96 Page 21 © 1996 Radionics, Inc.
  • Page 27: Setting The Clock

    Change the time for Daylight Savings Time: The EK1000 follows a true calendar year and recognizes leap year, but does not observe Daylight Savings Time so you may need to make local time adjustments for Daylight Savings Time. 74-07579-000-A 2/96 Page 22 © 1996 Radionics, Inc.
  • Page 28: Time Profiles And Time Periods

    Each Time Profile consists of up to three Time Periods, which contain the start and stop times along with the active days of the week. Separate Doors and Users: Radionics recommends that you use different Time Profiles for doors and users even if they are identical. This means that if...
  • Page 29: 24-Hour Operation

    When you press a number keyed to make a change, the display will go steady. Changes are made as follows: Change the status by pressing the 1 key, for example, pressing 1 reverses the current display. Press SEL/SAVE when the EK1000 displays the correct status. 74-07579-000-A 2/96 Page 24 © 1996 Radionics, Inc.
  • Page 30 Saturday only would be represented as a vertical bar in the sixth position going from left to right. Changed each bar by pressing 1-7, where 1 represents Monday, 2 Tuesday, through 7 for Sunday. 74-07579-000-A 2/96 Page 25 © 1996 Radionics, Inc.
  • Page 31 Press t1Ad / The display now shows the begin time t1bb / 0800 of period B. As an example type 0800 for 8am followed by SEL/SAVE to confirm the change. 74-07579-000-A 2/96 Page 26 © 1996 Radionics, Inc.
  • Page 32 Time Profile 1. Press ESC twice to leave Editor or repeat the step 3-19 for the other Time Profiles that you are using. This completes the setting up of a complete Time Profile. 74-07579-000-A 2/96 Page 27 © 1996 Radionics, Inc.
  • Page 33: Programming The Door Data

    Door Open Time (Easikey 1000 Plus Systems Only) This is the amount of time that the EK1000 Plus allows at the end of the Lock Release Time before the controller activates a Door Left Open warning.
  • Page 34: Free Exit/Emergency Override

    Presenting a key/card to the reader releases (engages) the lock output. It stays in this state until a user presents a key/card again to the reader, then the lock output will disengages. 74-07579-000-A 2/96 Page 29 © 1996 Radionics, Inc.
  • Page 35: Using The Doors Function

    See Manual Lock/Unlock for Controlling the Doors on page 32 section for full details of use. Press ESC twice to leave Editor or repeat the step 3-7 for entering the door parameters for door 2. 74-07579-000-A 2/96 Page 30 © 1996 Radionics, Inc.
  • Page 36: Channel Interlock

    This feature is often referred to a “Forgiveness Time.” 74-07579-000-A 2/96 Page 31 © 1996 Radionics, Inc.
  • Page 37: Programming Anit-Passback

    Time Profile assigned. Doors not controlled by a Time Profile Manual unlock will unlock the door and it will stay unlocked until manually locked again. 74-07579-000-A 2/96 Page 32 © 1996 Radionics, Inc.
  • Page 38: To Lock/Unlock A Door

    Time Profile. If the first dot is illuminated (left), that key/card will have access to door 1, the second dot (right) indicates access to door 2. If neither dot is illuminated, the key/card is locked out and will not be allowed access through either door. 74-07579-000-A 2/96 Page 33 © 1996 Radionics, Inc.
  • Page 39: User (Key/Card) Numbers

    LEDs steady, free numbers will alternate with their Time Profile and Access Level and the green LED flashing. Press SEL/SAVE to confirm the number that has been chosen. 74-07579-000-A 2/96 Page 34 © 1996 Radionics, Inc.
  • Page 40 0020 / t1 . and the next available number will flash. If you wish to add more keys see Adding Several Key/Cards next otherwise press ESC. Press ESC to leave Editor. SEL? 74-07579-000-A 2/96 Page 35 © 1996 Radionics, Inc.
  • Page 41: Adding Several Keys

    Editor’s possession. Edit the key/card using the following procedure. Step Example Display Action Present an Editor key/card to the EK1000’s internal reader. Press the KEY/4 key. SEL? 74-07579-000-A 2/96 Page 36 © 1996 Radionics, Inc.
  • Page 42: Displaying A Key/Card Pin Number

    PIN Number. The PIN Number displayed. 1234 The EK1000 does not assign the PIN Number: You cannot change the PIN. It is contained within the key/card and not programmable. 74-07579-000-A 2/96 Page 37 © 1996 Radionics, Inc.
  • Page 43: Identifying A Key/Card

    SEL/SAVE to confirm. Valid key/cards that are present in the database will flash along with the red LED, Invalid key/cards will flash with red and green LEDs steady. 74-07579-000-A 2/96 Page 38 © 1996 Radionics, Inc.
  • Page 44: Additional System Options

    The “?”s represent the version software number. In this case the display shows version 1.00,. v100 This is the software revision for this EK1000. Press ESC. SEL? Press ESC to leave Editor. 74-07579-000-A 2/96 Page 39 © 1996 Radionics, Inc.
  • Page 45: Upload/Download Option

    / nnn / in display oUt alternating with the percentage complete. The receiving controller will flash When complete, both displays will return to SEL? Press ESC to leave Editor. SEL? SEL? 74-07579-000-A 2/96 Page 40 © 1996 Radionics, Inc.
  • Page 46: Display Last Five Keys Or Cards Used

    Request to Exit [0061] 01/06/95 12:19 0045 Access Authorized [0062] 01/06/95 12:23 0045 Access Authorized [0063] 01/06/95 12:30 Automatic Unlock [0064] 01/06/95 12:33 0120 No Access: Time [0064] 01/06/95 12:42 Unauthorized Access 74-07579-000-A 2/96 Page 41 © 1996 Radionics, Inc.
  • Page 47: Transaction Event Definitions

    The door has closed again after being left open. EK1000 Plus Only RTE Button Held Down The RTE switch is being held down. Repeated Token Use The same key/card has been presented more than 5 times in succession the reader. 74-07579-000-A 2/96 Page 42 © 1996 Radionics, Inc.
  • Page 48: No Access

    Special use of Request to Exit. The switch is monitoring an emergency switch (e.g. a break glass). Unit Closed Down Power removed from the EK1000. Unit Started Up The EK1000 has been switched on. 74-07579-000-A 2/96 Page 43 © 1996 Radionics, Inc.
  • Page 49: Printing Reports

    Press the PRINT/8 key SEL? Press SEL/SAVE to start database printout. PrdA ..printing personnel database / Prnt ..printing Time Profiles ..printing door data / Prnt / Prnt Press ESC to leave Editor. SEL? 74-07579-000-A 2/96 Page 44 © 1996 Radionics, Inc.
  • Page 50: Sample Database Printout

    OPTIONS = Reverse Lock, Request to Exit DOOR = Locked Door 2 LOCK TIME = 005 DOOR TIME = 010 TIME PROFILE = 0 OPTIONS = Request to Exit DOOR = Locked 74-07579-000-A 2/96 Page 45 © 1996 Radionics, Inc.
  • Page 51: Printing Selected Key/Card Transactions

    Press the CLrt Press SEL/SAVE to confirm. /ALL? Press VOID/5 followed by SEL/SAVE to erase all transactions from memory. There will be a short confirming beep. Press ESC to leave the Editor. SEL? 74-07579-000-A 2/96 Page 46 © 1996 Radionics, Inc.
  • Page 52: Glossary

    An electronic identification device containing a unique code. This device is held near to a Readykey reader to allow the code to be read, the door controller then decides whether to release the lock. 74-07579-000-A 2/96 Page 47 © 1996 Radionics, Inc.
  • Page 53 Unauthorized Access A special kind of alarm transaction which occurs when a door is opened without a valid key being presented to the reader, or the request to exit switch being pressed. 74-07579-000-A 2/96 Page 48 © 1996 Radionics, Inc.
  • Page 54: Specifications

    Connect up to two doors Optional Anti passback Optional Channel Interlock Optional set / reset Users Assign up to 1000 key/cards to the system Transaction Buffer Up to 1000 events stored for printing 74-07579-000-A 2/96 Page 49 © 1996 Radionics, Inc.
  • Page 55: Notes

    Notes 74-07579-000-A 2/96 Page 50 © 1996 Radionics, Inc.