Cadent iTero EID-2 Operation Manual

Optical impression device

Advertisement

Quick Links

EID-2 Optical Impression Device
Operation Manual
iTero Mobile Cart
Publication SD08300-A
Revision 1.05
December 26, 2006
Optical Impression System for Computer Assisted Design and Manufacturing
(510K exempt under 21 CFR 872.3661)
DIGITAL IMPRESSION DEVICE

Advertisement

Table of Contents
loading

Summary of Contents for Cadent iTero EID-2

  • Page 1 EID-2 Optical Impression Device Operation Manual iTero Mobile Cart Publication SD08300-A Revision 1.05 December 26, 2006 Optical Impression System for Computer Assisted Design and Manufacturing (510K exempt under 21 CFR 872.3661) DIGITAL IMPRESSION DEVICE...
  • Page 2 Cadent. TRADEMARKS Cadent, OrthoCAD, iTero, EID-1, EID-1 Optical Impression Device, EID2, EID-2 Optical Impression Device, OrthoCAD iQ, OrthoCAD Set-Up, OrthoCAD Bracket Placement and OrthoCAD Bracket Placement Video System are trademarks or registered trademarks of Cadent.
  • Page 3 Operation Manual EID-2 Optical Impression Device SYMBOLS Caution! - Wherever this symbol appears on the equipment, it is recommended to refer to the instructions in this Operator’s Guide. Applied part type B. Any device on which this symbol appears is electric isolation type B. CLASS 1 LASER COMPLIANCE This product complies with “21 CFR 1040.10”...
  • Page 4  Refrain from opening any closed components. Except for the replacement of batteries in the mouse and foot pedal, all closed components should be serviced by authorized Cadent technicians only.  The EID-2 system is intended for indoor usage only and should not be exposed to direct sunlight.
  • Page 5: Table Of Contents

    Operation Manual EID-2 Optical Impression Device Table of Contents Chapter 1: Introduction ......................7 Overview ..........................7 The Digital Crown Production Process ................... 7 About the iTero Service ......................8 Chapter 2: Operating Instructions ..................9 First Time Usage ........................9 Booting System ........................
  • Page 6 EID-2 Optical Impression Device Operation Manual This page is intentionally blank. Publication SD08300-A (Rev. 1.05)
  • Page 7: Chapter 1: Introduction

    STEP 2: Upload Case to Cadent Upload the case to Cadent for processing based on your choice of materials and color. Cadent receives the case, performs crown design, and then sends the case to the lab technician for viewing and editing.
  • Page 8: About The Itero Service

    Operation Manual About the iTero Service Cadent’s iTero service has introduced to the dental industry a breakthrough technology in the field of digital crown production. The iTero technology makes it possible to perform an intra-oral digital scan in the office and to produce a precise crown based on the digitally acquired data.
  • Page 9: Chapter 2: Operating Instructions

    (for example, if the system was unattended during a power out). Following the 24-hour charge period, it‘s recommended to leave the system running during all office hours to allow background file transfer with Cadent. Booting System Press the front POWER switch.
  • Page 10: Using The Itero Software

    OFFICE help. The iTero Case Manager works interactively with iTero OFFICE and handles file communications between the doctor’s office and the Cadent Center. For more information, press F1 to activate the iTero Case Manager help. The Cadent support icon enables Cadent technical support to provide remote training and support.
  • Page 11: Disinfecting Scanner And Replacing Disposable Sleeve

    Operation Manual EID-2 Optical Impression Device Disinfecting Scanner and Replacing Disposable Sleeve To avoid cross contamination between patients, the scanner must be disinfected and the disposable plastic sleeve must be replaced. First use disinfectant wipes to clean the scanner arm, cradle, keyboard and mouse. Then proceed with the steps below in order to replace the disposable sleeve.
  • Page 12: Using The Foot Pedal Unit

    EID-2 Optical Impression Device Operation Manual Using the Foot Pedal Unit USING THE PEDALS The foot pedal unit contains two pedals for activating the scanning sequence and responding to screen questions. The colors of the two foot pedals match the Pedals dialog in the iTero OFFICE application (right is green, left is red).
  • Page 13: Chapter 3: Cart Features

    Operation Manual EID-2 Optical Impression Device Chapter 3: Cart Features This chapter describes the external hardware components of the EID-2 system. Front View of Cart Flat LCD monitor can be swiveled freely in any direction. Optical scanner for capturing teeth images. Note that the handheld scanner may be placed in scanner cradle in either direction (right-to-left or left-to-right).
  • Page 14: Back View Of Cart

    EID-2 Optical Impression Device Operation Manual Back View of Cart Air Vent Air Vent (do not block) (do not block) Main AC Power Cable Main Power Shut Off For Shipping or Storage When you need to unplug the cart for an extended period of time, perform these steps: Close all files and applications.
  • Page 15: Cleaning Monitor

    Operation Manual EID-2 Optical Impression Device Cleaning Monitor (1) Shut down the system using the front POWER switch to ensure that no power is being supplied to monitor. (2) Lightly dampen a clean white cotton cloth with water and wipe monitor clean. (3) Dry the monitor immediately using a clean white cotton cloth.
  • Page 16: Locking Wheels

    EID-2 Optical Impression Device Operation Manual Locking Wheels Each of the four wheels can be locked or unlocked individually. LOCK WHEEL Step down on lever to lock wheel. UNLOCK WHEEL Raise lever to unlock wheel. Publication SD08300-A (Rev. 1.05)
  • Page 17: Appendix A: Hardware Specifications

    Operation Manual EID-2 Optical Impression Device Appendix A: Hardware Specifications ITEM DESCRIPTION Monitor LCD 19” monitor meets FCC and safety approval (UL, CSA, TUV) and operates at 1280x1024 resolution. Handheld Scanner Emits red laser light for performing tooth scan (660 nm Class 1). Also emits colored lights for performing a colored scan.

Table of Contents