SpiderAlert SPD-2000 NS Installation Instructions

Supervised rfid spatial position detector

Advertisement

Quick Links

SPD-2000 NS
Supervised RFID Spatial Position Detector

INTRODUCTION

The SPD-2000 NS is a fully supervised RFID spatial position detector
from Visonic Technologies (VT). The SPD-2000 NS is ideal for
protecting fine art in public instutions, museums, galleries or private
residences.
The SPD-2000 NS detector is designed to descretly and covertly
protect, location monitor and identify all types of fine art assets
including paintings, statues, antiques and ceramics in environments
where conventional security systems are not quite adequate.
The SPD-2000 NS is also suitable for high-risk, stationary general
asset protection; including but not limited to computers, general office
and medical equipment. When deployed as part of a 'SpiderAlert'
system, the SPD-2000 NS can provide on-going around-the-clock
asset location monitoring in near-real time (30 second intervals).
Each SPD-2000 NS detector is deployed with its own 24-bit
identification code (factory set) so that each asset is protected by a
uniquely numbered tag.
The SPD-2000 NS contains an ultra-sensitive acceleration sensor
(silicone chip mounted) that measures on two axes static (vibration)
as well as dynamic (gravity) accelerations. Thus when a protected
asset is moved without authorization, the SPD-2000 NS transmits a
real-time identifiable coded alarm message every 30 seconds while in
motion to the 'SpiderAlert' system. Each alarm transmission consists
of three messages (each message @ 300ms in duration), at 700ms
intervals. Thus the total duration of an alarm transmission is
approximately 2300ms.
The SPD-2000 NS automatically transmits an alarm restore message
when the asset is again at rest or after 10 minutes has elapsed
without detecting further acceleration changes so that the system can
handle new alarm conditions. The SPD-2000 NS returns to
generating a single supervision transmission at @ 15min. intervals for
a maximum of 5 messages/hr. Each supervison transmission consists
of a single message (@ 300ms in duration). Accordingly, total
duration of supervision transmissions /hr is @ 1500ms.
To
ensure
high
operational
environments, the SPD-2000 NS automatically transmits supervisory
status messages at 15 minute intervals or 60 minute intervals
depending on the enabled mode selection position of Function Switch
2 (as detailed table 1) to the 'SpiderAlert' system throughout the day.

SPECIFICATIONS

Movement Sensitivity: 0.075g (Gravitation accel. Constant)
Transmission Frequency (MHz): 315, 433.92, 447.375,
868.95, 869.025 or other frequencies according to local
requirements
Transmission range: Up to 60m (200 ft.) from the receiver in
open indoor spaces and 30m (100 ft.) in sub-divided rooms
(In environments that includes metals, the effective transmission
range may drop significantly.)
Overall Message Length: 36 bit pulse width modulation,
including 24-bit identification code
Supervision : Supervisory status messages transmitted
continously at 15 minute intervals or 60 minute intervals
depending on the enabled mode selection of Function
Switch 2 as detailed in Table 1.
Power Source: 3 V Lithium Thionyl Chloride (LiSOCl
battery, size 1/2 AA, Tadiran TL-2150, or equivalent
Nominal Battery Capacity: 1 Ah
Page 1 of 3
DE3650
reliability
in
security
sensitive
)
2
Installation Instructions
The SPD-2000 NS is also tamper protected. Upon removing the unit's
cover, the detector automatically transmits a Tamper alarm in near-
real time (30 second intervals) as an alarm tracking transmission.
Should the SPD-2000 NS not detect further acceleration changes
after 10 minutes has elapsed, the detector returns to generating a
single transmission @ every 15 minutes, comprised of three alarm
messages the same as described above.
The SPD-2000 NS employs a
"Smart" anti-collision transmission
methodogy to overcome message
collisions from other RFID
detectors in the protected area.
Operating power is provided by single onboard commercially
available 3.0 V 1/2 AA Lithium battery. When battery voltage is low, a
"Low Battery" marker is added to the transmitted message.
A LED illuminates upon all event transmissions (except for a low
battery condition).
SPD-2000 NS Advantages:
• Quick and easy installation. The sensor attaches to
an asset using double-sided adhesive tape or via an
optional mounting bracket.
• Supports four user selectable sensitivity levels for
detecting unauthorized asset movement.
• Powered by a single, compact 3V Lithium battery,
• Small size, enables descrete, covert asset mounting.
• Optional Alarm Tracking delivers near-real time
(30 second intervals) location monitoring of the
protected asset.
Current Drain: 500 µA (STBY), 20 mA (transmission, including
LED)
Alarm Tracking: Automatic signaling at 30 second intervals
when the protected asset is in unauthorized motion
Battery Life: At least 2 years (typical operation)
Battery Supervision: Automatic Low battery condition marker
is automaticly added to transmitted messages
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Dimensions (Height x Width x Depth): 72 x 49 x 18.5 mm
(2-13/16 x 1-15/16 x 11/16 inches)
Weight (excluding battery): 50 g (1.75 oz)
Color: Black
Compliance Standards: Meets FCC Part 15, ETS 300-220
and MPT1349
The 433.92 MHz models of this device comply with the
European Council Directive EMC 89/336/EEC & 92/31/EEC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPD-2000 NS and is the answer not in the manual?

Questions and answers

Summary of Contents for SpiderAlert SPD-2000 NS

  • Page 1 Installation Instructions Supervised RFID Spatial Position Detector INTRODUCTION The SPD-2000 NS is also tamper protected. Upon removing the unit's The SPD-2000 NS is a fully supervised RFID spatial position detector cover, the detector automatically transmits a Tamper alarm in near- from Visonic Technologies (VT).
  • Page 2 CAUTION: To eliminate the risk of possible explosion, do not attempt to replace the battery with a non-specified type. Attach the SPD-2000 NS to a corner of the asset you wish to protect using double-side adhesive tape or by means of an optional mounting bracket.
  • Page 3 SPD-2000 NS - Installation Instructions STANDARDS COMPLIANCE This device complies with Part 15 of the FCC Rules and RSS- However If this equipment does cause harmful interference 210 of Industry and Science Canada. to radio or television reception, which can be determined by...

Table of Contents