AMANTI Technologica Instruction Manual

Espresso machine

Advertisement

Quick Links

AMANTI Technologica
AMANTI Technologica
Espresso Machine Manual
Congratulations on your purchase of an AMANTI Technologica®, the world's best espresso machine.
The Technologica® espresso machine is a special machine, with
one big 12 litre boiler for making steam and hot water; and,
o
one mini-boiler for each group/handle for making coffee
o
So for example a two group/handle Technologica® has
three boilers.
The main boiler works as a normal boiler, like in a
normal espresso Machine, but the mini-boilers are
completely independent, with separate, independent
electronic temperature controllers.
This document highlights the main features of the
Technologica®

Table of Contents

Installation Considerations ................................ ................................ ................................ ............. 2
Power Saving Heat Up Selector Switch ................................ ................................ ......................... 5
Main Power Switch ................................ ................................ ................................ ....................... 5
Orange Push Button Group Switch ................................ ................................ ................................ 5
Electronic Group Temperature Controllers ................................ ................................ .................... 5
Pressure Gauges ................................ ................................ ................................ ............................ 6
Espresso Brewing ................................ ................................ ................................ .......................... 6
Heating and Foaming Milk with Steam ................................ ................................ .......................... 6
Hot Water ................................ ................................ ................................ ................................ ...... 6
Espresso Extraction ................................ ................................ ................................ ....................... 6
Programming Espresso Dosages ................................ ................................ ................................ .... 6
Pre-Infusion ................................ ................................ ................................ ................................ ... 7
Programming Hot Water for Tea and Long Blacks ................................ ................................ ........ 7
Boiler Level Probe ................................ ................................ ................................ ......................... 7
Automatic Water Filling ................................ ................................ ................................ ................ 7
Water Pump ................................ ................................ ................................ ................................ ... 7
Programming Temperature Controllers ................................ ................................ .......................... 7
Main Boiler Draining ................................ ................................ ................................ ..................... 8
Reset Procedure for 'Change Water Filter' Reminder Display ................................ ....................... 9
Electronic Control Features & Programming ................................ ................................ ............... 10
Trouble Shooting ................................ ................................ ................................ ......................... 12
l
1
-
8
0
0
-
F
R
E
E
c
a
l
l
1
-
8
0
0
-
C
O
F
F
E
E
T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc
Instruction Manual
®
A
M
A
N
T
I
f
.
c
o
f
f
e
e
.
c
World's Largest Espresso Machine
x
1
-
8
o
m
F
R
E
E
f
a
x
1
-
8
®
A
M
A
N
T
I
A
M
A
N
T
I
0
0
-
0
0
-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Technologica and is the answer not in the manual?

Questions and answers

Summary of Contents for AMANTI Technologica

  • Page 1: Table Of Contents

    AMANTI Technologica ® Espresso Machine Manual Congratulations on your purchase of an AMANTI Technologica®, the world’s best espresso machine. The Technologica® espresso machine is a special machine, with one big 12 litre boiler for making steam and hot water; and, one mini-boiler for each group/handle for making coffee World’s Largest Espresso Machine...
  • Page 2: Installation Considerations

    The machine should be protected by an approved and appropriate electrical fuse and earth leakage detector. In the event that the main power cord is not long enough, the cord should be replaced by an AMANTI authorized technician. The water connection to the machine should be through a tap so that the water supply to the machine can be turned off.
  • Page 3 This will keep the handles and cups hot and ready for use. Wait until the machine develops sufficient main boiler pressure at about 0.7 bar or more. The Technologica® takes about 10 minutes to heat with a 30 Amp power supply, 20 minutes with a 20 Amp power and about 40 minutes on 10 Amps of power.
  • Page 4 Make sure the steam arm is pointing in a safe direction before opening the steam tap. Note The Technologica® may be fitted with a quarter turn ceramic tap or a rubber was her compression tap. Preparing Tea and Herbal Infusions The Technologica®...
  • Page 5: Power Saving Heat Up Selector Switch

    Position: Lower right side, black in colour. Use: Switches the machine “on”. The Technologica® can be configured to operate on 30, 20 and 10 Amps by disconnecting one or two main boiler elements. On full power, the main steam boiler takes about 10 minutes to heat up, on 20 Amps (one boiler element disconnected) heat up time is about 20 minutes and on 10 Amps (two boiler elements disconnected) heat up time is about 40 minutes.
  • Page 6: Pressure Gauges

    Some Technologica® models have a water mixer, i.e. a tap which mixes cold water with the boiling water at the hot water spout so the temperature of the water dispensed can be lowered so as not to burn the coffee for a long black.
  • Page 7: Pre-Infusion

    A boiler fill LED informs the operator of boiler filling. The Technologica® uses Procon brand pumps that are very reliable. Usually, espresso machines are connected to a mains water supply. If the operator wishes to use tank water, a one way valve is recommended to prevent water return to the tank.
  • Page 8: Main Boiler Draining

    Then, the PID program will wok together with the element to maintain the set point temperature inside the mini-boiler. Robusta beans require a higher brew water temperature arount 95º C whereas AMANTI Super-Gourmet, 100% specialty beans require a brew water temperature of only 89º C If the boiler is not used for dispensing much hot water, then it is recommended to drain the main boiler from time to time, to clear water impurities that may accumulate in the main boiler.
  • Page 9: Reset Procedure For 'Change Water Filter' Reminder Display

    2) Do the following on the LEFT hand Group Touch-Pad 3) Press and hold '2 Short Coffees' AND '2 Long Coffees' button 4) While pressiong both buttons at the same time, turn the Technologica 'ON' New Display ----------------> FILTER RESET...
  • Page 10: Electronic Control Features & Programming

    Low / Medium / High (for tank water) 14- Service Call Counter "Star"=Menu Service cycles XXXXX to be adjusted by technician 15- Electronic Boiler Control "Star"=Menu Temperature Xº Not used when a pressurestat is controlling the boiler elements T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc...
  • Page 11 19- Boiler Fill Time-Out "Star"=Menu TIME-OUT FILLING UP XX 20- Water Filter Litre Monitor "Star"=Menu WATER FILTER XXX Set Litres cartridge lifespan. Assumes 30ml per shot. Monitors shots only not hot water. T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc...
  • Page 12: Trouble Shooting

    These cases need better the intervention of a technician Inconsistent Brewing (too long) Control that the volumetric meter-counter generates impulses. Change it if necessary. Verify the volumetric meter-counter connection. If the volumetric counter generates impulses, substitute the electronic switchboard. T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc...
  • Page 13 The cases 5 and 6 can be solved by the owner. Others better a technician Electronics led blinking of the selected dosage If the coffee usually comes out, but the cycle doesn't stop, don’t reprogram the machine. T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc...
  • Page 14 For further information, contact with your technical service. The case 1 can be solved by the owner. Others better technician Hot water faucet Leak of water (manual water fill) T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc...
  • Page 15 See "the machine doesn't pressurize" “ and “leak of water” The case 1 can be solved by the owner. Others better technician M.F.M., S.L. reserves the right to modify this manual without prior warning T:\Photos Digital\Coffee Equipment - New Ours\Technologica\Technologica Instruction Manual 080304.doc...

Table of Contents