Kobra - Tongue Switches with Guard Locking - Type KL3-SS-P2L
Internal Terminal Connections:
Internal Terminal Connections:
A1
0V dc
A2
24V.dc
11-12
Safety Circuit 1 – (must always be used)
21-22
Safety Circuit 2
33-34
Signal Circuit Guard - (Closed when Guard is closed)
43-44
Signal Circuit Guard - (Closed when Guard is open)
LED Function:
Green
Solenoid Energised
Standards:
Solenoid Voltage
Solenoid consumption – Turn on current
Running current
Safety Contacts
11-12
21-22
Utilization Category
Thermal Current (Ith)
Rated Insulation Voltage
Rated Impulse Withstand Volt
Signal Contacts 33-34
43-44
Travel for Positive Opening
Man. Actuation Frequency
Actuator entry minimum radius
Case Material
Actuator Material
Enclosure Protection
Operating Temperature
Mechanical Life Expectancy
Vibration
Conduit Entry
Fixing
Information with regard to UL 508:
Type 1 Enclosures.
Use 16-12AWG copper conductors only.
Intended for same polarity use and
one polymeric conduit connection.
Electrical Rating: A300. 48W5.
Max. Switching Current / Volt / Amp:
120V. 6A. (720VA break) PF 0.38
240V. 3A. (720VA break) PF 0.38
IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR UK. Tel: +44 (0)1942 257070
IDEM (USA) 4416 Technology Drive, Fremont, CA 94538 Tel:510-445-0751 Fax:1866-431-7064 email:
EN1088, IEC 60947-5-1, UL508
24V dc
1.2 A.
0.3A.
AC15 A300 3A.
5A
600VAC
2500VAC
AC15 A300 3A.
10mm
2 cycle/sec
175mm
Stainless steel 316
Stainless steel 316
IP69K
-25°C to 40°C
1 x 10
6
Cycle min.
IEC 68-2-6, 10-55Hz+1Hz,
Excursion: 0.35mm, 1 octave/min
M20 or ½" NPT (by Part Number)
4 x M5
Actuator insertion:
6.0
5
11/12
Open
Solenoid energised
21/22
Open
Solenoid energised
33/34
Closed
Locked
43/44
Open
sales@idemsafety.com
0mm
Tongue Inserted