Please read this guide before installing, using the product, or performing any main- tenance operation. Failure to read, understand and follow herein instructions may result in personnal injury. In no event shall HIKOB be held liable for any damages arising out of or related to misunderstanding instructions detailed in this manual.
– IEC 60950-1:2005 + A1:2010 + A2:2013 – EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 The HIKOB WISE COW is certified to follow the IEC 60 950-22 Am2 outdoor safety stan- dard. With exception for Finland, Norway and Sweden, countries where environment temper- ature can be far lower than the limit for operating and safety assurance temperatures for the HIKOB WISE COW.
HIKOB WISE COW Version 1.1-2466 undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
HIKOB WISE COW Version 1.1-2466 1.4 WEEE Information on disposal for users of waste electrical electronical equipment: This symbol on the product(s) and / or accompanying documents means that used electrical and electronic products should not be mixed with gen- eral household waste.
Should you decide to perform cleaning tasks on the HIKOB WISE COW while it’s still not bur- ried, don’t perform high pressure cleaning, prefer wiping with a dry cloth, or with a neutral agent.
IEEE 802.15.4e Protocol Antenna gain +3dBi Input level sensivity -101dBm Output power +4dBm Range to router or gateway Radio range given for a HIKOB WISE COW sensor once installed in the road, see section Installation. November 2015 Page 8/ 14...
HIKOB WISE COW Version 1.1-2466 4 Installation You need one HIKOB WISE COW Parking sensor per parking spot, and two HIKOB WISE COW Traffic sensors per traffic line to measure speed. Here are HIKOB recommendations to draw your installation map: Figure 2: Truck parking Figure 3: Traffic...
HIKOB WISE COW Version 1.1-2466 4.1 Installation Procedure Installing HIKOB WISE COW sensors requires the use of a specific polyurethane resin provided by HIKOB. For good results in sealing, environment temperatures must not be below +5°C. 4.2 Tools Here are the tools you need to install HIKOB WISE COW sensors:...
HIKOB WISE COW Version 1.1-2466 Vacuum cleaner Blowtorch Glue gun 4.3 Step-by-step installation procedure 1 Mark and protect your working area. November 2015 Page 11/ 14...
Page 12
HIKOB WISE COW Version 1.1-2466 2 Locate the HIKOB WISE COW position on the ground and and draw a sign, according to your installation doc- uments. 3 Drill a hole: HIKOB WISE COW sensors are installed in road pavements by core drilling the asphalt 65mm deep, with a 65mm diameter minimum.
Page 13
HIKOB WISE COW that goes on this hole. 7 Place the sensor in the hole, the side with the HIKOB logo up. Place it so that the top surface of the sensor is about 5mm below the top surface of the road.