Troubleshooting Guide

if the fittings will not seal properly:
Check to see if the expander head is screwed
on tightly.
-
Tighten the head.
Check to see if the exapnder head segments are bent
or misaligned.
-
Replace the expander head.
Are the expander head segments not properly
contracting between expansions?
Clean and relubricate the expander head.
-
-
Check to see if the expander cone is
properly lubricated.
-
Clean and relubricate the expander cone.
has the fitting been damaged?
-
Replace the fitting.
Was the PEX tubing removed while the expander
cone was in the expanded postion?
Cut 2" (50 mm) from the PEX tubing and restart
-
the process.
is the PEX tubing and Ring dry?
-
Wipe dry with a clean, lint-free cloth.
is there grease from the expander head inside the
PEX tubing?
-
Wipe off all grease from inside the PEX tubing and
relubricate the expander head.
The Ring slides during the expansion process:
is the PEX tubing and Ring dry?
-
Wipe dry with a clean, lint-free cloth
Are your hands clean and dry?
-
Make sure your hands are clean and dry. Oils from
your hands can lubricate the PEX tubing and Ring.
is the Ring being held properly in place?
-
Use your thumb to hold the ring in place for the first
couple of exapansions.