Download Print this page

SCI 4000 Series Quick Start Manual

4-in-1 multi-function testers

Advertisement

Quick Links

4000 Series
4-in-1 MULTI-FUNCTION TESTERS
M odels: 4320, 4 52 0
SAFETY CHECKLIST
Survey the test station. Make sure it is safe & orderly.
Always keep unqualifi ed/unauthorized personnel away from the test area.
Familiarize yourself with safety protocols in the event of a problem.
Exercise caution and never touch products or connections during a test.
Train operators. Connect the return lead fi rst and never touch clips directly.
You should always know when a test is being performed.
WARNING:
ELECTRICAL SAFETY TESTING. AN ELECTRICAL SAFETY TESTER PRODUCES VOLTAGES AND
CURRENTS THAT CAN CAUSE HARMFUL OR FATAL ELECTRIC SHOCK. TO PREVENT ACCIDENTAL
INJURY OR DEATH, THESE SAFETY PROCEDURES MUST BE STRICTLY OBSERVED WHEN HANDLING
AND USING A TEST INSTRUMENT.
QUICK START GUIDE
THIS GUIDE WAS CREATED FOR OPERATORS HAVING SOME FAMILIARITY WITH
HIPOT.COM

Advertisement

loading

Summary of Contents for SCI 4000 Series

  • Page 1 QUICK START GUIDE 4000 Series 4-in-1 MULTI-FUNCTION TESTERS M odels: 4320, 4 52 0 SAFETY CHECKLIST Survey the test station. Make sure it is safe & orderly. Always keep unqualifi ed/unauthorized personnel away from the test area. Familiarize yourself with safety protocols in the event of a problem.
  • Page 2 4320 4520 4520 Turn the power switch ON. Upon power up, you will see the SCI company name, model number, and the current software version briefl y appear on the display. After this, you will see the default test parameters.
  • Page 3: Set System Parameters

    If you wish to have multiple test setups, you will need to begin by choosing a Memory return to the Perform Test screen. Location for each test. The 4000 Series has 6 memory locations available, each of which contains 6 steps.
  • Page 4 Edit Test Parameters Press the SET key a third Press the SET key from Press the SET key again to EDITING TEST PARAMETERS EDITING TEST PARAMETERS EDITING TEST PARAMETERS time until the test types the Perform Test screen confirm the memory step EDITING TEST PARAMETERS EDITING TEST PARAMETERS appear.
  • Page 5: Conducting A Test

    Conducting a Test WARNING: DO NOT TOUCH THE DEVICE UNDER TEST ONCE YOU START THE TEST. Adapter Box Connections To increase operator safety, you may elect to use an adapter box for products terminating in either a two-prong or three-prong line cord. If using an adapter box, follow these instructions to safely connect a DUT.
  • Page 6 Conducting a Test WARNING: DO NOT TOUCH THE DEVICE UNDER TEST ONCE YOU START THE TEST. DUT Connection If you elect to use test leads, follow these instructions to safely connect a DUT. Hook the black return lead (P/N 99-10238-01) into the RETURN terminal located on the front panel.
  • Page 7 Conduct A Test WARNING: DO NOT TOUCH THE DEVICE UNDER TEST ONCE YOU START THE TEST. Connect the Interlock Disable Key (P/N 99-10040-01) to the Signal Input connector on the rear panel of the tester. If you’re not utilizing a DUT enclosure (P/N 99-10715-01) or other safety device, the Interlock Disable Key is required in order to run a test.
  • Page 8 Testers For Electrical Safety Compliance 28105 N. Keith Drive, Lake Forest, IL 60045 USA +1-847-932-3662 • +1-800-504-0055 • Fax +1-847-932-3665 • hipot.com • info@hipot.com © 2019 SCI SAFETY MADE SIMPLE® V1.1 1/19...

This manual is also suitable for: