Page 1
For models T../MA-BTB, T../MA-BTBC T../MA-ANJ INSTALLER’S MANUAL THIS MANUAL IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE. IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION SERVICE APPARENT PRODUCT...
Page 2
TABLE OF CONTENTS Preinstallation Instructions for Dealer Specifications Cycle Sequence Settings Softener System Setup (programming) Bypass Valve Description & Diagrams Installation Installer Settings Hardness, Override, Regen Time & Time of Day Normal Operating & Error Displays, Power Loss Low Salt Warning & Resetting It Start Up Instructions Replacement Parts &...
CONTROL VALVE SPECIFICATIONS SERVICE FLOW RATE & PRESSURE LOSS 27 gpm (102.2 lpm) @ 15 psi (103 kPa) (valve only, including bypass valve, but ΔP not including mineral, etc.) BACKWASH FLOW RATE & PRESSURE LOSS 27 gpm (102.2 lpm) @ 25 psi (103 kPa) (whole conditioner, including bypass ΔP valve)
Page 4
The following is an example of how to set a valve so that when regeneration is initiated BACKWASH occurs first, BRINE occurs second, RINSE occurs third, and FILL occurs fourth. Step 1CS – Press NEXT and DOWN simultaneously for 3 seconds and release. Then press NEXT and DOWN simultaneously for 3 seconds and release.
Page 5
Step 1S – Press NEXT and DOWN simultaneously for 3 seconds and release. Step 2S – Choose SOFTENING using UP or DOWN. Press NEXT to go to Step 3S. Press REGEN to exit Softener System Setup. Step 3S – Select the time for the first cycle (which in this example is BACKWASH) using UP or DOWN.
Page 6
Step 9S – Set Regeneration Time Options using UP or DOWN. If value is set to: “DELAYED REGEN” means regeneration will occur at the preset time; “IMMEDIATE” means regeneration will occur immediately when the volume capacity reaches 0 (zero); or ...
BYPASS VALVE The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1" full flow bypass valve incorporates four positions including a diagnostic position that allows a service technician to have p r ess ur e to test a system while providing untreated bypass water to the building.
Page 8
INSTALLATION GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments but are not designed to support the weight of a system or the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
Page 9
special attention to codes for air gaps and anti-siphon devices. IMPORTANT: Never insert a drain line directly into a drain, sewer line, or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the conditioner.
Page 10
Step 5I – Next Regeneration Time (minutes): Set the minutes of day for regeneration using DOWN or UP. This display will not be shown if “IMMEDIATE” is selected in Set Regeneration Time Option in Softener System Setup Step 9S. Press NEXT to go to Step 6I.
Page 11
NORMAL OPERATING DISPLAYS When the system is operating, several displays may be shown. Pressing NEXT will alternate between the displays. One of the displays is the current time of day. CAPACITY REMAINING is the gallons that will be treated before the system goes through a regeneration cycle. Pressing DOWN while in the Capacity Remaining display will decrease the capacity remaining in 10 gallon increments.
Once the salt remaining has gone below the set point, the display will automatically shows “SALT LEVEL IS LOW” on the screen and a word “ALERT” flashes. RESETTING THE SALT AMOUNT AFTER ADDING Step 1 – Press the NEXT button until SALT LEVEL appears in the display. Step 2 –...
SERVICE INSTRUCTIONS DRIVE ASSEMBLY Remove the valve cover to access the drive assembly by pulling out slightly on the two tabs centered on the side. Disconnect the power source plug (black wire) from the PC board prior to disconnecting the motor or water meter plugs from the PC board.
Page 20
and establishes the service piston position. The display should flash all wording, then flash the software version and the cycle number, (e.g. 164) and then reset the valve to the service position. DRIVE CAP ASSEMBLY, MAIN PISTON AND REGENERANT PISTON The drive assembly must be removed to access the drive cap assembly.
Page 21
Reattach the drive cap assembly and piston(s) and the drive assembly. After completing any valve maintenance, press and hold NEXT and REGEN buttons for 3 seconds or momentarily unplug power source jack (black wire). This resets the electronics and establishes the service piston position.
Page 22
BYPASS VALVE The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve caps. Before working on the rotors, be sure that there is a closed shut-off valve ahead of the unit and the system is depressurized.
Page 23
TROUBLESHOOTING PROCEDURES Problem Cause Solution a. Transformer unplugged a. Reconnect transformer b. Repair or use working b. No power to outlet outlet 1. Timer does not display time of day c. Defective transformer c. Replace transformer d. Defective PC board d.
Page 24
Waterite Technologies, Inc. 3-75 Meridian Drive Winnipeg, Manitoba Canada R2R 2V9 (204) 786-1604 (204) 783-1599 fax www.waterite.com...