Not enough water inside the
tank
Mist level is set too low
Preset humidity is set too low
LED display is on, no mist or
little mist is produced
The base might be over lled
Mineral buildup on atomizer
Tank may be damaged
Tank cap is not tightened
securely
2
Rubber ring was not
Tank leakage
installed on tank cap
1
Spring stuck
Mist level is set too high for
the room size
Mist height is low, damping
surrounding desk or oor.
Condensation forms around
humidi er or on windows
and walls
Air inlet is blocked
Low indoor temperature
leads to liquefaction
15
Re ll and reinstall the water
tank
Adjust to maximum mist
Check if current humidity is
higher than preset humidity,
reset humidity to a higher
level
Remove the tank, empty
the base & replace the
lled tank on the empty
base
Feel if air comes out from
the the nozzle, if yes, then
clean water scale on the
atomizer as instructed
Check for possible cracks in
the tank, replace if
necessary
Tighten the tank cap
Check the tank cap for
rubber ring, rubber cap
and spring, contact us if
any is missing
Ensure the
1
spring is
secured properly to the
tank allowing water to pass
through to the base
1. Check if the room is too
humid, adjust to lower
mist, 40%-60% works best
2. Open door and windows,
or change to a larger
room
Humidi er should be
placed on a hard at
surface, 2 feet above the
oor, 12 inches away from
the wall. Point Mist Outlet
away from wall or window
Raise the room temperature
to 25°C/77°F
Mist level is set too low for the
room size
Air inlet is blocked
Poor humidi cation
Low indoor temperature
leads to liquefaction
White Dust Appears / Black
Tap water may contain too
coating in the base akes off
much minerals
Strange Odor
Unit needs to be cleaned
Water is going down to the
Strange water noise
water reservoir
Humidi er is getting too hot
Unit works for too long
1-1. Adjust to maximum mist
1-2. Close door or windows to
reduce air ventilation, or
change to a smaller room
Humidi er should be
placed on a hard at
surface, 2 feet above the
oor, 12 inches away from
the wall
Raise the room temperature
to 25°C/77°F
Replace with ltered or
distilled water or use with a
TaoTronics Demineralization
Cartridge
Clean the humidi er as
instructed
Leave the empty water tank
open in a cool place for 12
hours without the water
tank cap attached
This is normal while it is
working
Power off and place in a
well-ventilated place for 10
minutes
16