Contemporary Controls BASRT-B Installation Manual

Bacnet/ip to ms/tp router

Advertisement

BASRT-B
BACnet/IP to MS/TP Router
Installation Guide
TD071200-0IC
For Firmware Versions 1.x

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BASRT-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Contemporary Controls BASRT-B

  • Page 1 BASRT-B BACnet/IP to MS/TP Router Installation Guide TD071200-0IC For Firmware Versions 1.x...
  • Page 2 Trademarks Contemporary Controls, ARC Control, ARC DETECT, EXTEND- A-BUS, RapidRing, and CTRLink are trademarks or registered trademarks of Contemporary Control Systems, Inc. Specifications are subject to change without notice. Other product names may be trademarks or registered trademarks of their respective companies.
  • Page 3: Table Of Contents

    Contents Introduction ..............4 Specifications ............... 5 Electrical ..............5 Environmental .............. 5 Mounting ..............5 Functional ..............5 Electromagnetic Compatibility ........5 Connectors ..............6 EIA-485 Bias and Termination Jumpers ....... 6 Mechanical ..............6 Power................7 POWER SUPPLY PRECAUTIONS ......7 Limited Power Sources ..........
  • Page 4: Introduction

    MS/TP devices. The router is configurable via its internal webpage. The BASRT-B comes in a metal case, is DIN-rail mounted and is powered from a 24 VAC/VDC source. It has one isolated MS/TP port and one 10/100 Mbps Ethernet Auto-MDIX port.
  • Page 5: Specifications

    Specifications Electrical INPUT Voltage (±10%) 24 V 24 V Current (maximum) 125 mA Power: 3 VA Frequency: 47–63 Hz (Class 2 Circuits Only) Environmental Operating temperature: 0°C to 60°C –40°C to +85°C Storage temperature: Relative humidity: 10–95%, non-condensing Mounting TS-35 DIN-rail Functional Ethernet MS/TP...
  • Page 6: Connectors

    Connectors 3-pin (MS/TP) Pin Assignments (Also explained on product label) Figure 1 — 3-pin Connector RJ-45 (MDI Ethernet) Pin Assignments TD + RD + TD – RD – (All other pins are unused.) Figure 2 — RJ-45 Connector USB Mini B Connector (Aux) This connector is only used for firmware upgrades.
  • Page 7: Power

    Power The BASRT-B requires 24 VAC or 24 VDC (see Figure 6) while drawing no more than 3 W of power. The recommended conductor size is 16–18 AWG. COM is directly connected to zero volts and the chassis is DC isolated from zero volts. Input connections are reverse-polarity protected.
  • Page 8 For MS/TP devices that share a power source with the BASRT-B, see Figure 7 for proper 2-wire bus connections and Figure 8 for proper 3-wire bus connections.
  • Page 9 Figure 8 — 3-wire MS/TP Bus with Shared Power Source For MS/TP devices that use a power source separate from the BASRT-B, see Figure 9 for proper 2-wire bus connections and Figure 10 for proper 3-wire bus connections. Figure 9 — 2-wire MS/TP Bus with Separate Power Sources...
  • Page 10: Limited Power Sources

    Figure 10 — 3-wire MS/TP Bus with Separate Power Sources Limited Power Sources The router should be powered by a limited power source complying with the requirements of the National Electric Code (NEC) article 725 or other international codes meeting the same intent of limiting the amount of power of the source.
  • Page 11: Operation

    Operation MS/TP Port The MS/TP port uses an isolated EIA-485 transceiver that is connected to a 3-pin removable connector (Figure 1). The EIA- 485 transceiver’s + and – lines tie to + and – pins of the connector. The SC pin ties to the circuit ground of the EIA-485 transceiver.
  • Page 12: Ethernet Port

    D, and 130 ohms of termination impedance for the T jumper. With all three jumpers installed, the effective termination resistance is 120 Ω — consistent with the BACnet standard. If the BASRT-B is not installed at the end of a segment, remove all the jumpers and install 120 Ω...
  • Page 13: Webpage Configuration

    Class C subnet mask of 255.255.255.0 (/24). Figure 12 shows the setup for accessing the MS/TP network using BASRT-B, a computer for configuration, and a connection to the MS/TP network. To configure the router, attach it to a computer with an Ethernet connection and a standard web browser.
  • Page 14 On some systems, this option is: ―My Network Places‖. Figure 13 — Steps for Changing the IP Address of the PC Used for Setup TD071200-0IC...
  • Page 15 After entering the router’s IP address into your browser’s address field, you will see the Router Configuration Page with the default values as shown in Figure 14 — using Windows Internet Explorer. Figure 14 — Router Configuration Page with Default Values Each configuration parameter is explained on the following pages.
  • Page 16: Device Parameter

    The BACnet/IP network number is a 16-bit value (1–65534). Each network within the BACnet internetwork must have a unique number. This includes the BACnet/IP and MS/TP sides of the BASRT-B. Do not use addresses 0 or 65535 since these addresses are reserved. IP Address (Default Value = 192.168.92.68)
  • Page 17: Ms/Tp Parameters

    1. equals the highest MAC address of any master, and 2. all masters use sequential MAC addresses starting with 1 Since many BACnet devices do not allow this parameter to be changed, leave the BASRT-B at the default value. Max Info Frames (Default Value = 40) This is the maximum number of messages that can be routed onto the MS/TP network by the router per token pass.
  • Page 18 those passed by the router from BACnet/IP. The default value usually provides good performance. MS/TP Baud Rate (Default Value = 38400) The baud rate of the MS/TP network can be 9600, 19200, 38400 or 76800 bps. All MS/TP devices on the same MS/TP network must use the same baud rate.
  • Page 19: Warranty

    Warranty Contemporary Controls (CC) warrants this product to the original purchaser for two years from the product shipping date. Product returned to CC for repair is warranted for one year from the date the repaired product is shipped back to the purchaser or for the remainder of the original warranty period, whichever is longer.
  • Page 20: Declaration Of Conformity

    Equipment — Immunity Characteristics — Limits and Methods of Measurement Manufacturer: Authorized Representative: Contemporary Control Systems, Inc. Contemporary Controls Ltd 2431 Curtiss Street Sovereign Court Two, UWSP Downers Grove, IL 60515 USA Sir William Lyons Road Coventry CV4 7EZ UK...