FAULT CODE:
DRAINAGE:
During the dry mode, you will need a garden hose (sold
separately) to drain the condensate from the unit.
Remove the rubber stopper from the hose connector, then screw on a
garden hose to the connector as shown on Fig. 23.
The hose may then:
A. Discharge into a drain that is lower than the unit.
B. Be connected to a condensate pump (sold separately).
C. During cooling mode, please replace the rubber stopper
to the hose connector to reach the maximum performance.
2009 Electrolux Home Products, Inc.
If the display reads "AS" , the room temperature sensor has failed. Contact your Authorized
Frigidaire Service Center.
If the display reads "ES" , the evaporator temperature sensor has failed. Contact your
Authorized Frigidaire Service Center.
If the display reads "E4" , the display panel communication has failed. Contact your
Authorized Frigidaire Service Center.
If the display reads "P1" , bottom tray is full. Carefully move the unit to a drain location, remove
the bottom drain plug and let the water drain away. Restart the machine until the "P1" symbol
disappears. If error repeats, call for service.
If the display reads "E7", the indoor motor has failed. Contact your Authorized Frigidaire
Service Center.