Page 1
Automatic X-ray Film Processor Installation, Operation And Maintenance Manual WARNING: Do not plug into the electrical mains power supply before reading this manual – or before filling the machine with liquids...
Page 3
Contained in this manual is information on the right place to position the Sprint, how to set up the machine correctly for use, and how it should be maintained so that you receive consistently high quality results over a long working lifetime.
TECHNICAL DESCRIPTION SITING THE SPRINT EXTERNAL FEATURES OF THE MACHINE INTERNAL FEATURES OF THE MACHINE WALL MOUNTING DIAGRAM WALL MOUNTING INSTRUCTIONS PREPARING TO USE THE SPRINT Filling the Machine with Chemicals OPERATING THE SPRINT To Start Processing Film Film Collection...
POSITION THE MACHINE TO ALLOW EASY DISCONNECTION FROM ELECTRICAL SUPPLY. Input rating: 110-120V, 200-240V ~ 50/60 Hz – Power Input 200w This equipment must be plugged into an earthed/grounded socket outlet. Use only the connection lead supplied. _______________________________________________________________________ 20/08/2007 SPRINT MkV...
TECHNICAL DESCRIPTION --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The Velopex "Sprint" X-Ray Processor is a machine for developing and fixing dental x-ray films without user contact between insertion of the exposed film and receipt of the developed film into the wash-tank for collection at the end of the process.
SITING THE SPRINT --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- PRE-INSTALLATION INSTRUCTIONS Although the Velopex Sprint is designed for use in daylight, care should be taken to avoid sources of intense light. For example do not site directly under a window, fluorescent tube or floodlight. A well ventilated position is mandatory.
Page 9
EXTERNAL FEATURES --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- _______________________________________________________________________ 20/08/2007 SPRINT MkV...
Page 10
INTERNAL FEATURES --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- _______________________________________________________________________ 20/08/2007 SPRINT MkV...
WALL MOUNTING INSTRUCTIONS --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The Sprint is ideal for wall mounting and is fitted with 4 keyhole slots on the rear panel. A further 2 locking holes at the bottom of the rear panel prevent accidental lifting once in place.
PREPARING TO USE THE SPRINT --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The machine is supplied in a single carton containing:- Velopex SPRINT Processor; Operator's Manual; Water tank; Machine Accessory bag containing: - Electric Lead; Transport Module Turning Tool; Cleaning Brush; Chemical Change Chart and Warranty Card.
The wash tank (item 5) should now be filled with water to the "level" line and hung in position on the left hand side of the main case, at the film exit slot. OPERATING THE SPRINT --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- TO START NOTE: - Ensure that the two tanks are correctly filled with chemicals and fitted into position before switching on the machine.
4. At the end of the day turn the Mains Power Switch OFF and disconnect machine. WARNING: Turning off electrically at the end of each workday is an essential safety procedure. POSITION THE MACHINE TO ALLOW EASY DISCONNECTION FROM ELECTRICAL SUPPLY. _______________________________________________________________________ 20/08/2007 SPRINT MkV...
FILM STORE --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The SPRINT is fitted with a simple film store and dispenser drawer for standard intra-oral film (item 9). To load the film store, unclip the top from the front cover and remove. Stack new film neatly into the back of the film store (item11) as illustrated, uniformly orienting in one direction.
Always observe the chemical manufacturer's recommendation for this situation. Problems of this nature can be avoided by wearing protective glasses and gloves. _______________________________________________________________________ 20/08/2007 SPRINT MkV...
3. Check that transport modules have been put through the correct cleaning procedure. 4. Should there be any damage to the belts, such as tearing or twisting, order a replacement module. _______________________________________________________________________ 20/08/2007 SPRINT MkV...
3. Check that there has been no chemical mix-up, leading to cross- contamination. 4. Check temperature of developer and fixer tanks. This is generally set at 27°C (81 °F). A substantial difference could lead to dark film. Switch off the machine and call for service. _______________________________________________________________________ 20/08/2007 SPRINT MkV...
4. Check modules for correct positioning. When found in incorrect order, contamination will have occurred. Thoroughly wash and replace with fresh chemicals. 5. Check for stray light entering machine - proceed as for fogging (see above). _______________________________________________________________________ 20/08/2007 SPRINT MkV...
WARNING: If the unit should emit abnormal odour, become overheated in some parts or produce unusual noises, unplug from Main Power Supply. Contact your Velopex supplier. A clean, well-maintained machine will produce good clear x-rays; a dirty machine will cause problems.
Medivance Instruments as repairable. Application should be made to: Medivance Instruments Limited Service Department Barretts Green Road, Harlesden London NW10 7AP Tel: - +44 (0)20 8965 2913 Fax: - +44 (0)20 8963 1270 _______________________________________________________________________ 20/08/2007 SPRINT MkV...
Page 25
Medivance – Sprint MkIV Operating Manual– Issue 4 08/08/07 Velopex is a trademark of Medivance Instruments Ltd...