Download Print this page

Holars H-KOD 12/24 User Manual

Waterproof dual-relay access control

Advertisement

Quick Links

Waterproof
Dual-relay Access Control
H-KOD 12/24
User Manual
INTRODUCTION

Advertisement

loading
Need help?

Need help?

Do you have a question about the H-KOD 12/24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Holars H-KOD 12/24

  • Page 1 Waterproof Dual-relay Access Control H-KOD 12/24 User Manual INTRODUCTION...
  • Page 2 It is designed and manufactured to perform in a wide range of indoor, outdoor, and harsh environments. The H-KOD 12/24 supports up to 1100 users in multiple access configurations (Card, PIN, or Card + PIN). The built in card reader supports EM 125KHz frequency cards.
  • Page 3: Installation

    Surface Finish Powder Coat Dimensions L120xW76xH25 (mm) (H-KOD 12/24) L130xW56xH23 (mm) (SK4) Unit Weight 600g (H-KOD 12/24) / 500g (SK4) Shipping Weight 700g (H-KOD 12/24) / 650g (SK4) Carton Inventory H-KOD 12/24 Access Control Diode IN4004 (For relay circuit protection)
  • Page 4 Wiring Wire Insulation Colour Function Notes Basic Standalone Wiring AC&DC 12-28V AC/DC AC Regulated Power Input Black AC&DC 12-28V AC/DC AC Regulated Power Input Grey& Black Negative Pole Blue NO 1 Normally Open Relay 1 output White COM 1 Common Connection for Relay 1 output Green NC 1 Normally closed Relay 1 Output...
  • Page 5: Function Description

    Master Card H-KOD 12/24 master can use master cards to program user cards into and out of the system. There are two pre-programmed master cards (an Add Card, and a Delete Card) to allow rapid card enrollment. It is...
  • Page 6: User Settings

    # key, in order to be granted access. • Card + PIN: The User must first present a valid Card to the H-KOD 12/24 and then enter their PIN code followed by the # key, in order to be granted access.
  • Page 7 Note that to undertake the following programming, the master user must be logged in Note: When adding users, if the Card or Pin user has been enrolled already, you can not add it again on the same zone, or the device will give a bleep as error. But it is ok to enroll the same card or Pin for the both zones.
  • Page 8 This option can be used when a user has lost their card. To delete card users by card number Input 8 digits or 10 digits Card number Cards can be deleted continuously without exiting from programming mode. To set users for Zone 2. ( 4 To set Pin user for Zone 2 is the same as Zone 1, only the ID number is 1001-1100 for Zone 2.
  • Page 9 Relay Setting (Pulse mode, Toggle mode) Pulse mode (Factory default) For Zone 1: 5 1~99 For Zone 2: 5 1~99 The door relay time is between 1~99 seconds, the factory default setting is 5 seconds. 1 means Zone 1. 2 means Zone 2.
  • Page 10 Reset to Factory Default: This will reset the H-KOD 12/24 to the factory default but all card/PIN information will still be retained. This will also require reprogramming of the Master Add and Delete Cards. NOTE: This is useful if the original Master Add and Delete Cards have been lost.
  • Page 11 Entry Granted for Zone 1 Short Single Beep Entry Granted for Zone 2 Alarm Mode Engaged Flashing Alarm H-KOD 12/24- Simplified Instruction Function Description Operation Enter the Programming Mode * (Master Code) # (666666 is the default factory master code) 0 (New Master Code)...
  • Page 12 How to be granted access Card User Read card PIN User Enter (PIN) #...