Popp POPE004001 Quick Start

Secure z-wave smoke sensor plus siren

Advertisement

Quick Links

Popp
Secure Z-Wave Smoke Sensor plus Siren
SKU: POPE004001
Quickstart
This is a secure Z-Wave Device for Europe. To run this device please insert fresh 1 * 9V Block batteries. Please make sure the internal battery is
fully charged.
Pressing the button (3) for one second includes and excludes the device. The smoke sensor is powered either by an internal battery or an optional
external integrated power supply. It supports secure communication and will, without further configuration, notify other smoke sensors and sirens
of the same type when an alarm occurs.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart
section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-way communication)
and every mains powered node can act as a repeater for other nodes (meshed network) in case the
receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-
Wave device regardless of brand and origin as long as both are suited for the same frequency
range.
If a device supports secure communication it will communicate with other devices secure as long as
this device provides the same or a higher level of security. Otherwise it will automatically turn into a
lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

This product combines a certified stand-alone smoke detector with an insertable Z-Wave module. The smoke detector is certified by the VdS and DIN EN
14604 and satisfies all legal requirements. The smokebox is made of steel and antistatic plastic.
A button on the device can be used to test the smokebox, the electronics and the battery. In addition the device has an integrated test functionality to make
manual tests with Aerosol unnecessary. The battery warning gets send for at least 30 days. During this time the smoke sensor stays fully functional.
The Z-Wave radio module enables the device to send smoke-alarms to the connected central Z-Wave controller. The smoke sensor can also be used as Z-
Wave siren; for that the Z-Wave controller sends an on or off command to the siren. The radio module uses either the smoke sensors integrated 9V battery
or can be powered by an external 12V power supply.
According to the VdS 3515 (smoke sensors with radio communication) this device will relay all alarms to all other smoke sensors (004001) in the Z-Wave
network to create a house-wide alarm. This connection of the smoke sensors is fully automatical and needs no further configuration. The smoke sensors
and the controller communicate via an secure protocol to prevent manipulation.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You
can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is
recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is
inoperable.
Press the button on the bottom of the device for at least 10 seconds

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POPE004001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Popp POPE004001

  • Page 1: Product Description

    Popp Secure Z-Wave Smoke Sensor plus Siren SKU: POPE004001 Quickstart This is a secure Z-Wave Device for Europe. To run this device please insert fresh 1 * 9V Block batteries. Please make sure the internal battery is fully charged. Pressing the button (3) for one second includes and excludes the device. The smoke sensor is powered either by an internal battery or an optional external integrated power supply.
  • Page 2: Installation

    Safety Warning for Batteries The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands. Installation Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.
  • Page 3: Node Information Frame

    Note: All communication of the wireless module is performed with application level security if the device was included securely and all communication partners support secure communication as well. In case a non-secure device is associated for switching on smoke alarm, the smoke detector will detect this and change its communication styla with this very device to non-secure.
  • Page 4: Technical Data

    Setting Description 03 - 127 seconds Parameter 3: Value of BASIC Set On-Command Size: 1 Byte, Default Value: 99 Setting Description 00 - 99 Command Value Parameter 4: Value of BASIC Set Off-Command Size: 1 Byte, Default Value: 0 Setting Description 00 - 99 Command Value...
  • Page 5: Controlled Command Classes

    Manufacturer Specific Powerlevel Firmware Update Md Battery Association Version Security Controlled Command Classes Basic Explanation of Z-Wave specific terms Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers. Slave —...

Table of Contents