User's Manual for the wGT3X+ and
wActiSleep+
P a g e
| 1
49 E. Chase St.
Pensacola, FL 32502
tel 850.332-7900
fax 850-332-7904

Advertisement

Table of Contents
loading

Summary of Contents for ActiGraph wGT3X+

  • Page 1 www.theactigraph.com User’s Manual for the wGT3X+ and wActiSleep+ P a g e 49 E. Chase St. Pensacola, FL 32502 tel 850.332-7900 fax 850-332-7904...
  • Page 2 www.theactigraph.com Change Page About the The following table describes the changes that have been made to this document change page since its original baseline. This table shall be maintained as long as this document is table active. Date of Revision Brief Description of Change Approval Initial version...
  • Page 3: Table Of Contents

    www.theactigraph.com Table of Contents Important Information and Symbols ......................4 Introduction ..............................7 Specifications and Functionality of the wGT3X+ and wActiSleep+ ............... 7 Data ................................7 Acceleration ............................7 Ambient Light ............................7 Steps ..............................8 Inclinometer ............................8 Low Frequency Extension ........................9 Data Collection ............................
  • Page 4: Important Information And Symbols

    Changes or modifications not expressly approved by ActiGraph, LLC will void the user's authority to operate the equipment under FCC regulations. A patient vicinity is areas in which PATIENTS are normally cared for and the space with surfaces likely to be contacted by the PATIENT or an attendant who can touch the PATIENT.
  • Page 5 www.theactigraph.com These devices are classified as Class I medical devices within the European Union and have been approved to be sold as medical devices according to the European Union's regulatory requirements listed below:  EN 60601-1: 1988 + A1: 1991 + A2: 1995 – Medical Electrical Equipment Part 1: General Requirements for Safety ...
  • Page 6 The wGT3X+ and wActiSleep+ are water resistant in accordance with IEC 60529 and have the International Protection Rating: IPX7, or immersion in one (1) meter of water for up to 30 minutes. Contact ActiGraph Customer Service regarding the disposal of these products. P a g e 49 E. Chase St.
  • Page 7: Introduction

    www.theactigraph.com Introduction The wGT3X+ and wActiSleep+ activity monitors provide objective measurements of human activity and are used in many research and clinical applications. They include a microelectromechanical system (MEMS) based accelerometer and an ambient light as data sensors. Specifications and Functionality of the wGT3X+ and wActiSleep+ Data The devices include both an acceleration sensor as well as an ambient light sensor.
  • Page 8: Steps

    www.theactigraph.com Sunrise/sunset 1,000 Overcast day 10,000-25,000 Full daylight 32,000-130,000 Direct sunlight Table 1 – Lux Level Interpretation Estimates Steps Step counts are accumulated on a per-epoch basis and are based on accelerometer data collected on the vertical axis. An algorithm present in the device firmware filters out the accelerometer’s baseline noise level to help accurately accumulate the steps-per-epoch.
  • Page 9: Low Frequency Extension

    3-axis data during *.gt3x file decompression. Unlike previous ActiGraph products, the wGT3X+ and wActiSleep+ do not filter or accumulate data into epochs. Raw data is collected at the selected sample rate and is post-processed in the ActiLife. Because these devices collect data from all sensors at all times, users can generate native ActiLife *.agd files...
  • Page 10: Water Resistance

    Initialization Both the wGT3X+ and the wActiSleep+ can now be fully initialized wirelessly. This can be performed with a PC utilizing a USB ANT dongle or with ActiGraph’s new ActiLife Mobile available on the iPhone platform. Device Status Device specific status information can be obtained.
  • Page 11: Battery

    Battery All ActiGraph devices use a lithium ion rechargeable battery that has a maximum voltage of approximately 4.20 volts. At 3.1 volts the devices enter a low voltage mode state (HALT mode).
  • Page 12 www.theactigraph.com wGT3X+ and wActiSleep+ Battery Life Memory Limit Sample Rate (Hz) (Days) (Days) 31.00 42.50 27.50 32.00 24.50 25.00 22.50 21.00 20.50 18.00 19.00 16.00 17.50 14.00 16.50 12.50 Table 5 – Battery life based on 16 Hrs Active, 8 Hrs sleep. wGT3X+ and wActiSleep+ Sample Rate (Hz) Battery Life...
  • Page 13: Low Voltage Mode (Halt)

    Low Voltage Mode (HALT) ActiGraph devices enter a “Low Voltage Mode” (or HALT) state when the battery discharges beyond a point of being able to power the device. In this mode, all important variables and data are stored in flash memory to secure the device download.
  • Page 14 www.theactigraph.com Device Connected to PC Red LED (Fault Indicator) 2 Flashes Li-Ion Battery is Faulty 3 Flashes A hardware failure occurred while recording data. Contact customer support at support@theactigraph.com Green LED 1 Flash Battery Charging Multiple Flashes Communicating with PC via USB Steady On Battery Fully Charged Device Not Connected to PC...
  • Page 15: Wearing The Device

    Note: It is not safe to wear devices while they are charging. It is recommended that children under 12 years of age wear ActiGraph devices on the elastic belt (versus the adhesive belt clip) as it is the most secure way to wear the device. Belt loop pouches, wrist and ankle straps are also available.