Eelectron IC00P01DAL Operating Instructions Manual

Knx-dali gateway

Advertisement

Quick Links

IC00P01DAL - DALI gateway
DALI gateway
Operating instructions

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The DALI control voltage is a functional extra-low voltage (FELV). On installing, ensure
safe isolation between KNX and DALI.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1
(1) Button field for manual operation
(2) Programming button and LEDs
(3) KNX connection
(4) Display of DALI devices or DALI group
(5) Connection for mains supply
(6) DALI output
3 Function
System information
This device is a product of the KNX system and complies with the KNX directives. Detailed
technical knowledge obtained in KNX training courses is a prerequisite to proper understanding.
The function of this device depends upon the software. Detailed information on loadable
software and attainable functionality as well as the software itself can be obtained from the
manufacturer´s product database.
1/9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IC00P01DAL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eelectron IC00P01DAL

  • Page 1: Safety Instructions

    IC00P01DAL - DALI gateway DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load.
  • Page 2 IC00P01DAL - DALI gateway Planning, installation and commissioning of the device are carried out with the aid of KNX- certified software. Full functionality with KNX commissioning software version ETS3.0f onwards. An updated version of the product database, technical descriptions and conversion programs and other auxiliary programs are available on our Internet website.
  • Page 3: Operation

    IC00P01DAL - DALI gateway 4 Operation Operating elements Figure 2 (4) Display of DALI number (1...64) (4a) DALI group (4b) Individual DALI devices (7) Button c – Manual operation (8) LED c – On: Continuous manual mode active (9) ON/nbutton – switch on or increase brightness (10) LED ON/n –...
  • Page 4 IC00P01DAL - DALI gateway i After 5 seconds without a button-press, the device returns automatically to bus operation. Switching off temporary manual operation The device is in short-term manual mode. No button-press for 5 seconds. - or - Press c button briefly as many time as necessary until the device leaves the short-time manual mode.
  • Page 5 IC00P01DAL - DALI gateway Unblocking a DALI device or group The device is in continuous manual mode. Press c button briefly as many times as necessary until the display (4) flashes the desired DALI number. Press ON/n and OFF/o buttons simultaneously for at least 5 seconds.
  • Page 6 IC00P01DAL - DALI gateway If multiple miniature circuit breakers supply dangerous voltages to the device or load, couple the miniature circuit breakers or label them with a warning, to ensure disconnection is guaranteed. Connect bus line with connecting terminal. i DALI devices can be connected to various phase conductors.
  • Page 7 IC00P01DAL - DALI gateway Figure 6: Installing the cover Route the bus line towards the rear. Install cover on top of the bus terminal so that it snaps into place (Figure 6). Removing the cover Figure 7: Removing the cover Press the cover to the side and pull it off (Figure 7).
  • Page 8: Troubleshooting

    IC00P01DAL - DALI gateway 6 Appendix 6.1 Technical data Supply Rated voltage AC 110 ... 240 V ~ Mains frequency 50 / 60 Hz Rated voltage DC DC 110 ... 240 V Power loss max. 3 W Ambient conditions Ambient temperature -5 ... +45 °C Storage/transport temperature -25 ...
  • Page 9: Warranty

    IC00P01DAL - DALI gateway i Simultaneous exchange of multiple DALI devices is only possible with commissioning software and project data. None of the DALI groups can be operated. Cause 1: All DALI groups disabled via bus or manual operation. Cancel disabling.