WARRANTY Avtech Electrosystems Ltd. warrants products of its manufacture to be free from defects in material and workmanship under conditions of normal use. If, within one year after delivery to the original owner, and after prepaid return by the original owner, this Avtech product is found to be defective, Avtech shall at its option repair or replace said defective item.
DC bias to the diode. The AVX-S3B-P3-NUFB contains a current-quadrupling transformer. When used with the AVO-9G-B-P-NUFB mainframe, the maximum obtainable current will be approximately 3.6A (see the "Amplitude Control" section for details).
ORIGINAL QUOTATION & CORRESPONDENCE (ABRIDGED) XXXXX, Thank you for the fax. We will reduce the series resistance in the AVX-S3B-P3-NUFB from 3 Ohms to 2.4 Ohms. The maximum current can then be estimated as: (12.5V - 1.6V) / (2.4 + 0.6 Ohms) = 3.6A Regards, Dr.
Page 6
> XXXXX, > > > > > > We can provide two week delivery of your AVX-S3B-P3-NUFB for a 15% > > > premium, if you get the order in today. (Time is very tight because of > > > summer holidays early in July!) >...
Page 7
> > > will be applied to the diode anode (pin 7). Pins 1-6 and 8 will be > > > grounded. It will not be possible to access the photodiode or thermistor > > > features. The series resistance inside the output module will be 3 Ohms. >...
GENERAL INFORMATION BASIC TEST ARRANGEMENT To fully test the AVX-S3B-P3-NUFB, and for normal operation, the output module should be connected as shown below: DC CONNECTOR (CONNECT TO GROUND IF NOT USED) 4:1 CURRENT QUADRUPLING AVX-S3B-P3-NUFB TRANSFORMER OUTPUT MODULE 50Ω (INTERNAL CIRCUITRY SHOWN)
PIN 7 (LD+) DIODE PACKAGE (TOP VIEW). AVX-S3B-P3-NUFB OUTPUT MODULE, SOCKET VIEW DIP PACKAGE. An oscilloscope may be used to monitor the MI and MV outputs. A forward DC bias may be applied to the laser diode by connecting a DC potential of 0 to +10 Volts to the DC solder terminal.
MEASUREMENT ISSUES It is very difficult to accurately observe the electrical waveforms in the AVX-S3B-P3- NUFB system. The "MV" and "MI" outputs will display noticeable ringing and inaccurate rise times due to the effect of parasitic inductance and the low resistances present (R = 2.4 Ω).