FLOWMAX 30S Operating Manual

Ultrasonic flowmeter

Advertisement

Quick Links

BA 010E/FM30S/01.18
Valid starting from
Hardware V 2.0
Software V 129
®
Flowmax
Ultrasonic
Flowmeter
Operating manual
30S

Advertisement

Table of Contents
loading

Summary of Contents for FLOWMAX 30S

  • Page 1 ® Flowmax BA 010E/FM30S/01.18 Valid starting from Hardware V 2.0 Software V 129 Ultrasonic Flowmeter Operating manual...
  • Page 2: General Safety Instructions

    NOTICE! is used to lead users to helpful NOTICE! information not related to personal injury. Intended use The flowmeter Flowmax 30S may only be used for measuring the flow of • pure, homogeneous liquids. The Flowmax 30S is not intended for use in medical applications.
  • Page 3: Table Of Contents

     Flowmax Table of contents Table of contents General safety instructions ......................2 Table of contents ..........................3 List of Figures ..........................3 Planning information ........................ 4 1.1 Areas of application............................. 4 1.2 Measuring principle ............................. 4 1.3 Cleaning ..............................5 1.4 Operational safety ............................
  • Page 4: Planning Information

    Flowmax 1. Planning information 1.1 Areas of application The flowmeter Flowmax 30S is particularly suitable for the measurement of dynamic processes of liquids in a pipe. It is used in beverage dispensing systems Its performance features are characterized by the following characteristics: no moving parts and therefore no wear •...
  • Page 5: Cleaning

    2. Assembly and installation 2.1 Installation instructions An arrow is printed on the nameplate on the front of the Flowmax 30S. The measuring instrument must be mounted so that the product flows through it in the direction of the arrow. For fastest possible gas detection it is important to keep the pipe distance from tank to Flowmax 30S as short as possible.
  • Page 6: Assembly Of The Flowmeter

    Assembly and installation Flowmax 2.2 Assembly of the flowmeter In order to fasten the Flowmax 30S to a solid ground it has two bores with female threads M4 at the front face (for dimensions see section 5, Technical NOTICE! specifications). The housing of the DN15 version has additional bores on its backside.
  • Page 7: Commissioning

    3. Commissioning 3.1 Operation If Flowmax 30S is used as a flow meter in beverage dispensing systems, it does not require any operation on site since the following parameters are in a factory setting which ensures an optimum function. The Flowmax 30S can also be supplied with customer-specific settings.
  • Page 8: Configuration Output 1

    Choose a configuration which will neither exceed the maximum output frequency of the Flowmax 30S (10kHz) nor the maximum input frequency of the control. The pulse / pause ratio is 1:1. The pulse length is limited to 1s. Exampel: 5.0 ml/pulse...
  • Page 9: Output 2

     Flowmax Commissioning 3.2.3 Output 2 Output 2 is used as line B for RS485 operation, and the vacant state of the measuring channel can be signaled via the line For the operation of the RS485 interface, the lines A and B are required, i.e.
  • Page 10: Overview Of Default Settings

    Is the measurement pipe completely filled with fluid? • Check the back pressure in the system. • When everything has been checked, switch on power. After 30 minutes with power running the measuring device reaches the maximum accuracy. Flowmax 30S is operational! M I B...
  • Page 11: Exchange Of Flowmeter

    If the device requires a configuration change, the display and programming unit FlowCon 200i may be required (see section 6. Accessories). Repair, hazardous substances Before sending the flowmeter Flowmax 30S for repair, the following precautions must be taken: Clean all process chemicals from the device. Fully rinse the flow •...
  • Page 12: Technical Specifications

     Technical specifications Flowmax 5. Technical specifications 5.1 Dimensions and weight DN 7 and DN 10 M4, 12 deep for mounting on a wall Weight: 700g All dimensions in [mm]: DN7: A = 22 DN10: A = 23.5 DN 15...
  • Page 13: Technical Specifications

    1000 ml/s Repeatability 0.5% The measuring system Flowmax 30S meets the general EMC immunity requirements according to CE, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6. It is in conformity with the requirements of the EC directives and has the CE label.
  • Page 14: Accessories

     Accessories Flowmax 6. Accessories Flowview 2S Display and supply unit for up to 2 ultrasonic flowmeters Flowmax 30S Order code 908750 FlowCon 200i External display and programming unit for use in combination with ultrasonic flowmeters Flowmax. FlowCon 200i can be used as separated display as fixed installation for Flowmax.
  • Page 15  Flowmax Shipment M I B...
  • Page 16 MIB GmbH Messtechnik und Industrieberatung Bahnhofstr. 35 D-79206 Breisach Tel. 0049 / (0)7667 / 20 777 90 Fax 0049 / (0)7667 / 20 777 99 Mail: info@mib-gmbh.com Web: www.flowmax.de...

Table of Contents