Officine Gullo WND 040 Instructions For Installation And Use Manual

Winde dispenser for residental and professional use

Advertisement

Quick Links

WND 040
WINE DISPENSER FOR
RESIDENTIAL AND PROFESSIONAL USE
INSTRUCTIONS
for installation and use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WND 040 and is the answer not in the manual?

Questions and answers

Summary of Contents for Officine Gullo WND 040

  • Page 1 WND 040 WINE DISPENSER FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS for installation and use...
  • Page 2 • Wineemotion is not liable for performance issues or incompatibilities caused by changing the settings of the machine or operating system software, or when the machine is placed in environmental settings that differ from recommendations contained in this manual. Officine Gullo...
  • Page 3 • You can check for software updates for the dispenser by visiting Wine- emotion (www.wineemotion.com/upgrades). • This dispenser supports services and applications that may require an active data connection for its operation and updating. • Keep this manual for future reference. Officine Gullo...
  • Page 4 Chap. 1 (meaning "refer to Chapter 1 "). ► → Followed by - Indicates in which order you must select the → options or menus to perform a step. For example: → In the Control Panel , select the Calibrating Menu Officine Gullo...
  • Page 5: Table Of Contents

    8.2 Installation with encased positioning and multiple machines 8.3 Installation flush with front closure 8.4 Power supply 8.5 Pneumatic system (for dispenser with external cylinders) 8.5.1 Pneumatic system (for dispensers with internal cylinders) 8.6 Climate controlled machines Manual of Use Officine Gullo...
  • Page 6 14.1 How to interact with the display 13. Operation from the main main 13.1 Calibrating 13.2 Display setting 13.3 Wine setting 13.4 Fridge setting 14. Maintenance and cleaning 14.1 Minimum qualification of personnel 14.2 Daily maintenance 14.3 Periodic maintenance Officine Gullo...
  • Page 7 14.7 Precautions for maintenance 15. Disposal of the machine 16. Declaration of compliance 17. Machine warranty 10. Certifications held by SERIES 3 Dispensers 19. Authorized cleanind products 19.1 SaniPack MP 100 19.2 SaniKleen 512 WE Manual of Use Officine Gullo...
  • Page 8: Guidelines For Reading The Manual

    If you are unsure about the correct interpretation of the instructions, contact the manufacturer to obtain the necessary clarifications. READ THE MANUAL BEFORE YOU UNPACK THE MACHINE. KEEP THIS MANUAL WITH THE MACHINE. Officine Gullo...
  • Page 9: Machine Identification

    220 Vac 50 - 60Hz 0,6 A Designed by Wineemotion in Florence Assembled in Italy 2 x FX2,5A 220 Vac 50 - 60Hz 0,6 A power consuming 130W Fridge is climatic class N Designed by Wineemotion in Florence Assembled in Italy Manual of Use Officine Gullo...
  • Page 10 Warning: this machine is for indoor use only. - This label reminds the user that the dispenser → is to be used only indoors and away from atmospheric agents that may damage it. Motor compressor thermally protected system. QR code Serial number Officine Gullo...
  • Page 11: Service Request

    Most of the aesthetic design details can be customized with different types of materials and colours, thus giving customers the chance to customise its look to match their needs. For the current list of models and variants please visit www. wineemotion.com Manual of Use Officine Gullo...
  • Page 12: Technical Information

    • Please refer to the "Technical Data" section for more details on dimen- sions and technical specifications of the dispenser as well as for the precise installation notes and necessary prerequisites. Officine Gullo...
  • Page 13: Technical Data

    Technical data Model with external cylinders 4 Bottles Dimensions (mm) Height (H) Length (L) Depth (D) Weight (Kg) Model with internal cylinders 4 Bottles Dimensions (mm) Height (H) Length (L) Depth (D) Weight (Kg) Manual of Use Officine Gullo...
  • Page 14 200 mbar Compressed air pressure 5 - 8 bar Refrigerant used R134A Max cooling circuit pressure 10 bar Description Unit Measurement Installation environment specifications Ambient temperature °C 15÷27 Maximum relative humidity (Rhu) Bottle specifications Height 280÷355 Maximum diameter Officine Gullo...
  • Page 15: Included Accessories

    5.1 INCLUDED ACCESSORIES The distributor is supplied with the following accessories: → copy of the installation manual paper or digital → warranty and compliance certificate → suction tubes Any other accessories can be supplied in special versions. Manual of Use Officine Gullo...
  • Page 16: Safety Information

    Maximum relative humidity (Rhu) 70% Table 1: Technical data Dispen- sers Description Unit Value • The dispenser must be used according to the intended purpose only. Improper use or misuse can lead to conditions of risk and economic damage. Officine Gullo...
  • Page 17 • Do not install the regulator in critical environments at risk of explo- sion and fire, next to heat sources or rooms with the risk of food conta- mination. The regulator should not be exposed to weather or corrosive fumes. Manual of Use Officine Gullo...
  • Page 18: Environmental Effects, Safety Warnings

    • All components of the dispenser having different chemical characteristics should be disposed of separatel. Officine Gullo...
  • Page 19 Illegal disposal of WEEE materials listed in the law will be punished by local law where the crime is committed. Manual of Use Officine Gullo...
  • Page 20: Packing And Unpacking

    The package must be disposed of according to applicable laws and regulations. Keep the box in case the machine needs to be transported to another location in future. CAUTION: DURING TRANSIT, DO NOT TILT THE DISPENSER HORIZONTALLY. ENSURE IT IS KEPT UPRIGHT AS SHOWN ON THE PACKAGING. Officine Gullo...
  • Page 21 7.3 Moving and lifting The dispenser may be moved, if placed on a platform, using forklifts, (manual or automatic); or with straps, making sure these are secured carefully to ensure even weight distribution prior to lifting. Manual of Use Officine Gullo...
  • Page 22 • When you receive the checklist, refer to the "package contents" to check the box numbers and ensure everything has been delivered. If any components are damaged or missing, do not install the dispenser. ► Contact an authorized dealer to resolve the problem. Officine Gullo...
  • Page 23: Installation

    ► ► the machine. → → 900÷1000 The air intake zone marked must be clear for the proper operation of the dispenser. After use, the dispenser exhausts hot air from the top marked Manual of Use Officine Gullo...
  • Page 24 The spaces shown in the figure should not be closed because they serve for ventilation of the machine. 900÷1000 900÷1000 900÷1000 The air intake zone marked must be clear for the proper operation of the dispenser. After use, the dispenser exhausts hot air from the top marked Officine Gullo...
  • Page 25: Installation With Encased Positioning And Multiple Machines

    900 to 1000 mm. The distance B is the minimum distance for dispensing, 450mm. 900÷1000 900÷1000 900÷1000 The air intake zone marked must be clear for the proper operation of the dispenser. After use, the dispenser exhausts hot air from the top marked Manual of Use Officine Gullo...
  • Page 26: Installation Flush With Front Closure

    8.3 Installation flush with front closure FOR DISPENSERS WITH EXTERNAL CYLINDERS When you close the machine front you must create an opening on the back, at the bottom, as the air is now drawn from the bottom instead of the frontal zone. Officine Gullo ►...
  • Page 27 CAUTION: DO NOT BLOCK THE FRONT BASE OPENING; THIS LOCATION WAS DEVOTED FOR AIR INTAKE. IF YOU BLOCK THE FRONT OPENING, YOU MUST PROMIDE AN OPENING FOR REAR VENTILATION. Manual of Use Officine Gullo 900÷1000...
  • Page 28 After use, the dispenser exhausts hot air from the top marked CAUTION: DO NOT BLOCK THE FRONT BASE OPENING; THIS LOCATION WAS DEVOTED FOR AIR INTAKE. IF YOU BLOCK THE FRONT OPENING, YOU MUST PROMIDE AN OPENING FOR REAR VENTILATION. Officine Gullo...
  • Page 29: Power Supply

    ► Socket with TEST only for USA and Canada. → ► Manual of Use Officine Gullo...
  • Page 30 110V - 50 Hz 220V - 50 Hz 110V - 50 Hz 220V - 50 Hz Programming port RS 232 Fuses USA e Canada: USA e Canada: EU: F 2X1.5A fast EU: F 2X1.5A fast F 2x3A fast F 2x3A fast Officine Gullo...
  • Page 31 Manual of Use Officine Gullo...
  • Page 32: Pneumatic System (For Dispenser With External Cylinders)

    Food-grade gas ( N2) or (Ar) ( chap. 5) ► → The dispenser leaves the factory provided with 2 extension tubes to facilitate installation in the → assembly phase. To regulate the gasses to the recommended pressur see chap. 5. Officine Gullo ►...
  • Page 33: Pneumatic System (For Dispensers With Internal Cylinders)

    You can only use cylinder, issued by Wineemotion spa because the connection and inlet are proprietary. For installation and maintenance of the gas cylinders see chap. 8.11. Manual of Use Officine Gullo ►...
  • Page 34: Climate Controlled Machines

    The cylinder must be placed in a safe, well-ventilated area and also needs to be fixed to a wall by means of chain or other fastening system. For the use of the nitrogen generator please read your dedicated manual from the generator manufacturer. Officine Gullo...
  • Page 35: Compressed Air Supply

    Serial of the machine, power supply voltage and the rating of the fuses chap.2 ► - This label indicates the model name of the machine and specifies the power supply and the fuse ratings contained in the power supply. → Manual of Use Officine Gullo...
  • Page 36 If any parts are worn they should be replaced, please use only original spare parts. • Do not to change the characteristics of service and safety devices and always use original spare parts. Avoid using materials not authorized by the manufacturer. Officine Gullo...
  • Page 37 Tighten to close the cap on top of the dispenser. ► Only cylinders issued by Wineemotion spa can be used because the means of attachment is customized. → The cylinder CANNOT BE RECHARGED! Manual of Use Officine Gullo...
  • Page 38 1. Replace the nitrogen cylinder when the high pressure gauge marks 10/5 bar. Below this threshold there is no guarantee for the correct operation of the dispenser. 2. Make sure the machine is turned off. 3. Close the supply valves of the regulator (A) Officine Gullo...
  • Page 39 (D). ). Release when the pressure gauges (E1- E2) show a value of 0 (zero). 6. Remove the pressure regulator and replace the cylinder (D). 7. Replace the gasket to prevent any leaks. Manual of Use Officine Gullo...
  • Page 40: Connections

    O (off ) position and make sure the voltage / frequency / power supplied match the values indicated on identification label. 5. Check the working conditions of the dispenser and check that there are no leaks (air, nitrogen / argon, etc.). Officine Gullo...
  • Page 41: Operation

    "B" in fig. 3. For proper use of the system and in accordance with hygiene rules, it is suggested to flush the suction tube whenever you replace a bottle. Manual of Use Officine Gullo...
  • Page 42: Piston Components For Bottle Positioning

    These parts together with the use of the spacer serve to ensure that the neck of the bottle applies the correct pressure on the seal of the dispenser to prevent leaks of gas (Nitrogen / Argon) and seal the bottle for preservation. Officine Gullo...
  • Page 43 Number Function bottle pad spacer piston head Manual of Use Officine Gullo...
  • Page 44 No. 1 and one on the left is the N ° 4/8: The keys instead go from left to right, one on the left is the N° 1 (lower dose) and one on the right is the N° 3 (higher dose): 17.2 C 1 2 3 Officine Gullo...
  • Page 45: Correct Positioning Of The Bottle

    (fig. 2): UP; the piston rises; DOWN; the piston drops; 6. First press the function button "DOWN" 7. Position the bottle according to fig. 8. Then press the function button "UP" Manual of Use Officine Gullo...
  • Page 46 5. Manually push the piston down to facilitate insertion of the bottle into the space provided. 6. Gently release the piston and check that the neck of the bottle fits snugly at the base of the tap seal. Officine Gullo...
  • Page 47 3. Select the nozzle where we inserted the bottle (Figure 2). 4. Once you have selected the location, the display will start a short animation of the bottle (Figure 3). 5. Wait for the end of the animation. Manual of Use Officine Gullo...
  • Page 48 G OK 17.2 C fig. 1 17.2 C fig. 2 Waiting load wine fig. 3 Officine Gullo...
  • Page 49: Dispensing

    17.2 C 2. Wait until the LED turns off before you remove the glass from below the nozzle. 3. At the end of dispensing mode all LED will return to off. Manual of Use Officine Gullo...
  • Page 50 ABSOLUTELY DO NOT REMOVE THE BOTTLE DURING USE Officine Gullo...
  • Page 51 Full bottle inserted: 1.00$ 2.00$ 3.00$ G AN Analyzing bottle: When the display indicates Bottle empty or absent: G EM, the machine will not dispense and will warn with the message on the display: NO GAS ► Manual of Use Officine Gullo...
  • Page 52 The dispenser responds to the glass door being open after approximately 90 seconds from initiation, after which the machine per- forms a P cycle (see function n. ) until the door is reinserted/closed. Indicates whether the gas valve is open or closed. Officine Gullo...
  • Page 53: Error States Of The System

    Display number one on the machine will show error screens 1 at a time, quickly and in sequence, after which the displays are sequenced at re- gular intervals between error and normal states, and the error screens will disappear once the error is fixed. Manual of Use Officine Gullo...
  • Page 54 • Select tap & Load • exit 13.4. Fridge Setting • Fridge C/F • Fridge Defrost • Fridge Evaporate • Fridge Temp Left • Fridge temp Right • Fridge Power • Reset Default • Exit & Save • Exit Officine Gullo...
  • Page 55 To exit press the two side buttons 0927 Calibrating together simultaneously until EXIT is shown 100 Mls EXIT key at the bottom left to and then press EXIT the menu and return to the previous main menu. Manual of Use Officine Gullo...
  • Page 56: Operation From The Main Main

    This function is used to calibrate the supply of the valves, allowing the release of the perfect amount preset from the “Wine Setting”. Calibrating Menu or 1 to 4 da 1 a 8 LOAD fig. 1 TASTE 100Mls? SAVE EXIT Officine Gullo...
  • Page 57 . SAVE It is used to save the calibration parameters. Exit Exit from the menu without saving. Manual of Use Officine Gullo...
  • Page 58 ► ► → → 0927 Calibrating (2) 100 Mls ? fig. 2 Number Function Base time for delivery of 100 Mls. Residual volume left in the bottle. The amount dispensed from the tap. Tap number currently being calibrated Officine Gullo...
  • Page 59: Display Setting

    Press the "P" key on the top left and enter the Main Menu, press the , key to activate the scrolling with the arrow keys and select Display Setting. Display Setting Select tap Disp. Backlight Disp. Contrast Disp. Bottle Led Exit & Save Manual of Use Officine Gullo...
  • Page 60: Wine Setting

    Exit the menu without saving 13.3 Wine Setting This function is to set the portions of the inserted wine. Wine Setting Select tap da 1 a 8 fig. 1 Glass volume 1 Glass volume 2 Glass volume 3 Bottle Volume Officine Gullo...
  • Page 61 Glass Volume 1 dispensed from button "1". Used to set the volume of product Glass Volume 2 dispensed from button “2”. Used to set the volume of product Glass Volume 3 dispensed from button “3”. Manual of Use Officine Gullo...
  • Page 62: Fridge Setting

    This function is used to set the parameters of the refrigeration system. → → Operation Press the "P" key on the top left and enter the Main Menu, press the , key to activate the scrolling with the arrow keys and select Fridge setting Officine Gullo...
  • Page 63 Function not available Fridge Temp. Right Used to reset the parameters to the default Reset Default state. Used to exit the menu and save the new Exit & Save parameters Exit the menu without saving Exit Manual of Use Officine Gullo...
  • Page 64 → If the Fridge Temp. Left falls below the minimum temperature that the machine can reach, the refrigeration automatically turns off, displaying its status as OFF. ► → Officine Gullo...
  • Page 65: Maintenance And Cleaning

    Wash the trays and clean the interior cabinet of the machine Clean the wine suction tubes by immersing it in a container of water. Thoroughly clean the dispensers to preserver the quality of the wine. Manual of Use Officine Gullo...
  • Page 66: Periodic Maintenance

    → d. Dispense the entire bottle of drinking water. → e. Replace the bottle of water with a bottle of wine and dispense once to expel the last bit of water left in the suction tube. Officine Gullo...
  • Page 67: Extraordinary Maintenance

    THE DISPENSER NOT OPERATING FOR A PERIOD OF MORE THAN 3 DAYS. PLEASE NOTE THAT THE USE OF SWEET OR PARTICULARLY AGED WINES MAY CAUSE THE FORMATION OF DEPOSITS IN VARIOUS DUCTS, INTENSIFY THE CLEANING IN THIS CASE. Manual of Use Officine Gullo...
  • Page 68 The refrigeration system is not Call technical support. working. Call technical support. Wine is dripping from the steel Wine sediments in the Perform cleaning maintenance tube of the dispenser dispenser. with citric acid solution, as described in the manual Officine Gullo...
  • Page 69: Ppe Required For Maintenance Personnel

    Children must be supervised to ensure that they do not play with the device. ► → Manual of Use Officine Gullo...
  • Page 70: Disposal Of The Machine

    Tel. +39 055 65 60 3324 +39 055 62 18 07 officinegullo.com | info@officinegullo.com declares under sole responsibility that the product DISPENSER AUTOMATIC FOR WINE model: QUATTRO (WND040) to which this declaration relates is in conformity with the following standards: Officine Gullo...
  • Page 71 State Members’ laws regarding the electric material destined to be used within certain voltage limits) - Electro-Magnetic Compatibility 2004/108 CE. (Directive regarding the approach of State Members’ laws concerning about electro-magnetic compatibility. Manual of Use Officine Gullo...
  • Page 72 • the diagnosis and elimination of any errors found in the SOFTWARE programmes (provided that the errors are recurrent and documented) by way of supply of new corrected versions of the software for the first 6 months; • the warranty shall include only the replacement of those defective Officine Gullo...
  • Page 73 Manual of Use Officine Gullo...
  • Page 74 Company in the course of, or in consequence of, such investigation. Without prejudice to the foregoing, the Company reserves the right to charge for travelling time and incidental expenses incurred in respect of attendance at your premises to investigate and rectify any problem Officine Gullo...
  • Page 75: Certifications Held By Series 3 Dispensers

    Purchaser will only be entitled to the benefit of any such warranty or guarantee as is given bythe supplier or service provider to the Company. WINEEMOTION S.p.A. Amministratore Delegato Riccardo Gosi Certifications held by SERIES 2 Dispensers International: Manual of Use Officine Gullo...
  • Page 76: Authorized Cleanind Products

    Storage Keep out of the reach of children, in a cool place, away from water, moisture, flame or sparks. Disposal of used product Dilute the used product with water before discharge into the sewer system. Officine Gullo...
  • Page 77 Chapitre 20 Lea atentamente el manual de usuario para la correcta preparación de la santificación. Capítulo 20 Do not use the product for other uses. cap. 20 Manual of Use Officine Gullo...
  • Page 78 Carcinogenicità NPT - No IARC - No OSHA - No ACGIH - No Patologie che aggravano i Una prolungata o ripetuta esposizione alle polveri può causare problemi polmonari sintomi Vedere anche la sezione 11 Officine Gullo...
  • Page 79 Successivamente alla raccolta, lavare con abbondante acqua la zona ed Una soluzione contenente 100-200 ppm di biossido di cloro non i materiali interessati necessita di neutralizzazione Una soluzione contenente 100-200 ppm di biossido di cloro non necessita di neutralizzazione Manual of Use Officine Gullo...
  • Page 80 13.1 Stabilità Prodotto stabile in condizioni normali 10.1 13.2 A contatto con l'acqua, umidità, vapore acqueo il prodotto rilascia Reazioni pericolose Officine Gullo 10.2 Biossido di Cloro gas 13.3 Sostanze incompatibili Evitare il contatto con acidi-alcali forti agenti riducenti-combustibili 10.3...
  • Page 81 Manual of Use Officine Gullo Gli imballaggi contaminati devono essere inviati a recupero o smaltimento nel rispetto Lo smaltimento deve essere affidato ad una società autorizzata alla gestione dei rifiuti, nel rispetto della normativa Imballaggi contaminati 13.2...
  • Page 82 Questa scheda annulla e sostituisce ogni edizione precedente. La Societa' inoltre non si assume responsabilita' per usi impropri e per comportamenti non conformi alle informazioni fornite. Officine Gullo...
  • Page 83 Protezione respiratoria respirare aerosol Protezione delle mani Evitare il contatto con la pelle, usare i guanti protettivi. Manual of Use Officine Gullo Protezione degli occhi Occhiali di sicurezza o visiera para-spruzzi. Protezione della pelle Indossare indumenti a protezione di contatti accidentali...
  • Page 84 DO NOT INDUCE VOMITING. Never give anything by mouth to an unconscious person. If vomiting occurs, keep head below hips to prevent aspiration. Section 5 - FIRE FIGHTING MEASURES FLASH POINT: Not Applicable AUTOIGNITION TEMP.: Not determined. Officine Gullo...
  • Page 85 CONDITIONS/HAZARDS TO AVOID: Heat. Exposure to light. INCOMPATIBILITY (Materials to Avoid): Strong acids or alkalis. Strong oxidizing agents. Reducing agents. INCOMPATIBILITY (Materials to Avoid): Strong acids or alkalis. Strong oxidizing agents. Reducing agents. Combustible materials. Combustible materials. Manual of Use Officine Gullo...
  • Page 86 UN/NA/PIN Number: UN2813 DOT Classification: 4.3 Dangerous when wet material DOT Proper Shipping Name: Water-reactive solid, N.O.S. (Contains sodium chlorite). Packing Group: III CANADIAN TRANSPORTATION OF DANGEROUS GOODS (TDG): TDG Classification: 5.1 Oxidizer, 4.3 Dangerous when wet material. Officine Gullo...
  • Page 87 Additionally, if this Material Safety Data Sheet is more than three years old, please contact this supplier at the phone number in Section 1 to make sure this sheet is current. supplier at the phone number in Section 1 to make sure this sheet is current. Manual of Use Officine Gullo...
  • Page 88: Sanikleen 512 We

    Storage Keep out of the reach of children, in a cool place, away from oxidizing or caustic substances. Disposal of used product Dilute the used product with water before discharge into the sewer system. Officine Gullo...
  • Page 89 BOTTLES WITH A SEALED CHILDPROOF CAP Material: High density polyethylene. Colour: Neutral - for alimentary uses. Cap can be unscrewed only by pushing and turning. Complete emptying is ensured by tilting the shoulders. Suitable for containing very fluid liquids. Manual of Use Officine Gullo...
  • Page 90 Se l'irritazione persiste, contattare un medico Contatto con gli occhi Lavare immediatamente con abbondante acqua anche sotto le palpebre per Officine Gullo almeno 15 minuti.Consultare immediatamente un medico Ingestione Somministrare prontamente un abbondante quantità di acqua o latte.
  • Page 91 Classe/Cifra Protezione delle mani Evitare il contatto con la pelle, usare i guanti protettivi. Protezione degli occhi Occhiali di sicurezza o visiera para-spruzzi. Manual of Use Officine Gullo Protezione della pelle Indossare indumenti a protezione di contatti accidentali...
  • Page 92 Questa scheda di sicurezza è la traduzione in lingua italiana della scheda originale in lingua inglese fornita Officine Gullo dal produttore. La scheda originale è a disposizione di chiunque intenda richiederla. In caso di controversie la scheda originale prevale su quella tradotta.
  • Page 93 RESPIRATORY PROTECTION: None required under normal use conditions. Avoid misting. VENTILATION REQUIREMENTS: Mechanical PROTECTIVE GLOVES: Neoprene type EYE PROTECTION: Safety glasses / goggles OTHER PROTECTIVE CLOTHING: Protective clothing as appropriate to minimize contact. Page 1 of 2 Manual of Use Officine Gullo...
  • Page 94 Since buyer's conditions of use of product are beyond ConSeal's control, ConSeal does not warrant any recommendations and information for the use of such products. ConSeal disclaims all other warranties including the implied warranty of merchantability and fitness for any particular purpose in connection with the use of its products. Officine Gullo...
  • Page 95 Wineemotion s.p.a Strada di Sant’Appiano 9/A - cap. 50021 Barberino Val d’ Elsa (FI) P.IVA 06231920486 | tel. +39 055 3985422 fax. +39 055 9029422 email. info@wineemotion.com - website. www.wineemotion.com MADE IN ITALY...
  • Page 96 en - us international V 1.1 - 10.18 Via Della Torricella 29, Antella, Bagno a Ripoli 50012 Florence - Italy Tel. +39 055 65 60 3324 / +39 055 62 18 07 Fax. +39 055 62 06 70 officinegullo.com | info@officinegullo.com...

Table of Contents