Innovative L500 Installation And Operating Manual

Multi-point vertically mounted liquid level float switch

Advertisement

Quick Links

M
M
o
o
M
M
o
o
Installation and Operating Manual
d d
e e
l l
d d
e e
l l
M
M
M
M
v
v
e e
r
r
t t
v
v
e e
r
r
t t
L L
L L
F F
l l
F F
l l
60 Great Hill Road
ph: 203-729-6434
L L
5 5
L L
5 5
u u
l l
t t
i i
- -
P P
u u
l l
t t
i i
- -
P P
i i
c c
a
a
l l
l l
y
y
i i
c c
a
a
l l
l l
y
y
i i
q
q
u u
i i
d d
L L
i i
q
q
u u
i i
d d
L L
o
o
a
a
t t
S S
w
w
o
o
a
a
t t
S S
w
w
www.innovativesensing.com
0 0
0 0
0 0
0 0
o
o
i i
n n
t t
o
o
i i
n n
t t
M
M
o
o
u u
n n
t t
M
M
o
o
u u
n n
t t
e e
v
v
e e
l l
e e
v
v
e e
l l
i i
t t
c c
h h
i i
t t
c c
h h
Naugatuck, CT 06770
fax: 203-729-6696
e e
d d
e e
d d

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Innovative L500

  • Page 1 Installation and Operating Manual 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com...
  • Page 2 Cautions alert the technician to special conditions that Innovative Solutions will repair or replace the control at no could injure personnel, damage equipment, or reduce cost to the purchaser (or owner) other than transportation.
  • Page 3: Table Of Contents

    mul ti-Point verticall y MOUNTED LIQUID mul ti-Point verticall y MOUNTED LIQUID LEVEL FLOAT SWITCH LEVEL FLOAT SWITCH Table of Contents 1.0 Installation 1.1 Unpacking ................1 1.2 Before You Begin .............1 1.2.1 Site Preparation.............1 1.2.2 Equipment and Tools ..........1 1.3 Mounting................2 1.3.1 Threaded Mounting..........2 1.4 Wiring .................2...
  • Page 4: Installation

    Installation This section provides detailed procedures for properly installing the Vertically Mounted Liquid Level Multi-Point Float Switch. Caution: If equipment is used in a manner not specified by manufacturer, protection provided by equipment may be impaired. Unpacking Unpack the instrument carefully. Inspect all units for dam- age.
  • Page 5: Mounting

    Mounting The Multi-Point Vertically Mounted Liquid Level Float Switch is available with a variety of threaded or flanged mountings. These devices can be installed from the bottom or top of the tank. The switches should be mounted in an area clear of turbulence or direct streams.
  • Page 6: Preventative Maintenance

    Preventive Maintenance Periodic inspections are a necessary means to keep your level control in good working order. This control is a safety device that protects the valuable equipment it serves. A systematic program of preventive maintenance should be implemented when the control is placed into service. If the following instructions are observed, your control will provide reliable protection of your equipment for many years.
  • Page 7: Reference Information

    Reference Information This section presents an overview of the operation of the Multi-Point Vertically Mounted Liquid Level Float Switch, including information on troubleshooting common problems, maintenance procedures, listings of agency approvals, and detailed physical, functional, and performance specifications. Description The Multi-Point Vertically Mounted Liquid Level Float Switches are float actuated devices designed for vertical mounting in a tank or process vessel through threaded or flanged connections.
  • Page 8: Unit Causes

    3.3.2 The Unit Causes If a thorough inspection of these possible conditions fails to locate the cause of the problem, proceed to a check of the switch mechanism. 1. Disconnect power to the level switch. 2. Use an electrical continuity checker to determine if the switch is electrically functional.
  • Page 9: Agency Approvals

    3.4 Agency Approvals AGENCY APPROVED MODEL FILE NUMBER AREA CLASSIFICATION L500 E203716 Recognized under UL508 motor controllers & NJ0T8 motor controllers Multi-Point Vertically Mounted Liquid Level Float Switch...
  • Page 10: Specifications

    Specifications 3.5.1 Float Specifications Min. Media Specific Float Materials Dimensions Temperature Pressure Gravity Polypropylene (hollow) 1.81” X 1.875” -40° to +150°F 50 psig 0.55 316 Stainless Steel 1.50” X 1.30” -40° to +300°F 120 psig 0.85 316 Stainless Steel 2” Ball -40°...
  • Page 11: Custom Configurator

    3.5.4 Custom Configurator - Actuation Dimensions Actuation Level Dimensions: A = 1-1/2” Minimum distance from actuation point to inside surface of tank or mounting pad. B = 3.0” Minimum distance between actuation levels C = 2.0” Minimum distance from end of unit to lowest actuation point D = 1/4”...
  • Page 12: Replacement Parts

    Replacement Parts ➀ ➁ ➂ Item Description Enclosure Float Retaining Clip or Collar Important: Contact factory for ordering assistance on all replacement parts. There are many options available to choose from. Multi-Point Vertically Mounted Liquid Level Float Switch...
  • Page 13: Product Configurator

    Product Configurator TECHNOLOGY TYPE Liquid level sensor SERIES 1/2” Diameter Stem IDENTIFIER Standard Product Custom Product MOUNTING SIZE No Mounting 1/4” NPT 3/8” NPT 1/2” NPT 3/4” NPT 1” NPT 1-1/4” NPT 1-1/2” NPT STEM / BODY MATERIAL Brass Polypropylene 316 SS Teflon®...
  • Page 14 Notes...
  • Page 15 ASSURED QUALITY & SERVICE COST LESS Service Policy Return Material Procedure Owners of Innovative Solutions controls may request the return So that we may efficiently process any materials that are returned, of a control or any part of a control for complete rebuilding or it is essential that a “Return Material Authorization”...

Table of Contents