Do you have a question about the AutoSwitch ON/OFF and is the answer not in the manual?
Questions and answers
Summary of Contents for Royal Exclusiv AutoSwitch ON/OFF
Page 1
Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de v1.0 Operating and maintenance instructions for AutoSwitch ON/OFF For all switchable outlets with capacitive sensor and delay release...
Richard-Byrd-Str. 7 // 50829 Cologne // Germany Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de Operating and maintenance instructions for AutoSwitch ON/OFF For all switchable outlets with capacitive sensor and delay release 0.1 Foreword 0.4 Operating and display elements The capacitive sensor of the switchable outlet recorded Self explanatory.
Page 3
skimmers oyal xclusiv umps & Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de For more information, please visit www.royal-exclusiv.de. Simply enter the part number or name into the search box or email: info@royal-exclusiv.de.
skimmers oyal xclusiv umps & Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de 1 Preliminary note 1.1 Symbols used • Operating elements are indicated as follows: Example: [OUT OFF] = Button “OUT OFF“�...
Page 5
• detects without contact metals, almost all plastics, glass, ceramics, wood, paper, oils, greases, water and all hydrous materials and indicates their presence by providing a switched signal skimmers oyal xclusiv umps & • automatic adjustment to the medium to be detected by means of programming Klaus Jansen // Richard-Byrd-Str.
skimmers oyal xclusiv umps & Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany 1: sensing face : nominal sensing range (see data sheet) Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 2: programming buttons A: distance = 8 mm info@royal-exclusiv.de // www.royal-exclusiv.de 3: plastic plate B: width of the mounting adapter = 36 mm...
Page 7
skimmers oyal xclusiv umps & Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de 4.3 Notes on laying of the connection cable ► Lay the cable as straight as possible and do not coil it� ►...
5.2 Unit versions with auto-detect On power up, unit types with auto-detect (types ���FAKG or ���FAOG���) detect skimmers oyal xclusiv umps automatically if the output is connected to L- (p switching) or to L+ (n switching)� & Klaus Jansen // Richard-Byrd-Str.
Page 9
Set the unit as normally open (output closes when the skimmers oyal xclusiv umps & tank is full): Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany ► Press [OUT OFF] for min� 2 s (max� 6 s)� Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de >...
Page 10
> For NO the LED lights, for NC it goes out� Set the unit as normally open (output closes when the skimmers oyal xclusiv umps & tank is full): Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany ► Press [OUT ON] for min� 6 s� Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 info@royal-exclusiv.de // www.royal-exclusiv.de...
pushbutton, the LED goes out� Set the unit as normally closed (output opens when the tank is full): skimmers oyal xclusiv umps & ► Press [OUT ON] for min� 6 s� Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany >...
You will find the IODDs necessary for the configuration of the IO-Link unit and detailed information about sensor values, diagnostic information and parameters skimmers oyal xclusiv umps in the overview table at www�ifm�com/uk/io-link� & Klaus Jansen // Richard-Byrd-Str. 7 // 50829 Cologne // Germany 7.5.3 Parameter setting tools Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622...
bodies� When replacing the sensor ensure that installation is done in the same way and a skimmers oyal xclusiv umps sensor with the same settings is used� & Klaus Jansen // It is not possible to repair the unit� Richard-Byrd-Str. 7 // 50829 Cologne // Germany Since 1 986 Fon +49(0)221/222886 0 // Fax +49(0)221/22288622 After use dispose of the unit in an environmentally friendly way in accordance with...
12. Manufacturer’s declaration 11.6. Claims against us become time-barred within a year after the initial delivery of the goods to the customer. The same applies to claims for damages regardless of their ju- Royal Exclusiv ® Titles against concerning the ridical cause.